<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>VESDA &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/vesda/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sat, 13 Oct 2018 07:32:38 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>VESDA &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>19&#8243; Rack c/w 4 Blanks</title>
		<link>http://fireandsafetywa.com.au/product/19-rack-c-w-4-blanks/</link>
				<pubDate>Sun, 07 Oct 2018 15:26:38 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/19-rack-c-w-4-blanks/</guid>
				<description><![CDATA[To compliment the VESDA range of detectors, displays and programmers in a 19 inch subrack enclosure is available.]]></description>
								<content:encoded><![CDATA[<p>To compliment the VESDA range of detectors, displays and programmers in a 19 inch subrack enclosure is available. The 19 inch rack enclosure is designed to house up to 12 display and/or programmer modules, VESDAnet sockets, or relay only modules<br />
in a wide variety of configurations to suit the particular requirements of a site where centralised control and monitoring of the VESDA system is required. VESDA Aspirating Smoke Detectors (ASD) are available in a wide range of configurations to suit the particular requirements of each site. The system is modular with Display and Programmer Modules located in the most convenient location. The backbone to this modularity is VESDAnet, a fault tolerant RS485 communications loop which links all elements of the VESDA system together.</p>
<p>Mounting Options<br />
Display and Programmer modules can be mounted in a Detector Enclosure, in a Remote Box or in a 19 inch subrack. A Hand-held programmer module is also available for temporary and convenient connection to the VESDA system. Details of these standard mounting options are given in the Detector, Display and Programmer Data sheets.</p>
<p>Relay Signalling<br />
Each Display Module can be configured to drive relays which can be used for reliable (fault tolerant) signalling of Fire and Fault conditions to external systems. Standard Display Modules can drive 7 relays while VESDA VLS Display Modules can be configured to drive 7 or 12 relays. Relay functionality is fully configurable according to site requirements.</p>
<p>19 inch Rack Enclosure<br />
19 inch subracks can be installed in glass fronted enclosures and are mounted on a swing frame for convenient connection of all the cables. Cable entry for 24 VDC power, VESDAnet connection and interfacing to the relays is provided by multiple knock-outs on all four sides of the box. 19 inch subracks and blank panels must be ordered separately. Each enclosure will accommodate up to 3 subracks. If utilising only 1 or 2 racks the VESDA Power Supply (VPS-100-US-xxx) can also be mounted in the enclosure.</p>
<p>Features<br />
&#8211; Dual hinged glass door provides easy access to VESDA modules and termination boards<br />
&#8211; Second door provides access to the termination boards<br />
&#8211; Designed for easy mounting<br />
&#8211; Multiple knock-outs for easy cable entry<br />
&#8211; Holds up to 3 subracks<br />
&#8211; Full size, lockable window and door</p>
<p>Technical Specifications<br />
Construction:<br />
&#8211; NEMA 1 Rating<br />
&#8211; 16 gauge cold roll steel<br />
&#8211; Fully welded and ground<br />
&#8211; Double knockouts<br />
&#8211; Continuous hinges with stainless steel pins<br />
&#8211; Full size window kit – lockable<br />
&#8211; Door – lockable (keyed alike with window)<br />
Mounting: Key hole mounting<br />
Finish: 2-part polyurethane – bake on textured finish<br />
Color: Light grey<br />
Locks: Keyed alike Chicago locks<br />
Blanking Plates:<br />
&#8211; 14 gauge cold roll steel<br />
&#8211; Light grey matching color<br />
&#8211; Single plate – 19 x 51/4 &#8221;<br />
&#8211; Double plate – 19 x 101/2&#8243;<br />
&#8211; Enclosure requires 4 10/32&#8243; screws for mounting 19 inch rack and/or blanking plates</p>
]]></content:encoded>
										</item>
		<item>
		<title>Emitter &#8211; High</title>
		<link>http://fireandsafetywa.com.au/product/emitter-high/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/emitter-high/</guid>
				<description><![CDATA[Open-area Smoke Imaging Detection Wire High Powered 24VDC Emitter, Allows to double the dection ranges of the Imager 80° (OSI-90)]]></description>
								<content:encoded><![CDATA[<p>Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical beam detection issues such as false alarm incidents and alignment difficulties.  OSID systems may be configured to protect a range of spaces, regardless of shape.  The protection zone or &#8220;fire web&#8221; is determined by the placement of OSID detectors.  Multi-emitter solutions provide a true 3D arrangement.</p>
<p>OSID innovatively combines two technologies to reliably detect smoke in large, open spaces by using two wavelengths of light to detect particles, the system in able to distinguish between particle sizes.  The shorter UV wavelength interacts strongly with both small and large particles, while the longer IR wavelength is affected predominantly by larger particles.  Dual-wavelength path loss measurement therefore enable the detector to provide repeatable smoke obscuration values, while rejecting the presense of dust particles or solid intruding objects.<br />
An optical imaging array in the oSID detector provides a wider viewing angle to locate and capture images.  Consequently, the system is easier to instal and align and can compensate for drift aused by natural shifts in building structures.  Optical filtering, high-speed image acquisition, and intelligent software algorithms also enable the OSID detector to process images and provide new levels of stability and sensitivity while providing high tolerance to high-level lighting variability.</p>
<p>Features<br />
OSID&#8217;s uncompromising performance is based on the patented use of digital imaging, dual-frequency beams and smart algorithms delivering:<br />
&#8211; Patented dual wavelength, UV &#038; IR, particle detection<br />
&#8211; CMOS Imager with wide viewing angles<br />
&#8211; Simple installation, commissioning and maintenance<br />
&#8211; High tolerance to vibration and structural movement<br />
&#8211; High tolerance to dust, fogging, steam, relections and object intrusion<br />
&#8211; High resistance to reflected sunlight<br />
&#8211; On-board log memory<br />
&#8211; Software tool for diagnostic purposes<br />
&#8211; Aesthetically discreet and 3D coverage<br />
&#8211; Long range up to 150m (492 ft.) with minimal free space </p>
<p>Specifications<br />
Emitter &#8211; Standard Power Wired at 24VDC<br />
Allows to double the detection ranges of the Imager 80° (OSID-90)<br />
Dimensions &#8211; 208 x 136 x 96 mm<br />
Emitter (wired) &#8211; 535g<br />
Area Coverage &#8211; 2,000 m2</p>
]]></content:encoded>
										</item>
		<item>
		<title>OSID Install Kit &#8211; Laser Tool, Test Filter, PC Cable, Cleaning Cloth, Manual</title>
		<link>http://fireandsafetywa.com.au/product/osid-install-kit-laser-tool-test-filter-pc-cable-cleaning-cloth-manual/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/osid-install-kit-laser-tool-test-filter-pc-cable-cleaning-cloth-manual/</guid>
				<description><![CDATA[Open-area Smoke Imaging Detection Installation Kit includes Laser Alignment Tool, Test Filter, PC Cable, Reflectors, and Manual]]></description>
								<content:encoded><![CDATA[<p>Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical` beam detection issues such as false alarm incidents and alignment difficulties.  OSID systems may be configured to protect a range of spaces, regardless of shape.  The protection zone or &#8220;fire web&#8221; is determined by the placement of OSID detectors.  Multi-emitter solutions provide a true 3D arrangement.</p>
<p>OSID innovatively combines two technologies to reliably detect smoke in large, open spaces by using two wavelengths of light to detect particles, the system in able to distinguish between particle sizes.  The shorter UV wavelength interacts strongly with both small and large particles, while the longer IR wavelength is affected predominantly by larger particles.  Dual-wavelength path loss measurement therefore enable the detector to provide repeatable smoke obscuration values, while rejecting the presense of dust particles or solid intruding objects.</p>
<p>Features<br />
OSID&#8217;s uncompromising performance is based on the patented use of digital imaging, dual-frequency beams and smart algorithms delivering:<br />
&#8211; Patented dual wavelength, UV &#038; IR, particle detection<br />
&#8211; CMOS Imager with wide viewing angles<br />
&#8211; Simple installation, commissioning and maintenance<br />
&#8211; High tolerance to vibration and structural movement<br />
&#8211; High tolerance to dust, fogging, steam, relections and object intrusion<br />
&#8211; High resistance to reflected sunlight<br />
&#8211; On-board log memory<br />
&#8211; Software tool for diagnostic purposes<br />
&#8211; Aesthetically discreet and 3D coverage<br />
&#8211; Long range up to 150m (492 ft.) with minimal free space </p>
<p>Specifications<br />
OSID Installation Kit includes laser alignment tool, test filter, PC cable, cleaning cloth, reflectors, and manual</p>
]]></content:encoded>
										</item>
		<item>
		<title>OSID Demo Kit &#8211; 2 x OSE‐SPW (with alkaline batteries), 1 x OSI‐90, 1 x OSID‐INST, in Carry Case with Mounting Plates.</title>
		<link>http://fireandsafetywa.com.au/product/osid-demo-kit-2-x-ose%e2%80%90spw-with-alkaline-batteries-1-x-osi%e2%80%9090-1-x-osid%e2%80%90inst-in-carry-case-with-mounting-plates/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/osid-demo-kit-2-x-ose%e2%80%90spw-with-alkaline-batteries-1-x-osi%e2%80%9090-1-x-osid%e2%80%90inst-in-carry-case-with-mounting-plates/</guid>
				<description><![CDATA[Open-area Smoke Imaging Detection Demo Kit consists of 2 X OSE-SP-01, 1 X OSI-90, 1 X OSID-INST and Mounting Plates, fitted in a rugged carry case.]]></description>
								<content:encoded><![CDATA[<p>Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical` beam detection issues such as false alarm incidents and alignment difficulties.  OSID systems may be configured to protect a range of spaces, regardless of shape.  The protection zone or &#8220;fire web&#8221; is determined by the placement of OSID detectors.  Multi-emitter solutions provide a true 3D arrangement.</p>
<p>OSID innovatively combines two technologies to reliably detect smoke in large, open spaces by using two wavelengths of light to detect particles, the system in able to distinguish between particle sizes.  The shorter UV wavelength interacts strongly with both small and large particles, while the longer IR wavelength is affected predominantly by larger particles.  Dual-wavelength path loss measurement therefore enable the detector to provide repeatable smoke obscuration values, while rejecting the presense of dust particles or solid intruding objects.</p>
<p>Features<br />
OSID&#8217;s uncompromising performance is based on the patented use of digital imaging, dual-frequency beams and smart algorithms delivering:<br />
&#8211; Patented dual wavelength, UV &#038; IR, particle detection<br />
&#8211; CMOS Imager with wide viewing angles<br />
&#8211; Simple installation, commissioning and maintenance<br />
&#8211; High tolerance to vibration and structural movement<br />
&#8211; High tolerance to dust, fogging, steam, relections and object intrusion<br />
&#8211; High resistance to reflected sunlight<br />
&#8211; On-board log memory<br />
&#8211; Software tool for diagnostic purposes<br />
&#8211; Aesthetically discreet and 3D coverage<br />
&#8211; Long range up to 150m (492 ft.) with minimal free space </p>
<p>Specifications<br />
OSID Demo Kit consists of 2 X OSE-SP-01, 1 X OSI-90, 1 X OSID-INST and Mounting Plates, fitted in a rugged carry case.</p>
]]></content:encoded>
										</item>
		<item>
		<title>FTDI Cable 1.5M</title>
		<link>http://fireandsafetywa.com.au/product/ftdi-cable-1-5m/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/ftdi-cable-1-5m/</guid>
				<description><![CDATA[FTDI Cable 1.5 Metres
Allows to connect to a PC and hence OSID Diagnostic SW to the Imager.  The FTDI cable can be extended with another 20m using a cable with an active USB amplifier.]]></description>
								<content:encoded><![CDATA[<p>Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical` beam detection issues such as false alarm incidents and alignment difficulties.  OSID systems may be configured to protect a range of spaces, regardless of shape.  The protection zone or &#8220;fire web&#8221; is determined by the placement of OSID detectors.  Multi-emitter solutions provide a true 3D arrangement.</p>
<p>OSID innovatively combines two technologies to reliably detect smoke in large, open spaces by using two wavelengths of light to detect particles, the system in able to distinguish between particle sizes.  The shorter UV wavelength interacts strongly with both small and large particles, while the longer IR wavelength is affected predominantly by larger particles.  Dual-wavelength path loss measurement therefore enable the detector to provide repeatable smoke obscuration values, while rejecting the presense of dust particles or solid intruding objects.<br />
An optical imaging array in the oSID detector provides a wider viewing angle to locate and capture images.  Consequently, the system is easier to instal and align and can compensate for drift aused by natural shifts in building structures.  Optical filtering, high-speed image acquisition, and intelligent software algorithms also enable the OSID detector to process images and provide new levels of stability and sensitivity while providing high tolerance to high-level lighting variability.</p>
<p>Features<br />
OSID&#8217;s uncompromising performance is based on the patented use of digital imaging, dual-frequency beams and smart algorithms delivering:<br />
&#8211; Patented dual wavelength, UV &#038; IR, particle detection<br />
&#8211; CMOS Imager with wide viewing angles<br />
&#8211; Simple installation, commissioning and maintenance<br />
&#8211; High tolerance to vibration and structural movement<br />
&#8211; High tolerance to dust, fogging, steam, relections and object intrusion<br />
&#8211; High resistance to reflected sunlight<br />
&#8211; On-board log memory<br />
&#8211; Software tool for diagnostic purposes<br />
&#8211; Aesthetically discreet and 3D coverage<br />
&#8211; Long range up to 150m (492 ft.) with minimal free space </p>
<p>Specifications<br />
FTDI Cable 1.5 Metres<br />
Allows to connect to a PC and hence OSID Diagnostic SW to the Imager.  The FTDI cable can be extended with another 20m using a cable with an active USB amplifier.</p>
]]></content:encoded>
										</item>
		<item>
		<title>Laser Alignment Tool</title>
		<link>http://fireandsafetywa.com.au/product/laser-alignment-tool/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/laser-alignment-tool/</guid>
				<description><![CDATA[Laser Alignment Tool
A unique alignment tool for fast alignment.  Aligns and locks the eyeball, and is able to activae Emitters with locked.]]></description>
								<content:encoded><![CDATA[<p>Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical` beam detection issues such as false alarm incidents and alignment difficulties.  OSID systems may be configured to protect a range of spaces, regardless of shape.  The protection zone or &#8220;fire web&#8221; is determined by the placement of OSID detectors.  Multi-emitter solutions provide a true 3D arrangement.</p>
<p>OSID innovatively combines two technologies to reliably detect smoke in large, open spaces by using two wavelengths of light to detect particles, the system in able to distinguish between particle sizes.  The shorter UV wavelength interacts strongly with both small and large particles, while the longer IR wavelength is affected predominantly by larger particles.  Dual-wavelength path loss measurement therefore enable the detector to provide repeatable smoke obscuration values, while rejecting the presense of dust particles or solid intruding objects.<br />
An optical imaging array in the oSID detector provides a wider viewing angle to locate and capture images.  Consequently, the system is easier to instal and align and can compensate for drift aused by natural shifts in building structures.  Optical filtering, high-speed image acquisition, and intelligent software algorithms also enable the OSID detector to process images and provide new levels of stability and sensitivity while providing high tolerance to high-level lighting variability.</p>
<p>Features<br />
OSID&#8217;s uncompromising performance is based on the patented use of digital imaging, dual-frequency beams and smart algorithms delivering:<br />
&#8211; Patented dual wavelength, UV &#038; IR, particle detection<br />
&#8211; CMOS Imager with wide viewing angles<br />
&#8211; Simple installation, commissioning and maintenance<br />
&#8211; High tolerance to vibration and structural movement<br />
&#8211; High tolerance to dust, fogging, steam, relections and object intrusion<br />
&#8211; High resistance to reflected sunlight<br />
&#8211; On-board log memory<br />
&#8211; Software tool for diagnostic purposes<br />
&#8211; Aesthetically discreet and 3D coverage<br />
&#8211; Long range up to 150m (492 ft.) with minimal free space </p>
<p>Specifications<br />
Laser Alignment Tool<br />
A unique alignment tool for fast alignment.  Aligns and locks the eyeball, and is able to activae Emitters with locked.</p>
]]></content:encoded>
										</item>
		<item>
		<title>OSID Emitter Environmental</title>
		<link>http://fireandsafetywa.com.au/product/osid-emitter-environmental/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/osid-emitter-environmental/</guid>
				<description><![CDATA[Emitter Environmental Housing
Custom designed IP 66, NEMA 4-4X protective and enironmental housings protect OSID Emitters from dust and water ingress in industrial environments.]]></description>
								<content:encoded><![CDATA[<p>Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical` beam detection issues such as false alarm incidents and alignment difficulties.  OSID systems may be configured to protect a range of spaces, regardless of shape.  The protection zone or &#8220;fire web&#8221; is determined by the placement of OSID detectors.  Multi-emitter solutions provide a true 3D arrangement.</p>
<p>OSID innovatively combines two technologies to reliably detect smoke in large, open spaces by using two wavelengths of light to detect particles, the system in able to distinguish between particle sizes.  The shorter UV wavelength interacts strongly with both small and large particles, while the longer IR wavelength is affected predominantly by larger particles.  Dual-wavelength path loss measurement therefore enable the detector to provide repeatable smoke obscuration values, while rejecting the presense of dust particles or solid intruding objects.<br />
An optical imaging array in the oSID detector provides a wider viewing angle to locate and capture images.  Consequently, the system is easier to instal and align and can compensate for drift aused by natural shifts in building structures.  Optical filtering, high-speed image acquisition, and intelligent software algorithms also enable the OSID detector to process images and provide new levels of stability and sensitivity while providing high tolerance to high-level lighting variability.</p>
<p>Features<br />
OSID&#8217;s uncompromising performance is based on the patented use of digital imaging, dual-frequency beams and smart algorithms delivering:<br />
&#8211; Patented dual wavelength, UV &#038; IR, particle detection<br />
&#8211; CMOS Imager with wide viewing angles<br />
&#8211; Simple installation, commissioning and maintenance<br />
&#8211; High tolerance to vibration and structural movement<br />
&#8211; High tolerance to dust, fogging, steam, relections and object intrusion<br />
&#8211; High resistance to reflected sunlight<br />
&#8211; On-board log memory<br />
&#8211; Software tool for diagnostic purposes<br />
&#8211; Aesthetically discreet and 3D coverage<br />
&#8211; Long range up to 150m (492 ft.) with minimal free space </p>
<p>Specifications<br />
Emitter Environmental Housing<br />
Custom designed IP 66, NEMA 4-4X protective and enironmental housings protect OSID Emitters from dust and water ingress in industrial environments.</p>
]]></content:encoded>
										</item>
		<item>
		<title>OSID Imager Environmental</title>
		<link>http://fireandsafetywa.com.au/product/osid-imager-environmental/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/osid-imager-environmental/</guid>
				<description><![CDATA[Imager Environmental Housing
Custom designed IP 66, NEMA 4-4X protective and enironmental housings protect OSID Imagers from dust and water ingress in industrial environments.]]></description>
								<content:encoded><![CDATA[<p>Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical` beam detection issues such as false alarm incidents and alignment difficulties.  OSID systems may be configured to protect a range of spaces, regardless of shape.  The protection zone or &#8220;fire web&#8221; is determined by the placement of OSID detectors.  Multi-emitter solutions provide a true 3D arrangement.</p>
<p>OSID innovatively combines two technologies to reliably detect smoke in large, open spaces by using two wavelengths of light to detect particles, the system in able to distinguish between particle sizes.  The shorter UV wavelength interacts strongly with both small and large particles, while the longer IR wavelength is affected predominantly by larger particles.  Dual-wavelength path loss measurement therefore enable the detector to provide repeatable smoke obscuration values, while rejecting the presense of dust particles or solid intruding objects.<br />
An optical imaging array in the oSID detector provides a wider viewing angle to locate and capture images.  Consequently, the system is easier to instal and align and can compensate for drift aused by natural shifts in building structures.  Optical filtering, high-speed image acquisition, and intelligent software algorithms also enable the OSID detector to process images and provide new levels of stability and sensitivity while providing high tolerance to high-level lighting variability.</p>
<p>Features<br />
OSID&#8217;s uncompromising performance is based on the patented use of digital imaging, dual-frequency beams and smart algorithms delivering:<br />
&#8211; Patented dual wavelength, UV &#038; IR, particle detection<br />
&#8211; CMOS Imager with wide viewing angles<br />
&#8211; Simple installation, commissioning and maintenance<br />
&#8211; High tolerance to vibration and structural movement<br />
&#8211; High tolerance to dust, fogging, steam, relections and object intrusion<br />
&#8211; High resistance to reflected sunlight<br />
&#8211; On-board log memory<br />
&#8211; Software tool for diagnostic purposes<br />
&#8211; Aesthetically discreet and 3D coverage<br />
&#8211; Long range up to 150m (492 ft.) with minimal free space </p>
<p>Specifications<br />
Imager Environmental Housing<br />
Custom designed IP 66, NEMA 4-4X protective and enironmental housings protect OSID Imagers from dust and water ingress in industrial environments.</p>
]]></content:encoded>
										</item>
		<item>
		<title>OSID Wire Guard</title>
		<link>http://fireandsafetywa.com.au/product/osid-wire-guard/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/osid-wire-guard/</guid>
				<description><![CDATA[Open-area Smoke Imaging Detection Wire Guard
A steel cage to protect Open-area Smoke Imaging Detection Imagers and Emitters from vandalism and accidental damage.]]></description>
								<content:encoded><![CDATA[<p>Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical` beam detection issues such as false alarm incidents and alignment difficulties.  OSID systems may be configured to protect a range of spaces, regardless of shape.  The protection zone or &#8220;fire web&#8221; is determined by the placement of OSID detectors.  Multi-emitter solutions provide a true 3D arrangement.</p>
<p>OSID innovatively combines two technologies to reliably detect smoke in large, open spaces by using two wavelengths of light to detect particles, the system in able to distinguish between particle sizes.  The shorter UV wavelength interacts strongly with both small and large particles, while the longer IR wavelength is affected predominantly by larger particles.  Dual-wavelength path loss measurement therefore enable the detector to provide repeatable smoke obscuration values, while rejecting the presense of dust particles or solid intruding objects.<br />
An optical imaging array in the oSID detector provides a wider viewing angle to locate and capture images.  Consequently, the system is easier to instal and align and can compensate for drift aused by natural shifts in building structures.  Optical filtering, high-speed image acquisition, and intelligent software algorithms also enable the OSID detector to process images and provide new levels of stability and sensitivity while providing high tolerance to high-level lighting variability.</p>
<p>Features<br />
OSID&#8217;s uncompromising performance is based on the patented use of digital imaging, dual-frequency beams and smart algorithms delivering:<br />
&#8211; Patented dual wavelength, UV &#038; IR, particle detection<br />
&#8211; CMOS Imager with wide viewing angles<br />
&#8211; Simple installation, commissioning and maintenance<br />
&#8211; High tolerance to vibration and structural movement<br />
&#8211; High tolerance to dust, fogging, steam, relections and object intrusion<br />
&#8211; High resistance to reflected sunlight<br />
&#8211; On-board log memory<br />
&#8211; Software tool for diagnostic purposes<br />
&#8211; Aesthetically discreet and 3D coverage<br />
&#8211; Long range up to 150m (492 ft.) with minimal free space </p>
<p>Specifications<br />
Open-area Smoke Imaging Detection Wire Guard<br />
A steel cage to protect Open-area Smoke Imaging Detection Imagers and Emitters from vandalism and accidental damage.</p>
]]></content:encoded>
										</item>
		<item>
		<title>OSID Anti Condensation Film for Emitter Pack 10</title>
		<link>http://fireandsafetywa.com.au/product/osid-anti-condensation-film-for-emitter-pack-10/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/osid-anti-condensation-film-for-emitter-pack-10/</guid>
				<description><![CDATA[Anti-condensation film for OSID Emitters
An easy applicable film that provides a long time resistance to condensation on the acrylic Emitter lens.]]></description>
								<content:encoded><![CDATA[<p>Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection, OSID provides a low-cost, reliable and easy-to-install solution that overcomes typical` beam detection issues such as false alarm incidents and alignment difficulties.  OSID systems may be configured to protect a range of spaces, regardless of shape.  The protection zone or &#8220;fire web&#8221; is determined by the placement of OSID detectors.  Multi-emitter solutions provide a true 3D arrangement.</p>
<p>OSID innovatively combines two technologies to reliably detect smoke in large, open spaces by using two wavelengths of light to detect particles, the system in able to distinguish between particle sizes.  The shorter UV wavelength interacts strongly with both small and large particles, while the longer IR wavelength is affected predominantly by larger particles.  Dual-wavelength path loss measurement therefore enable the detector to provide repeatable smoke obscuration values, while rejecting the presense of dust particles or solid intruding objects.<br />
An optical imaging array in the oSID detector provides a wider viewing angle to locate and capture images.  Consequently, the system is easier to instal and align and can compensate for drift aused by natural shifts in building structures.  Optical filtering, high-speed image acquisition, and intelligent software algorithms also enable the OSID detector to process images and provide new levels of stability and sensitivity while providing high tolerance to high-level lighting variability.</p>
<p>Features<br />
OSID&#8217;s uncompromising performance is based on the patented use of digital imaging, dual-frequency beams and smart algorithms delivering:<br />
&#8211; Patented dual wavelength, UV &#038; IR, particle detection<br />
&#8211; CMOS Imager with wide viewing angles<br />
&#8211; Simple installation, commissioning and maintenance<br />
&#8211; High tolerance to vibration and structural movement<br />
&#8211; High tolerance to dust, fogging, steam, relections and object intrusion<br />
&#8211; High resistance to reflected sunlight<br />
&#8211; On-board log memory<br />
&#8211; Software tool for diagnostic purposes<br />
&#8211; Aesthetically discreet and 3D coverage<br />
&#8211; Long range up to 150m (492 ft.) with minimal free space </p>
<p>Specifications<br />
Anti-condensation film for Emitters<br />
An easy applicable film that provides a long time resistance to condensation on the acrylic Emitter lens.</p>
]]></content:encoded>