<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Simplex &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/simplex/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:32:05 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.21</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Simplex &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>IDNet Relay IAM with Unsupervised Input  (Uses RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/idnet-relay-iam-with-unsupervised-input-uses-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/idnet-relay-iam-with-unsupervised-input-uses-raco232-lid/</guid>
				<description><![CDATA[The 4090-9119 allows a 4100ES IDNet communication channel to monitor an unsupervised input contact with one point and control an output relay with the other point, yet occupy a single address]]></description>
								<content:encoded><![CDATA[<p>The 4090-9119 allows a 4100ES IDNet communication channel to monitor an unsupervised input contact with one point and control an output relay with the other point, yet occupy a single address. The input circuit and relay operation are controlled independently and may be disabled separately. Module power is supplied from the IDNet communications channel eliminating the need for separate power wiring. The address is set by DIP switch under the re-sealable label.</p>
<p>Specifications<br />
&#8211; Comms Power                           24 to 40Vdc w/data*<br />
&#8211; Relay Contact Ratings SPDT<br />
    Non power limited                    0.5A @120VAC**<br />
                                                         0.25A@120VAC***<br />
     Power limited                           2A@30Vdc**<br />
                                                         1A@30Vdc***<br />
&#8211; Input                                              N/O, dry contacts<br />
&#8211; Dimensions (HWD)                   105 x 105 x 35 mm<br />
&#8211; Ambient Temperature               0 to +49°C<br />
&#8211; Relative Humidity                       10% to 95% (n/c)</p>
<p>*      IDNet communications with data<br />
**    Resistive Load<br />
***   Inductive Load<br />
Note: Loop powered 2 wire device</p>
]]></content:encoded>
										</item>
		<item>
		<title>IDNet 6 Point I/O Module (4 I/Ps + 2 relay O/Ps) (Uses RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/idnet-6-point-i-o-module-4-i-ps-2-relay-o-ps-uses-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/idnet-6-point-i-o-module-4-i-ps-2-relay-o-ps-uses-raco232-lid/</guid>
				<description><![CDATA[The 4090-9120 allows 4100ES IDNet communication channel to monitor four T-sense input circuits and control two output relays from a single module requiring a single address.]]></description>
								<content:encoded><![CDATA[<p>The 4090-9120 allows 4100ES IDNet communication channel to monitor four T-sense input circuits and control two output relays from a single module requiring a single address. Power is supplied by a separate 24Vdc connection to a listed fire alarm power  supply. The input circuits and output relay operation are controlled independently and may be disabled separately. Point association is determined at the 4100ES host panel. At the 4100ES, the device address is designated as a single hardware location. Each of the four input circuits monitors for continuity to an end-of-line resistor and can differentiate between a short circuit contact closure and a current limited contact closure. Two input supervision resistors are required per T-sense input.</p>
<p>Specifications<br />
&#8211; Comms Power                       24 to 40Vdc w/data*<br />
&#8211; Operating Voltage                  18 to 32Vdc<br />
&#8211; Operating Current                  30mA@24Vdc<br />
&#8211; Relay Contact Ratings SPDT<br />
   Non-power limited                 0.5A @120VA**<br />
                                                      0.25A@120VAC***<br />
&#8211; Power limited                           2A@30Vdc**<br />
                                                      1A@30Vdc***<br />
&#8211; Supervision Resistor              6k8 Ohm 0.5W<br />
&#8211; Current Limited Operation     1k8/4k7 0.5W<br />
&#8211; Input                                            N/O, dry contacts<br />
&#8211; LED Output                                24Vdc (external PSU)<br />
&#8211; Dimensions (HWD)                 105 x 105 x 35 mm<br />
&#8211; Ambient Temperature             0 to +49°C<br />
&#8211; Relative Humidity                     10% to 90% (n/c)</p>
<p>*     IDNet communications with data<br />
**   Resistive Load<br />
***  Inductive Load<br />
Note: 4 wire device; requires separate 24Vdc and IDNet communication loop</p>
]]></content:encoded>
										</item>
		<item>
		<title>Addressable MCP Mounting Box</title>
		<link>http://fireandsafetywa.com.au/product/addressable-mcp-mounting-box/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/addressable-mcp-mounting-box/</guid>
				<description><![CDATA[Red surface mounting back box (for indoor callpoints) with terminals fitted.]]></description>
								<content:encoded><![CDATA[<p>Red surface mounting back box (for indoor callpoints) with terminals fitted.</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Roof Space&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-roof-space/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-roof-space/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Concealed Space&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-concealed-space/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-concealed-space/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Cupboard&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-cupboard/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-cupboard/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm Base with Remote LED O/P</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</guid>
				<description><![CDATA[TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds.]]></description>
								<content:encoded><![CDATA[<p>TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds. Since TrueAlarm detectors use the same base, different detector types can be easily interchanged to meet specific location requirements, for example, during building construction, or when conditions are temporarily dusty. Instead of covering the smoke  detectors(causing them to be disabled), heat detectors may be installed without reprogramming the CIE. Although the CIE will indicate an incorrect detector type, the heat detector will operate at a default sensitivity maintaining building protection at that location. </p>
<p>The 4098-9789EAP can be used in areas that may experience an increased moisture level, eg under eaves</p>
<p>Specifications<br />
&#8211; Operating Voltage                   24 to 40Vdc*<br />
&#8211; Quiescent Current (max)       400µA<br />
&#8211; Alarm Current (max)               3.2mA<br />
&#8211; Relative Humidity                    10% to 95% (n/cond)<br />
&#8211; Ambient Temperature             0 to +55°C<br />
&#8211; ActivFire Listed                         afp-1225 &#038; 1246</p>
<p>* MAPNET II or IDNet auto select</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Room&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-room/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-room/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm Base with Sounder</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</guid>
				<description><![CDATA[The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics.]]></description>
								<content:encoded><![CDATA[<p>The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics. Used in  conjunction with the Simplex 4100 panel, the 9714E has a high degree of false alarm immunity thanks to advanced algorithms. The detector mounts on the 4098-9789 addressable base or 4098-9794 sounder base. An optional remote LED can also be fitted.</p>
<p>Specifications<br />
&#8211; Operating Voltage                      24 to 40Vdc*<br />
&#8211; Quiescent Current (max)          100µA<br />
&#8211; Alarm Current-relay active         24mA<br />
&#8211; External Output Drive (max)      5mA<br />
&#8211; Relative Humidity                        10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                -9°C to +50°C<br />
&#8211; Air Velocity                                    0 to 610m/min<br />
&#8211; Sensitivity                                      4 to 6% Obs/m<br />
&#8211; ActivFire Listed                            afp-1225</p>
<p>* MAPNET II or IDNet auto select w/data</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Return Air&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-return-air/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-return-air/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
	</channel>
</rss>