<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Tone Generator &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/tone-generator/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:31:31 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Tone Generator &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ASE Door Kit</title>
		<link>http://fireandsafetywa.com.au/product/ase-door-kit/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/ase-door-kit/</guid>
				<description><![CDATA[4100ES-S1 ASE Door Kit]]></description>
								<content:encoded><![CDATA[<p>4100ES-S1 ASE Door Kit</p>
<p>FP0935 comprises:<br />
1 x 4U hinged door with ASE cover and barrel nuts fitted<br />
1 x 3 way &#038; 1 x 2 way connector for ASE<br />
1 x FP0740 FAS interface module with red, yellow and white wires<br />
1 x pair of red &#038; black wires for ASE to 4100ES-S1 dc power supply<br />
4 x M6 screws/washers/cage nuts for mounting door<br />
5 x Cable ties, adhesive cable tie holders for fixing ASE wiring<br />
1 x Green earth lead + nut, washer for door earth<br />
2 x M4 x 16 screws + washers for ASE mounting</p>
]]></content:encoded>
										</item>
		<item>
		<title>PPU/AIU Door Kit</title>
		<link>http://fireandsafetywa.com.au/product/ppu-aiu-door-kit/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/ppu-aiu-door-kit/</guid>
				<description><![CDATA[FP0937 comprises: 1x 4U hinged door &#038; spacer bracket, connector strip, label, &#038; wiring fitted 4x M6 screws/washers/cage nuts for mounting door 5x Cable ties, adhesive cable tie holders for fixing wiring 1x Green earth lead + nut, washer for door earth 4x PK screws, plastic spacers for mounting Cube ASE 4x M4 screws/washers for mounting the WA ASE.]]></description>
								<content:encoded><![CDATA[<p>4100ES-S1 WA/Cube ASE Door Kit</p>
<p>FP0937 comprises:<br />
1 x 4U hinged door &#038; spacer bracket, connector strip, label, &#038; wiring fitted<br />
4 x M6 screws/washers/cage nuts for mounting door<br />
5 x Cable ties, adhesive cable tie holders for fixing wiring<br />
1 x Green earth lead + nut, washer for door earth<br />
4 x PK screws, plastic spacers for mounting Cube ASE<br />
4 x M4 screws/washers for mounting the WA ASE.</p>
]]></content:encoded>
										</item>
		<item>
		<title>100W 8U T-GEN OWS 1986-3 BOWS</title>
		<link>http://fireandsafetywa.com.au/product/100w-8u-t-gen-ows-1986-3-bows/</link>
				<pubDate>Sun, 07 Oct 2018 13:27:09 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/100w-8u-t-gen-ows-1986-3-bows/</guid>
				<description><![CDATA[The VIGILANT Building Occupant Warning System (BOWS) is a self-contained AS 2220 or ISO 8201 Alert and Evacuate tone generator, with integral power supply, digitised speech messages, and PA microphone. It has been designed to connect directly to a fire alarm panel, but can also be used as a stand-alone unit. Zone-based non-emergency paging options, IP remote audio connectivity and multiple audio connectivity make the VIGILANT BOWS a versatile unit ideally suited to a variety of building occupant warning applications.]]></description>
								<content:encoded><![CDATA[<p>The VIGILANT Building Occupant Warning System (BOWS) is a self-contained AS 2220 or ISO 8201 Alert and Evacuate tone generator, with integral power supply, digitised speech messages, and PA microphone. It has been designed to connect directly to a fire alarm panel, but can also be used as a stand-alone unit. Zone-based non-emergency paging options, IP remote audio connectivity and multiple audio connectivity make the VIGILANT BOWS a versatile unit ideally suited to a variety of building occupant warning applications.</p>
<p>The VIGILANT BOWS provides a fully featured, yet cost-effective solution for small to medium sized buildings. It is available in three configurations: 50W audio output for smaller buildings (expandable to 2 x 50W outputs), 100W audio output, and 2 x 100W audio output (10A PSU). </p>
<p>For emergency situations it supports stand-alone operation with automatic change-over from the alert tone and spoken message, to the evacuate tone and a different message; plus operator controlled evacuation key switch and in-built microphone for making emergency public address announcements.</p>
<p>For everyday use it provides a background music input; zone-selectable paging options using the in-built microphone and a front panel zone selection switch, or a remote 4-zone paging  console with integrated microphone; and a remote audio input with a control input for external sources such as external paging, LAN connected audio-over-IP announcement, etc</p>
]]></content:encoded>
										</item>
		<item>
		<title>T-GEN / QE90 Microphone Flat 4-way plug (ECP9702 only)</title>
		<link>http://fireandsafetywa.com.au/product/t-gen-qe90-microphone-flat-4-way-plug-ecp9702-only/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/t-gen-qe90-microphone-flat-4-way-plug-ecp9702-only/</guid>
				<description><![CDATA[The hand held dynamic microphone is fitted with a press-to-talk button. It is suitable for plugging into T-GEN 50 and QE90 to provide emergency PA and recording of digitised speech message.]]></description>
								<content:encoded><![CDATA[<p>The hand held dynamic microphone is fitted with a press-to-talk button. It is suitable for plugging into T-GEN 50 and QE90 to provide emergency PA and recording of digitised speech message. Two models are available; ME0213 has a DIN plug for use on older QE90 ECP9002, and ME0290 has a 4-Way flat plug for use on T-GEN 50 and QE90 ECP9702.</p>
]]></content:encoded>
										</item>
		<item>
		<title>Isolation Amplifier, 100V, 50W</title>
		<link>http://fireandsafetywa.com.au/product/isolation-amplifier-100v-50w/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/isolation-amplifier-100v-50w/</guid>
				<description><![CDATA[The FP0875 Isolation Amplifier connects to an existing 100V speaker line and reproduces this signal at up to 50W load on a separate supervised 100V line. It is suitable for use with speech and music as well as with warning tones.]]></description>
								<content:encoded><![CDATA[<p>The FP0875 Isolation Amplifier connects to an existing 100V speaker line and reproduces this signal at up to 50W load on a separate supervised 100V line. It is suitable for use with speech and music as well as with warning tones. The 100V output line from the amplifier is electrically isolated from the input 100V line, so noise or other signals on the output line are kept separate and do not affect the input line.</p>
<p>The Isolation Amplifier requires a nominal supply of 27Vdc.</p>
<p>Specifications<br />
&#8211; Supply Voltage                19.6V to 28.8Vdc<br />
&#8211; Quiescent Current          57mA1<br />
&#8211; Active Current                   2.2A (50W @ 27Vdc)<br />
&#8211; Input Signal                      100V rms @ 1W max.<br />
&#8211; Output Voltage                 100V rms<br />
&#8211; Output Power                    50W rms2 / 25W3<br />
Dimensions<br />
 &#8211; Height     295 mm<br />
 &#8211; Width       240 mm<br />
 &#8211; Depth      80 mm</p>
]]></content:encoded>
										</item>
		<item>
		<title>50W 8U T-GEN Building OWS 1986-2 BOWS</title>
		<link>http://fireandsafetywa.com.au/product/50w-8u-t-gen-building-ows-1986-2-bows/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/50w-8u-t-gen-building-ows-1986-2-bows/</guid>
				<description><![CDATA[The VIGILANT Building Occupant Warning System (BOWS) is a self-contained AS 2220 or ISO 8201 Alert and Evacuate tone generator, with integral power supply, digitised speech messages, and PA microphone. It has been designed to connect directly to a fire alarm panel, but can also be used as a stand-alone unit. Zone-based non-emergency paging options, IP remote audio connectivity and multiple audio connectivity make the VIGILANT BOWS a versatile unit ideally suited to a variety of building occupant warning applications.]]></description>
								<content:encoded><![CDATA[<p>The VIGILANT Building Occupant Warning System (BOWS) is a self-contained AS 2220 or ISO 8201 Alert and Evacuate tone generator, with integral power supply, digitised speech messages, and PA microphone. It has been designed to connect directly to a fire alarm panel, but can also be used as a stand-alone unit. Zone-based non-emergency paging options, IP remote audio connectivity and multiple audio connectivity make the VIGILANT BOWS a versatile unit ideally suited to a variety of building occupant warning applications.</p>
<p>The VIGILANT BOWS provides a fully featured, yet cost-effective solution for small to medium sized buildings. It is available in three configurations: 50W audio output for smaller buildings (expandable to 2 x 50W outputs), 100W audio output, and 2 x 100W audio output (10A PSU). </p>
<p>For emergency situations it supports stand-alone operation with automatic change-over from the alert tone and spoken message, to the evacuate tone and a different message; plus operator controlled evacuation key switch and in-built microphone for making emergency public address announcements.</p>
<p>For everyday use it provides a background music input; zone-selectable paging options using the in-built microphone and a front panel zone selection switch, or a remote 4-zone paging  console with integrated microphone; and a remote audio input with a control input for external sources such as external paging, LAN connected audio-over-IP announcement, etc</p>