<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Panel &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/panel/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sat, 13 Oct 2018 09:49:25 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Panel &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>QE90 EWIS Panel</title>
		<link>http://fireandsafetywa.com.au/product/qe90-ewis-panel/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:32 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/qe90-ewis-panel/</guid>
				<description><![CDATA[QE90 panels are specially designed systems made to order panel options include; Amplifiers 10W, 25W, 50W 100W and 200W Warden intercommunication phones and manual Call point interface Strobes and general purpose relays Paging consoles Standard or specially recorded voice messaging Network options including LAN / voice over IP Graphics control panels for networks]]></description>
								<content:encoded><![CDATA[<p>QE90 panels are specially designed systems made to order panel options include;<br />
Amplifiers 10W, 25W, 50W 100W and 200W<br />
Warden intercommunication phones and manual Call point interface<br />
Strobes and general purpose relays<br />
Paging consoles<br />
Standard or specially recorded voice messaging<br />
Network options including LAN / voice over IP<br />
Graphics control panels for networks</p>
]]></content:encoded>
										</item>
		<item>
		<title>4100ES Panel</title>
		<link>http://fireandsafetywa.com.au/product/4100es-panel/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/4100es-panel/</guid>
				<description><![CDATA[The 4100ESi compact is a preassembled single loop fire alarm control panel available off the shelf and comes equipped with he following: 1 x CPU and 4100ESi colour touch screen LCD controller with 2 Gig onboard memory card and Ethernet port 1 x 10 Amp power supply which has 5 amps available for external use [&#8230;]]]></description>
								<content:encoded><![CDATA[<p>The 4100ESi compact is a preassembled single loop fire alarm control panel available off the shelf and comes equipped with he following:<br />
1 x CPU and 4100ESi colour touch screen LCD controller with 2 Gig onboard memory card and Ethernet port<br />
1 x 10 Amp power supply which has 5 amps available for external use<br />
1 x Remote unit interface board (RUI) designed to connect LCD anunciator or remote transponder units (RTUs)<br />
1 x MX 250 device addressable loop<br />
3 x 24V outputs<br />
3 x NACs these are programmable to supply a monitored 24V output<br />
1 x AUX relay output &#8211; 2 Amp rated clean contract programmable relay<br />
3 x Brigade relay outputs<br />
Space for brigade interface (not included please choose option required)<br />
Space to house 1 x 50W tone generator and microphone</p>
]]></content:encoded>
										</item>
		<item>
		<title>Simplex BACpac BACnet Portal with Ethernet Interface</title>
		<link>http://fireandsafetywa.com.au/product/simplex-bacpac-bacnet-portal-with-ethernet-interface/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-bacpac-bacnet-portal-with-ethernet-interface/</guid>
				<description><![CDATA[The 4100-6069 BACpac Ethernet module provides a supplementary communications interface that converts computer terminal information from a compatible Simplex CIE into the building automation protocol of BACnet.]]></description>
								<content:encoded><![CDATA[<p>The 4100-6069 BACpac Ethernet module provides a supplementary communications interface that converts computer terminal information from a compatible Simplex CIE into the building automation protocol of BACnet. With this module, status information from the CIE can be provided to other components of the building automation network with the detail and information format required. This allows the other systems to properly respond to fire alarm system activity in addition to the primary fire alarm response that is under the control of the CIE. </p>
<p>Specifications<br />
&#8211; Input Power                            123mA@24Vdc (c.i.e.)<br />
&#8211; Data Input from CIE              RS232 ASCII<br />
&#8211; Data Output                            BACnet IP<br />
&#8211; Operating Temperature       0°C to +45°C<br />
&#8211; Reletive Humdity                   10% to 93% (non/cond)<br />
&#8211; Dimensions (mm)                2654x51x105 (HWD)</p>
]]></content:encoded>
										</item>
		<item>
		<title>F3200 FIP 8 Zone Fitted 24 Max No Cardframe 6A PSU</title>
		<link>http://fireandsafetywa.com.au/product/f3200-fip-8-zone-fitted-24-max-no-cardframe-6a-psu/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/f3200-fip-8-zone-fitted-24-max-no-cardframe-6a-psu/</guid>
				<description><![CDATA[The F3200 is a self-contained, modular, microprocessor based FIP which performs the functions of the CIE as specified by AS 4428.]]></description>
								<content:encoded><![CDATA[<p>The F3200 is a self-contained, modular, microprocessor based FIP which performs the functions of the CIE as specified by AS 4428. It has a high degree of flexibility and expandability, catering for medium to very large buildings.</p>
<p>A single panel has 8 zones fitted as standard, and can have up to 24 zones. A network system may have up to 64 panels. The F3200 can be fitted with 24 zone LEDs and supports AS 1668 fan controls and gas release.</p>
<p>The F3200 detector circuit electronics caters for a wide range of detectors, it also caters for interfacing to Intrinsically safe circuit barriers/isolators (hazardous areas), long line circuits e.g. from a sub-indicator FIP and tamper-proof circuits. Typically the 15U cabinet has space to accommodate up to 40Ah battery capacity.</p>
]]></content:encoded>
										</item>
		<item>
		<title>F3200 FIP 8 Zones Fitted Small Cabinet 3A MAF/PSU</title>
		<link>http://fireandsafetywa.com.au/product/f3200-fip-8-zones-fitted-small-cabinet-3a-maf-psu/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/f3200-fip-8-zones-fitted-small-cabinet-3a-maf-psu/</guid>
				<description><![CDATA[The 8 zone F3200 will suit small installations requiring a system up to 8 detection circuits.]]></description>
								<content:encoded><![CDATA[<p>The 8 zone F3200 will suit small installations requiring a system up to 8 detection circuits and provides all the features of the existing F3200 Fire Indicator Panel (FIP) range.<br />
This panel is a replacement for the F08 FIP. It is a compact, self-contained<br />
panel which performs the functions of the Control and Indicating Equipment<br />
(CIE), as specified by the Australian Standard AS 4428.1 Fire Detection,<br />
Control and Intercom Systems &#8211; Control and Indicating Equipment.<br />
The 8 zone F3200 offers features including: &#8211;<br />
• AS4428 Firefighter Facility<br />
• LCD Display<br />
• Flexible programmable logic equations<br />
• Event logging to history file<br />
• Networking capabilities &#8211; up to 250 panels (with MX1 as MFIP)<br />
• Eight zones fitted<br />
• Standard 3A Power Supply to power a T-GEN 50<br />
• Battery capacity 2x17Ah<br />
Operation is straightforward with the F3200’s keypad and alphanumeric<br />
LCD. The 40 character, 2 line LCD zone control panel meets the AS 4428.1<br />
“Firefighter Facility” (FF) requirements. “Next” and “Prev” keys allow easy<br />
scrolling through the 99 event alarm buffer, while all current alarms, faults<br />
and isolated zones can be separately displayed.</p>
]]></content:encoded>
										</item>
		<item>
		<title>F3200 AS4428 FIP 8U CAB 3AMP 1U Gas Control Pre-Programmed</title>
		<link>http://fireandsafetywa.com.au/product/f3200-as4428-fip-8u-cab-3amp-1u-gas-control-pre-programmed/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/f3200-as4428-fip-8u-cab-3amp-1u-gas-control-pre-programmed/</guid>
				<description><![CDATA[The F3200 Single Zone (single risk) Gas Control Panel is designed to meet the CIE requirements of AS 4214-2002, “Gaseous Fire Extinguishing Systems”.]]></description>
								<content:encoded><![CDATA[<p>The F3200 Single Zone (single risk) Gas Control Panel is designed to meet the CIE requirements of AS 4214-2002, “Gaseous Fire Extinguishing Systems”. </p>
<p>It includes all circuits and relays normally required for single zone gas control panels. When coupled with the AVI Mk2 warning signs and FP0570/2 Local Gas Control Stations it provides a cost-effective, easily programmed single zone gaseous fire extinguishing system. </p>
<p>FP0876 is an F3200 in an 8U cabinet (FP0784) complete with an ME0442 1 zone, 1U gas control module pre-wired to the 8 zone module and an 8 relay module.</p>
<p>Dimensions<br />
 &#8211; Height     440 mm<br />
 &#8211; Width       550 mm<br />
 &#8211; Depth      211 mm</p>
]]></content:encoded>
										</item>
		<item>
		<title>F3200 AS4428 FIP STD CAB 6AMP 1U Gas Control Pre-Programmed</title>
		<link>http://fireandsafetywa.com.au/product/f3200-as4428-fip-std-cab-6amp-1u-gas-control-pre-programmed/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/f3200-as4428-fip-std-cab-6amp-1u-gas-control-pre-programmed/</guid>
				<description><![CDATA[The F3200 Single Zone (single risk) Gas Control Panel is designed to meet the CIE requirements of AS 4214-2002, “Gaseous Fire Extinguishing Systems”.]]></description>
								<content:encoded><![CDATA[<p>The F3200 Single Zone (single risk) Gas Control Panel is designed to meet the CIE requirements of AS 4214-2002, “Gaseous Fire Extinguishing Systems”. </p>
<p>It includes all circuits and relays normally required for single zone gas control panels. When coupled with the AVI Mk2 warning signs and FP0570/2 Local Gas Control Stations it provides a cost-effective, easily programmed single zone gaseous fire extinguishing system. </p>
<p>FP0877 is based on a 6 Amp power supply F3200 assembled into the standard 15U cabinet (FP0782).  It comes complete with an ME0442 1 zone, 1U gas control module pre-wired to the 8 zone module and an 8 relay module. </p>
<p>Dimensions<br />
 &#8211; Height     750 mm<br />
 &#8211; Width       550 mm<br />
 &#8211; Depth      211 mm</p>
]]></content:encoded>
										</item>
		<item>
		<title>F3200 8 Zone Input Expansion Kit</title>
		<link>http://fireandsafetywa.com.au/product/f3200-8-zone-input-expansion-kit/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/f3200-8-zone-input-expansion-kit/</guid>
				<description><![CDATA[F3200 8 Zone Input Expansion. This module features 8 op to isolated digital inputs.]]></description>
								<content:encoded><![CDATA[<p>F3200 8 Zone Input Expansion Kit</p>
<p>Includes<br />
&#8211; PA0492 8 Zone Module<br />
&#8211; LM0053 FRC,<br />
&#8211; 8 x EOLR (std).<br />
&#8211; (EOL = 2k7 5% 0.4W).</p>
<p>Dimensions<br />
 &#8211; Height     195 mm<br />
 &#8211; Width       125 mm<br />
 &#8211; Depth       12 mm<br />
 &#8211; Weight     220 g</p>
]]></content:encoded>
										</item>
		<item>
		<title>F3200 8 Relay Expansion Kit</title>
		<link>http://fireandsafetywa.com.au/product/f3200-8-relay-expansion-kit/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/f3200-8-relay-expansion-kit/</guid>
				<description><![CDATA[This F3200 relay Board designed for industrial applications requiring isolation between the computer and the external signals it is monitoring and controlling. This module features 8 optoisolated digital inputs and 8 relay outputs.]]></description>
								<content:encoded><![CDATA[<p>This F3200 relay Board designed for industrial applications requiring isolation between the computer and the external signals it is monitoring and controlling. This module features 8 optoisolated digital inputs and 8 relay outputs.</p>
<p>Includes<br />
&#8211; PA0493 8 Relay Module<br />
&#8211; LM0053 FRC<br />
&#8211; 8 x Minijump links (for supervision selection).</p>
<p>Dimensions<br />
 &#8211; Height     195 mm<br />
 &#8211; Width       125 mm<br />
 &#8211; Depth       12 mm<br />
 &#8211; Weight     220 g</p>
]]></content:encoded>
										</item>
		<item>
		<title>F3200 Cardframe Upgrade Kit</title>
		<link>http://fireandsafetywa.com.au/product/f3200-cardframe-upgrade-kit/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/f3200-cardframe-upgrade-kit/</guid>
				<description><![CDATA[A KT0072 Cardframe upgrade kit can be fitted to a 15U F3200 to allow it to take more than three 8 way modules]]></description>
								<content:encoded><![CDATA[<p>A KT0072 Cardframe upgrade kit can be fitted to a 15U F3200 to allow it to take more than three 8 way modules. The KT0072 cardframe can accommodate 8 F3200 modules (for MX4428:- 8 ADR or 6 MPR/MXP/ADR+RRM). </p>
<p>In older versions, the cardframe mounts directly to the rear of the cabinet. In newer versions, the cardframe is fitted to a gear plate that may be removed when the cabinet is mounted to the wall.</p>
]]></content:encoded>