<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MX1 &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/mx1/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:26:37 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>MX1 &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AS4428 Single Loop 15U c/w TGEN AUI / PPU</title>
		<link>http://fireandsafetywa.com.au/product/as4428-single-loop-15u-c-w-tgen-aui-ppu/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:15 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/as4428-single-loop-15u-c-w-tgen-aui-ppu/</guid>
				<description><![CDATA[The VIGILANT MX4428 Single Loop panel is a competitively-priced fire detection and alarm system that targets small to medium sized applications]]></description>
								<content:encoded><![CDATA[<p>The VIGILANT MX4428 Single Loop panel is a competitively-priced fire detection and alarm system that targets small to medium sized applications.  It combines the latest MX DIGITAL analogue addressable technology, pioneered by Tyco, with intelligent fire detection algorithms, powerful control programmability, and 50W tone generator occupancy warning system. As standard, the MX4428 Single Loop panel comes with an MX  Protocol Responder fitted that supports up to 200 MX multi-sensor virtual detectors  (Photoelectric and Heat, CO and Heat, Ionisation-only, Heat-only) and a range of functional bases, addressable callpoints, input modules and output modules. It also includes a prewired brigade interface complete with mounting bracket for Centaur ASE (FP0871) / WA/Cube ASE (FP0872). An optional kit which includes public address, microphone and switch bracket to add PA facility to the pre-installed tone generator is also available. ActivFire Listed afp-1446.</p>
<p>Dimensions<br />
&#8211; Height 750 mm<br />
&#8211; Width 550 mm<br />
&#8211; Depth 211 mm<br />
&#8211; Weight 21kg</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX1 Loop Card Kit</title>
		<link>http://fireandsafetywa.com.au/product/mx1-loop-card-kit/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:15 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx1-loop-card-kit/</guid>
				<description><![CDATA[The MX Digital Loop Card provides MX loop communications for the Simplex 4100ESi fire alarm panel via a single electrically isolated MX Digital loop. It supports up to 250 MX devices - detectors and modules - and provides up to 500mA of loop power.]]></description>
								<content:encoded><![CDATA[<p>The MX Digital Loop Card provides MX loop communications for the Simplex 4100ESi fire alarm panel via a single electrically isolated MX Digital loop. It supports up to 250 MX devices &#8211; detectors and modules &#8211; and provides up to 500mA of loop power.</p>
<p>The 4100-6077AU MX Digital Loop Card (Figure 1) is a flat, 4&#215;10-inch form-factor module that plugs into the Power Distribution Interface (PDI) of the 4100ESi panel.  An earlier version of the card was supplied as 4100-6077LIM, which included an extra bracket on which two LIM800 Loop Isolators were mounted and wired. This version of hardware has been withdrawn, as the 4100-6077AU now includes loop short circuit protection.</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX4428 PSU,240VAC 24V 2.5A Mains Socket Fitted (replaces FP0874)</title>
		<link>http://fireandsafetywa.com.au/product/mx4428-psu240vac-24v-2-5a-mains-socket-fitted-replaces-fp0874/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:15 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx4428-psu240vac-24v-2-5a-mains-socket-fitted-replaces-fp0874/</guid>
				<description><![CDATA[The 5A ME0476 Power Supply is a direct replacement for older 2.5A FP0874/FP0825 supplies]]></description>
								<content:encoded><![CDATA[<p>The 5A ME0476 Power Supply is a direct replacement for older 2.5A FP0874/FP0825 supplies. The ME0476 is used in MX4428 panels (or F4000 upgraded to V3.10+ software).</p>
<p>For AS1603.4 F4000 panels, the 5A FP0882K replaces FP0474. It has the battery test resistors required by AS1603.4. Both supplies feature a 3 pin GPO, replacing the metal mains cover &#038; panel mount mains switch.</p>
<p>Specifications<br />
&#8211; Output                  24Vdc 5A<br />
&#8211; Input                     230Vac 50Hz<br />
&#8211; ActivFire Listed   afp-1341<br />
&#8211; FPANZ Listed      VF/629</p>
]]></content:encoded>
										</item>
		<item>
		<title>MXR Responder in Box</title>
		<link>http://fireandsafetywa.com.au/product/mxr-responder-in-box/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:15 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mxr-responder-in-box/</guid>
				<description><![CDATA[MXR Responder in Box]]></description>
								<content:encoded><![CDATA[<p>The MXP has two major functions:<br />
1. To provide an interface to an MX4428 responder (communications/power)loop, via which data gathered by the MXR may be transferred to the MX4428 Master for display, annunciation, and processing as approiate.<br />
2. To provide an interface to the MX Analogue loop. Data retrieved from the MX devices connected to the analogue loop is processed to determine the ALARM/NORMAL/FAULT status of each device, and this data is passed onto the MX4428 Master via the MX4428 loop interface. </p>
<p>The analogue loop interface also allows outputs to be sent to those devices that support them, to initiate MX device tests,activate relays.</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX Loop Filter Board</title>
		<link>http://fireandsafetywa.com.au/product/mx-loop-filter-board/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:15 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-loop-filter-board/</guid>
				<description><![CDATA[The MXP Loop Filter board is available for fitting to an MXP in order to further improve common-mode interference suppression that may occur as a result of the MXP detector loop not being adequately separated from power wiring, lift motors etc.]]></description>
								<content:encoded><![CDATA[<p>The MXP Loop Filter board is available for fitting to an MXP in order to further improve common-mode interference suppression that may occur as a result of the MXP detector loop not being adequately separated from power wiring, lift motors etc.</p>
<p>Specifications<br />
&#8211; Operating Supply      20 to 40Vdc<br />
&#8211; Dimensions<br />
   &#8211; Height  70 mm<br />
   &#8211; Width   20 mm<br />
   &#8211; Depth   25mm</p>
]]></content:encoded>
										</item>
		<item>
		<title>850EMT Engineer Manager Tool (complete Kit)</title>
		<link>http://fireandsafetywa.com.au/product/850emt-engineer-manager-tool-complete-kit/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:15 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/850emt-engineer-manager-tool-complete-kit/</guid>
				<description><![CDATA[The 850EMT is used to program the address into MX addressable devices. When used with VIGILANT MX1 systems, the 850EMT can also remotely interrogate, address and test 850 Series detectors via a two-way infrared link.]]></description>
								<content:encoded><![CDATA[<p>The 850EMT is used to program the address into MX addressable devices. When used with VIGILANT MX1 systems, the 850EMT can also remotely interrogate, address and test 850 Series detectors via a two-way infrared link. It also displays information and performs tests on devices. </p>
<p>It has a touch screen backlit colour LCD and four ‘softkeys’, ESC, OK, Up and Down. Power for the 850EMT is derived from 6 AA size NiMH rechargeable batteries. It may be run from an unregulated +12Vdc input i.e., car power outlet or 110/230VAC mains adaptor, both of which will recharge the batteries as well.</p>
<p>The 850EMTK consists of the following:<br />
&#8211;  850EMT MX Service Tool<br />
&#8211;  Ancillary programming lead &#038; spare pins<br />
&#8211;  6 x rechargeable AA size NiMH batteries<br />
&#8211;  240VAC Adaptor plus Lead<br />
&#8211;  12Vdc car adaptor<br />
&#8211;  Hard Carry Case</p>
<p>Specifications<br />
&#8211; Batteries                          6xAA NiMH<br />
&#8211; Batt. Operating Time     up to 15 hours<br />
&#8211; Ambient Temp                0 to +50°C<br />
&#8211; Relative Humidity          10% to 90% (n/cond)<br />
&#8211; Dimensions*<br />
  &#8211; Height   50 mm<br />
  &#8211; Width     210 mm<br />
  &#8211; Depth    125mm<br />
&#8211; Weight*                            600g incl. batteries</p>
<p>* For 850EMT unit only</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX4428 ADR-M 4mA Detector Current 1901-116</title>
		<link>http://fireandsafetywa.com.au/product/mx4428-adr-m-4ma-detector-current-1901-116/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:15 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx4428-adr-m-4ma-detector-current-1901-116/</guid>
				<description><![CDATA[The FP0755 version of ADR supports the 15V MCP, the 614 series of detectors and all the other detectors from earlier versions of ADR, along with some new programmable circuit types.]]></description>
								<content:encoded><![CDATA[<p>The FP0755 version of ADR supports the 15V MCP, the 614 series of detectors and all the other detectors from earlier versions of ADR, along with some new programmable circuit types. The ADR-M and its new version software replaces the existing ADRs for standard production and can be purchased under part numbers listed. The existing ADR part numbers will still be available in low quantities for service replacements and upgrades. Please note that the new ADR-M software MUST NOT be installed in any existing 2.5mA or 4mA ADR PCBs as it will not work properly</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX1 Single Loop 8U Panel 3U Blank (fit brigade kit separately)</title>
		<link>http://fireandsafetywa.com.au/product/mx1-single-loop-8u-panel-3u-blank-fit-brigade-kit-separately/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:15 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx1-single-loop-8u-panel-3u-blank-fit-brigade-kit-separately/</guid>
				<description><![CDATA[The simple and cost effective solution for small to medium installations 

The VIGILANT MX1 is an innovative, networkable, multi-loop analogue addressable fire indicator panel incorporating the latest technology and complying with the ISO-based AS 7240.2-2004 standard and including an integrated Fire Brigade Panel to AS 4428.3-2004.]]></description>
								<content:encoded><![CDATA[<p>The simple and cost effective solution for small to medium installations </p>
<p>The VIGILANT MX1 is an innovative, networkable, multi-loop analogue addressable fire indicator panel incorporating the latest technology and complying with the ISO-based AS 7240.2-2004 standard and including an integrated Fire Brigade Panel to AS 4428.3-2004.</p>
<p>Its support for Tyco MX TECHNOLOGY, fuzzy-logic detection algorithms and powerful control functions make it suitable for a wide range of fire detection applications including those in hazardous areas. </p>
<p>Our VIGILANT® MX1 fire panels can be used to provide cost effective solutions for small to medium fire detection systems, whilst also providing many of the features and functions required for very large industrial and multi-building sites.</p>
<p>Basic System Comprises:</p>
<p>&#8211; Rapid response to fire conditions, yet a low rate of nuisance alarms achieved through<br />
   &#8211; MX SMARTSENSE and FASTLOGIC detection algorithms<br />
   &#8211; MX TECHNOLOGY® heat enhanced smoke detection algorithms<br />
   &#8211; MX TECHNOLOGY® carbon monoxide (CO) fire detection<br />
&#8211; Single MX DIGITAL loop supporting up to 250 MX devices<br />
&#8211; Up to 7 optional MX Loop cards expand capacity to 2000 MX devices<br />
&#8211; Analogue addressable triple sensor detector &#8211; photoelectric smoke, heat and CO<br />
&#8211; Analogue addressable; high sensitivity smoke detector (VESDA), flame detectors and Ex rated detectors and modules<br />
&#8211; Loop powered sounder bases and beacon<br />
&#8211; Alarm Investigation Facility (AIF)<br />
&#8211; Alarm Acknowledge Facility (AAF) to AS 7240.2<br />
&#8211; Residential mode (Smoke local alarm, Heat general alarm)<br />
&#8211; Plain English alarm messages on 4-line, 40 character LCD<br />
&#8211; Compact zone LED display modules for up to 192 zones<br />
&#8211; Event logging to internal non-volatile history file<br />
&#8211; Event printer port and repeater panel port<br />
&#8211; High level VIGILANT® QE90 EWIS interface<br />
&#8211; Dual databases for reduced downtime and increased security<br />
&#8211; Windows®- based programming tool<br />
&#8211; Day/ night modes for alarm sensitivity adjustment and output logic functions<br />
 -Internal 5A p.s.e. / battery charger<br />
&#8211; Internal mounting for optional T-GEN 50 or Mini-Gen Occupant Warning Systems</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX1 Single Loop 15U Panel 3U Blank</title>
		<link>http://fireandsafetywa.com.au/product/mx1-single-loop-15u-panel-3u-blank/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:15 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx1-single-loop-15u-panel-3u-blank/</guid>
				<description><![CDATA[The Vigilant MX1 is an innovative single loop analogue addressable fire indicator panel incorporating the latest technology.  It complies with AS 4428.3.2004, AS 7240.4.2004.  Its support for Tyco MX technology, fuzzy logic detection algorithms and powerful control functions make it suitable for a wide range of fire protection applications for small to medium size systems and those in hazardous areas.]]></description>
								<content:encoded><![CDATA[<p>The Vigilant MX1 is an innovative single loop analogue addressable fire indicator panel incorporating the latest technology.  It complies with AS 4428.3.2004, AS 7240.4.2004.  Its support for Tyco MX technology, fuzzy logic detection algorithms and powerful control functions make it suitable for a wide range of fire protection applications for small to medium size systems and those in hazardous areas.</p>
<p>MX1 supports the comprehensive range of MX multi-sensor virtual detectors: (Photoelectric/CO/Heat, Photoelectric only, CO and Heat, Ionization only, Heat only) and a range of functional bases, analogue addressable call points, input and output modules. Smoke/CO and temperature readings from the multi sensor detectors can be combined in various ways to achieve optimum detection and nuisance alarm rejection for each location</p>
]]></content:encoded>