<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Smoke &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/smoke/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Tue, 02 Aug 2022 04:48:14 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Smoke &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Optical Sensor &#8211; TrueAlarm</title>
		<link>http://fireandsafetywa.com.au/product/optical-sensor-truealarm/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/optical-sensor-truealarm/</guid>
				<description><![CDATA[The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics]]></description>
								<content:encoded><![CDATA[<p>The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics. Used in conjunction with the Simplex 4100 panel, the 9714E has a high degree of false alarm immunity thanks to advanced algorithms. The detector mounts on the 4098-9789 addressable base or 4098-9794 sounder base. An optional remote LED can also be fitted.</p>
<p>Specifications<br />
&#8211; Operating Voltage                           24 to 40Vdc*<br />
&#8211; Quiescent Current (max)               100µA<br />
&#8211; Alarm Current-relay active              24mA<br />
&#8211; External Output Drive (max)           5mA<br />
&#8211; Relative Humidity                             10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                     -9°C to +50°C<br />
&#8211; Air Velocity                                         0 to 610m/min<br />
&#8211; Sensitivity                                          4 to 6% Obs/m<br />
&#8211; ActivFire Listed                                 afp-1225</p>
<p>* MAPNET II or IDNet auto select w/data</p>
]]></content:encoded>
										</item>
		<item>
		<title>Photo / Heat Multi Sensor &#8211; TrueAlarm</title>
		<link>http://fireandsafetywa.com.au/product/photo-heat-multi-sensor-truealarm/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/photo-heat-multi-sensor-truealarm/</guid>
				<description><![CDATA[TrueAlarm multi-sensor 4098-9754EA combines the TrueAlarm photoelectric smoke sensor with a fast-acting and accurate TrueAlarm thermal sensor to provide both features in a single sensor/base assembly.]]></description>
								<content:encoded><![CDATA[<p>TrueAlarm multi-sensor 4098-9754EA combines the TrueAlarm photoelectric smoke sensor with a fast-acting and accurate TrueAlarm thermal sensor to provide both features in a single sensor/base assembly. Analog information from each sensor is digitally communicated to the control panel where it is analysed. Photoelectric sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor’s present value against its average value. Thermal<br />
data is processed to look for absolute or rate-of-rise temperature as desired. Monitoring each photoelectric sensor’s average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging. The result is a significant reduction in false or nuisance alarms caused by shifts in sensitivity</p>
<p>Specifications<br />
4098-9754E<br />
&#8211; Operating Voltage (MAPNET II)          24 to 40Vdc<br />
&#8211; Operating Current (MAPNET II)          500µA (max)<br />
&#8211; Relative Humidity                                  10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                          0 to +50°C<br />
&#8211; Sensitivity (at c.i.e.)                               4 and 5%Obs/m<br />
with 4098-9795E<br />
&#8211; Alarm Current (sounder on)                17mA @ 24Vdc<br />
&#8211; Sounder Power (external)                    18 to 32Vdc<br />
&#8211; Sound Pressure Level                          88dBA @ 3m<br />
 -ActivFire Listed (MAPNET)                    afp-1361</p>
<p>*MAPNET II or IDNet auto select w/data</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX 801PHEx Intrinsically Safe (I.S) Photoelectric &#038; Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801phex-intrinsically-safe-i-s-photoelectric-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801phex-intrinsically-safe-i-s-photoelectric-heat-detector/</guid>
				<description><![CDATA[The 801PHEx Intrinsically Safe Optical Smoke &#038; Heat Detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the optical smoke and heat elements of the detector.]]></description>
								<content:encoded><![CDATA[<p>The 801PHEx Intrinsically Safe Optical Smoke &#038; Heat Detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the optical smoke and heat elements of the detector. Software within the controller interprets the returned optical and heat values to raise an alarm or other appropriate response according to the type of programmed configuration. </p>
<p>The mode of detector may be:<br />
&#8211; Optical smoke only detector (High/ Normal/Low)<br />
&#8211; HPO smoke detector (sensitivity High, Normal or Low)<br />
&#8211; Heat only rate-of-rise (A1R) detector (no sensitivity selection)<br />
&#8211; Heat fixed temperature 60°C (A2S) (no sensitivity selection)<br />
&#8211; Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60°C (A2S)<br />
&#8211; HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60°C (A2S)</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus. </p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                 18 to 24Vdc<br />
&#8211; Queiscent Current                 400µA (max.)<br />
&#8211; Alarm Current                         3.5mA (max.)<br />
&#8211; Operating Tempearture        -25°C to +70°C<br />
&#8211; Relative Humidity                   10% to 95% (non-cond.)<br />
&#8211; FPANZ Listed                          VF/351<br />
&#8211; IECEX Certificate                    IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>TYCO 614CH Conventional Carbon Monoxide Detector</title>
		<link>http://fireandsafetywa.com.au/product/tyco-614ch-conventional-carbon-monoxide-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/tyco-614ch-conventional-carbon-monoxide-detector/</guid>
				<description><![CDATA[The 614CH fire detector provides very early warning of slow smouldering fires. The CO fire detector is well suited to many applications where heat detection is insufficient but smoke detection causes unwanted alarms. As CO travels more freely than smoke, the positioning of CO fire detectors is more flexible]]></description>
								<content:encoded><![CDATA[<p>The 614CH fire detector provides very early warning of slow smouldering fires. The CO fire detector is well suited to many applications where heat detection is insufficient but smoke detection causes unwanted alarms.  As CO travels more freely than smoke, the positioning of CO fire detectors is more flexible.</p>
<p>This feature is particularly useful in large complex structures such as atria and warehouses, where positioning of smoke detectors is difficult. The 614CH has an additional mode of operation as a Class A1R  combined rate-of-rise and 60°C fixed temperature heat detector to supplement the CO detector mode to permit the detector to react to a wider range of fire types. </p>
<p>Although the 614CH has a rated service life of 10 years, in orderc for the 614CH to provide the intended level of fire detection, the detector should be checked for calibration 5 years after installation (or 5 years after re-installation following service) or within 7 years of the date of manufacture.</p>
<p>Specifications<br />
&#8211; Operating Voltage                   10 to 33Vdc<br />
&#8211; Quiescent Current                   55µA (max.)<br />
&#8211; Alarm Current                           3.2 to 67mA (50°C)*<br />
&#8211; Alarm State Voltage                 2.5 to 7.4Vdc<br />
&#8211; Alarm Threshold                      38ppm CO<br />
&#8211; Ext. Powered Load (max.)      50mA, 28Vdc<br />
&#8211; Remote Indicator                     E500 Mk2 Series<br />
&#8211; Relative Humidity                    15 to 90% (n/cond)<br />
&#8211; Ambient Temp                          0 to +50°C<br />
&#8211; Dimensions (incl. base)        127 dia x 54H (mm)<br />
&#8211; Weight                                        200g with base<br />
&#8211; FPANZ Listed                            VF/345</p>
<p>*1. 3.2mA min. for LED visibility. Max. current must be externally limited</p>
]]></content:encoded>
										</item>
		<item>
		<title>TYCO 614P Conventional Photo Optical Detector</title>
		<link>http://fireandsafetywa.com.au/product/tyco-614p-conventional-photo-optical-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/tyco-614p-conventional-photo-optical-detector/</guid>
				<description><![CDATA[The 614P is capable of detecting the visible smoke produced by materials which smoulder or burn slowly, i.e. soft furnishings, plastic foam etc. or ‘smoke’ produced by overheated but unburnt PVC.]]></description>
								<content:encoded><![CDATA[<p>The 614P is capable of detecting the visible smoke produced by materials which smoulder or burn slowly, i.e. soft furnishings, plastic foam etc. or ‘smoke’ produced by overheated but unburnt PVC. These detectors are particularly suitable for general applications and areas where cable overheating may occur; electrical services areas. The novel design of the asymmetrical sampling chamber and signal processing techniques stop unwanted alarms caused by very small insects. Smoke entering the sampling chamber scatters the infrared light pulses onto a photodiode. These pulses are converted to an electrical signal that is compared against a preset alarm level.</p>
<p>Specifications<br />
&#8211; Operating Voltage 10 to 33Vdc<br />
&#8211; Quiescent Current 60µA<br />
&#8211; Alarm Current (max.)* 0.7 to 67mA (55°C)<br />
0.7 to 60mA (70°C)<br />
&#8211; Alarm State Voltage 2.5 to 7.4V<br />
&#8211; Ext. Powered Load (max.) 50mA. 28Vdc<br />
&#8211; Sensitivity (AS7240.7-2004) 4%Obs/m<br />
&#8211; Remote Indicator E500 Mk2 Series<br />
&#8211; Relative Humidity 10% to 95% (n/cond)<br />
&#8211; Ambient Temperature -20°C to +70°C<br />
&#8211; Dimensions (incl. base) 127 dia x 54H (mm)<br />
&#8211; Weight 188g with base<br />
&#8211; ActivFire Listed afp-1715<br />
&#8211; FPANZ Listed VF/344</p>
<p>*Max. current must be externally limited</p>
]]></content:encoded>
										</item>
		<item>
		<title>MR601TEX High Performance Optical Intrinsically Safe</title>
		<link>http://fireandsafetywa.com.au/product/mr601tex-high-performance-optical-intrinsically-safe/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mr601tex-high-performance-optical-intrinsically-safe/</guid>
				<description><![CDATA[The MR601TEX has been developed to overcome  the slower response of the optical detectors to hot burning fires, by increasing the sensitivity of the optical detector when it is associated with a rapid change in temperature.]]></description>
								<content:encoded><![CDATA[<p>The MR601TEX has been developed to overcome  the slower response of the optical detectors to hot burning fires, by increasing the sensitivity of the optical detector when it is associated with a rapid change in temperature. In this way it is intended to become a detector which can cover some of the risks currently covered by ion chamber detectors. Smoke detectors will not detect burning alcohol or other clean-burning liquids which do not generate smoke particles. </p>
<p>Specifications<br />
&#8211; Operating Voltage              16 to 28Vdc<br />
&#8211; Operating Current              110 µA (max.)<br />
&#8211; Alarm Current                      30mA @ 16Vdc<br />
&#8211; Operating Temp                  -20°C to +70°C<br />
&#8211; Relative Humidity                95% (non-cond.)<br />
&#8211; Dimensions                        109 dia x 43 H mm<br />
&#8211; Weight                                  128g<br />
&#8211; ATEX Certificate                  BAS01ATEX11134X.<br />
&#8211; IECEX Certificate                BAS 07.0056X</p>
]]></content:encoded>
										</item>
		<item>
		<title>814P MX Photo Optical Smoke Detector</title>
		<link>http://fireandsafetywa.com.au/product/814p-mx-photo-optical-smoke-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/814p-mx-photo-optical-smoke-detector/</guid>
				<description><![CDATA[The 814P is a state-of-the-art smoke detector using a photoelectric sensor which, in conjunction with the MX fire indicator panel (CIE), suits most fire detection applications including smoke management systems. The smoke sensors incorporate a unique]]></description>
								<content:encoded><![CDATA[<p>The 814P is a state-of-the-art smoke detector using a photoelectric sensor which, in conjunction with the MX fire indicator panel (CIE), suits most fire detection applications including smoke management systems. The smoke sensors incorporate a unique<br />
“mousehole” design optical chamber with superior signal to noise ratio providing high resilience to dust and dirt which means reduced service costs. A unique chamber cover actually draws slow moving smoke into the chamber to provide a more responsive detector.</p>
<p>The 814PH adds a heat sensor which allows a full set of detection modes to be implemented in the MX CIE. The heat sensor monitors temperature and has been tested as a detector in its own right. The 814P &#038; 814PH have all the features of MX VIRTUAL detectors including self verification, temperature and smoke level indication and superior service functions.</p>
<p>Specifications<br />
&#8211; Operating Voltage           20 to 40Vdc<br />
&#8211; Quiescent Current          275µA (typ.)<br />
&#8211; Alarm Current                  10mA with LED on<br />
&#8211; Remote Indicator            Tyco E500 Mk2<br />
&#8211; Relative Humidity            10% to 95% (n/cond)<br />
&#8211; Ambient Temp.                &#8211; 25°C to +70°C<br />
&#8211; Dimensions                     109 dia x 43h mm<br />
&#8211; Weight                               76g<br />
&#8211; ActivFire Listed                afp-1699<br />
&#8211; FPANZ Listed                  VF/342</p>
]]></content:encoded>
										</item>
		<item>
		<title>814PH MX Photo &#038; Heat Multi Detector c/w coating Thermistor (UK)</title>
		<link>http://fireandsafetywa.com.au/product/814ph-mx-photo-heat-multi-detector-c-w-coating-thermistor-uk/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/814ph-mx-photo-heat-multi-detector-c-w-coating-thermistor-uk/</guid>
				<description><![CDATA[The 814P is a state-of-the-art smoke detector using a photoelectric sensor which, in conjunction with the MX fire indicator panel (CIE), suits most fire detection applications including smoke management systems. The smoke sensors incorporate a unique]]></description>
								<content:encoded><![CDATA[<p>The 814P is a state-of-the-art smoke detector using a photoelectric sensor which, in conjunction with the MX fire indicator panel (CIE), suits most fire detection applications including smoke management systems. The smoke sensors incorporate a unique<br />
“mousehole” design optical chamber with superior signal to noise ratio providing high resilience to dust and dirt which means reduced service costs. A unique chamber cover actually draws slow moving smoke into the chamber to provide a more responsive detector.</p>
<p>The 814PH adds a heat sensor which allows a full set of detection modes to be implemented in the MX CIE. The heat sensor monitors temperature and has been tested as a detector in its own right. The 814P &#038; 814PH have all the features of MX VIRTUAL detectors including self verification, temperature and smoke level indication and superior service functions.</p>
<p>Specifications<br />
&#8211; Operating Voltage           20 to 40Vdc<br />
&#8211; Quiescent Current          275µA (typ.)<br />
&#8211; Alarm Current                  10mA with LED on<br />
&#8211; Remote Indicator            Tyco E500 Mk2<br />
&#8211; Relative Humidity            10% to 95% (n/cond)<br />
&#8211; Ambient Temp.                &#8211; 25°C to +70°C<br />
&#8211; Dimensions                     109 dia x 43h mm<br />
&#8211; Weight                               76g<br />
&#8211; ActivFire Listed                afp-1424<br />
&#8211; FPANZ Listed                  VF/335</p>
]]></content:encoded>
										</item>
		<item>
		<title>814I Ionisation Smoke Detector</title>
		<link>http://fireandsafetywa.com.au/product/814i-ionisation-smoke-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/814i-ionisation-smoke-detector/</guid>
				<description><![CDATA[Tyco 814I detectors are offered for old specifications which still call for ionisation smoke detectors. The 814CH and 814PH detectors offer improved performance and lower false alarms for most smoke detection applications.]]></description>
								<content:encoded><![CDATA[<p>Tyco 814I detectors are offered for old specifications which still call for ionisation smoke detectors. The 814CH and 814PH detectors offer improved performance and lower false alarms for most smoke detection applications. The 814I nevertheless offers reliable detection of visible and invisible fire aerosols using a dual ionisation chamber in which the air is ionised by a single radioactive source.</p>
<p>In combination with the SmartSense algorithm, the 814I provides early detection of hot smouldering and flaming fires, such as wood, paper etc. Warning: these detectors contain a small amount of radioactive material (typically <33.3kBq Americium 241). They are safe when used as prescribed. Handling, transport and disposal must be done in accordance with Health Department  regulations.

Specifications
- Operating Voltage                          20 to 40Vdc
- Quiescent Current (typical)          330µA
- Alarm Current (max.)                     10mA with LED on
- Radioactive Source                       33.3kBq Am241
- Remote Indicator                           Tyco E500 Mk2
- Relative Humidity                           10% to 95% (n/cond)
- Ambient Temperature                   -25°C to +70°C
- Airflow (max.)                                  2.5 m/sec
- Dimensions                                    109 dia x 43H mm
- Weight                                              81g
- ActivFire Listed                                afp-1426
- FPANZ Listed                                  VF/336
</p>
]]></content:encoded>
										</item>
		<item>
		<title>850PH MX Addr Photo Heat Detector c/w Isolator</title>
		<link>http://fireandsafetywa.com.au/product/850ph-mx-addr-photo-heat-detector-c-w-isolator/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/850ph-mx-addr-photo-heat-detector-c-w-isolator/</guid>
				<description><![CDATA[With its ability to detect a wide range of fires from flaming to smouldering types, the 850PH combined smoke and heat multi-sensor detector is the preferred choice for a range of applications including industrial, retail and office environments.]]></description>
								<content:encoded><![CDATA[<p>With its ability to detect a wide range of fires from flaming to smouldering types, the 850PH combined smoke and heat multi-sensor detector is the preferred choice for a range of applications including industrial, retail and office environments. It can operate in a  number of approved modes and sensitivities that can be dynamically selected to suit different environmental conditions. The heat sensor monitors rate-of-rise and fixed temperature and has been tested as a fire detector in its own right.</p>
<p>Specifications<br />
&#8211; Operating Voltage                     20 to 40Vdc<br />
&#8211; Quiescent Current                    330µA (typ.)<br />
&#8211; Ambient Temperature              -25°C to +70°C<br />
&#8211; Relative Humidity                     10% to 95% (non-cond)<br />
&#8211; Dimensions                              109 dia x 43h mm<br />
&#8211; Weight                                         76g<br />
&#8211; ActivFire Listed                             afp-2930<br />
&#8211; FPANZ Listed                               VF/363</p>