<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Intrinsically Safe &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/intrinsically-safe/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:30:13 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Intrinsically Safe &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MX 801CHEx Intrinsically Safe (I.S) Carbon Monoxide &#038; Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801chex-intrinsically-safe-i-s-carbon-monoxide-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801chex-intrinsically-safe-i-s-carbon-monoxide-heat-detector/</guid>
				<description><![CDATA[The 801CHEx Intrinsically Safe Carbon Monoxide plus Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base.]]></description>
								<content:encoded><![CDATA[<p>The 801CHEx Intrinsically Safe Carbon Monoxide plus Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the carbon monoxide and heat elements of the detector. Software within the controller is used to interpret the returned Carbon Monoxide and heat values to raise an alarm or other appropriate response according to the  programmed configuration.</p>
<p>The mode of detector may be:<br />
&#8211; Heat only detector (A1R or A2S) (sensitivity: High, Normal or Low)<br />
&#8211; Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)<br />
&#8211; Compensated Carbon Monoxide detector (sensitivity: High or Normal ) combined with heat (A1R)</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus.</p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                   18 to 24Vdc<br />
&#8211; Queiscent Current                  400µA (max.)<br />
&#8211; Alarm Current                          3.5mA (max.)<br />
&#8211; Operating Tempearture         0°C to +50°C<br />
&#8211; Relative Humidity                   15% to 90% (non-cond.)<br />
&#8211; FPANZ Listed                          VF/352<br />
&#8211; IECEX Certificate                    IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX 801HEx Intrinsically Safe (I.S) Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801hex-intrinsically-safe-i-s-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801hex-intrinsically-safe-i-s-heat-detector/</guid>
				<description><![CDATA[The 801HEx Intrinsically Safe Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base]]></description>
								<content:encoded><![CDATA[<p>The 801HEx Intrinsically Safe Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the heat element of the detector. Software within the controller is used to interpret the returned heat values to raise an alarm or other appropriate response according to the programmed configuration.</p>
<p>The mode of detector may be:<br />
&#8211; EN54-5 A1R, rate-of-rise normal ambient<br />
&#8211; EN54-5 A2S, fixed 60°C<br />
&#8211; EN54-5 CR, rate-of-rise high ambient</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus.</p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                     18 to 24Vdc<br />
&#8211; Queiscent Current                    400µA (max.)<br />
&#8211; Alarm Current                            3.5mA (max.)<br />
&#8211; Operating Tempearture           -25°C to +70°C<br />
&#8211; Relative Humidity                      10% to 95% (non-cond.)<br />
&#8211; FPANZ Listed                             VF/216<br />
&#8211; IECEX Certificate                       IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX CP840Ex Intrinsically Safe(I.S) Manual Callpoint</title>
		<link>http://fireandsafetywa.com.au/product/mx-cp840ex-intrinsically-safei-s-manual-callpoint/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-cp840ex-intrinsically-safei-s-manual-callpoint/</guid>
				<description><![CDATA[The CP840Ex Intrinsically Safe Waterproof Break Glass Manual Call Point is designed to monitor and signal the condition of the switch contact associated with the call point. The callpoint is designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus.]]></description>
								<content:encoded><![CDATA[<p>The CP840Ex Intrinsically Safe Waterproof Break Glass Manual Call Point is designed to monitor and signal the condition of the switch contact associated with the call point. The callpoint is designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus. </p>
<p>It is certified:<br />
&#8211; IECEX Certificate                      BAS 07.0063X<br />
&#8211; ATEX Classification                 Ex II 1 G<br />
&#8211; ATEX Certificate                        BAS01ATEX1394X<br />
&#8211; Cenelec Classification           EEx ia IIC T5</p>
<p>The CP840Ex does not comply with NZS4512.</p>
<p>Specifications<br />
&#8211; Operating Voltage                  18 to 24Vdc<br />
&#8211; Queiscent Current                  300µA (max.)<br />
&#8211; Alarm Current                          5mA (max.)<br />
&#8211; Operating Tempearture         -25°C to +70°C<br />
&#8211; Relative Humidity                   10% to 95% (non-cond.)<br />
&#8211; Dimensions (HWD)               124 x 124 x 59 mm<br />
&#8211; Ingress Protection                  IP67<br />
&#8211; ATEX Certificate                      BAS01ATEX1394X<br />
&#8211; IECEX Certificate                    BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>601FEX Conventional Flame Detector Intrinsically Safe</title>
		<link>http://fireandsafetywa.com.au/product/601fex-conventional-flame-detector-intrinsically-safe/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/601fex-conventional-flame-detector-intrinsically-safe/</guid>
				<description><![CDATA[The 601FEx point type flame detectors are part of the 600 series of non-addressable detectors. The 601FEx is a full featured flame detector for indoor use.]]></description>
								<content:encoded><![CDATA[<p>The 601FEx point type flame detectors are part of the 600 series of non-addressable detectors. The 601FEx is a full featured flame detector for indoor use. It has a high degree of false alarm immunity. The 601FEx and it is designed for connection to a conventional zone of point type fire detectors that may include any mix of detection technologies.  The 601FEx is an intrinsically safe version intended for use in hazardous atmospheres and must be connected via a suitable isolator or shunt diode safety barrier in a certified Intrinsically Safe system.</p>
<p>Specifications<br />
&#8211; Operating Voltage                16 to 28Vdc<br />
&#8211; Operating Current                300 µA (max.)<br />
&#8211; Alarm Current                       30mA @ 15Vdc<br />
&#8211; Operating Temp                   -20°C to +70°C<br />
&#8211; Relative Humidity                 90% (non-cond.)*<br />
&#8211; Dimensions                          108 dia x 22 H mm<br />
&#8211; Weight                                    110g<br />
&#8211; Range                                     0.1m2 n-heptane @ 20m<br />
                                                   0.4m2 n-heptane @ 50m<br />
&#8211; Field of View                          100°<br />
&#8211; ATEX Certificate                    BASEEFA03ATEX0422X<br />
&#8211; ATEX Code                            Ex II 1 G<br />
&#8211; Cenelec Code                      EEx ia IIC T5<br />
&#8211; IECEX Certificate                  BAS 07.0075X</p>
<p>*  90% RH continuous; 99% RH (non-cond.) intermittent operation</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX 801PHEx Intrinsically Safe (I.S) Photoelectric &#038; Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801phex-intrinsically-safe-i-s-photoelectric-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801phex-intrinsically-safe-i-s-photoelectric-heat-detector/</guid>
				<description><![CDATA[The 801PHEx Intrinsically Safe Optical Smoke &#038; Heat Detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the optical smoke and heat elements of the detector.]]></description>
								<content:encoded><![CDATA[<p>The 801PHEx Intrinsically Safe Optical Smoke &#038; Heat Detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the optical smoke and heat elements of the detector. Software within the controller interprets the returned optical and heat values to raise an alarm or other appropriate response according to the type of programmed configuration. </p>
<p>The mode of detector may be:<br />
&#8211; Optical smoke only detector (High/ Normal/Low)<br />
&#8211; HPO smoke detector (sensitivity High, Normal or Low)<br />
&#8211; Heat only rate-of-rise (A1R) detector (no sensitivity selection)<br />
&#8211; Heat fixed temperature 60°C (A2S) (no sensitivity selection)<br />
&#8211; Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60°C (A2S)<br />
&#8211; HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60°C (A2S)</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus. </p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                 18 to 24Vdc<br />
&#8211; Queiscent Current                 400µA (max.)<br />
&#8211; Alarm Current                         3.5mA (max.)<br />
&#8211; Operating Tempearture        -25°C to +70°C<br />
&#8211; Relative Humidity                   10% to 95% (non-cond.)<br />
&#8211; FPANZ Listed                          VF/351<br />
&#8211; IECEX Certificate                    IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MR601TEX High Performance Optical Intrinsically Safe</title>
		<link>http://fireandsafetywa.com.au/product/mr601tex-high-performance-optical-intrinsically-safe/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mr601tex-high-performance-optical-intrinsically-safe/</guid>
				<description><![CDATA[The MR601TEX has been developed to overcome  the slower response of the optical detectors to hot burning fires, by increasing the sensitivity of the optical detector when it is associated with a rapid change in temperature.]]></description>
								<content:encoded><![CDATA[<p>The MR601TEX has been developed to overcome  the slower response of the optical detectors to hot burning fires, by increasing the sensitivity of the optical detector when it is associated with a rapid change in temperature. In this way it is intended to become a detector which can cover some of the risks currently covered by ion chamber detectors. Smoke detectors will not detect burning alcohol or other clean-burning liquids which do not generate smoke particles. </p>
<p>Specifications<br />
&#8211; Operating Voltage              16 to 28Vdc<br />
&#8211; Operating Current              110 µA (max.)<br />
&#8211; Alarm Current                      30mA @ 16Vdc<br />
&#8211; Operating Temp                  -20°C to +70°C<br />
&#8211; Relative Humidity                95% (non-cond.)<br />
&#8211; Dimensions                        109 dia x 43 H mm<br />
&#8211; Weight                                  128g<br />
&#8211; ATEX Certificate                  BAS01ATEX11134X.<br />
&#8211; IECEX Certificate                BAS 07.0056X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MD611EX Fixed Temperature Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/md611ex-fixed-temperature-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/md611ex-fixed-temperature-heat-detector/</guid>
				<description><![CDATA[Where environmental conditions rule out the use of smoke detectors, MD601Ex/MD611Ex heat detectors may provide an acceptable, though less sensitive, alternative.]]></description>
								<content:encoded><![CDATA[<p>Where environmental conditions rule out the use of smoke detectors, MD601Ex/MD611Ex heat detectors may provide an acceptable, though less sensitive, alternative. For general use (particularly where the ambient temperature may be low) a ‘Rate-of-Rise’  (ROR) heat sensor is preferred. These detectors react to abnormally high rates of change of temperature and provide the fastest response over a wide range of ambient temperatures. A fixed temperature limit is incorporated in these detectors. In kitchens and  boiler rooms etc, sudden, large changes in temperature are considered ‘normal’. Fixed temp. [static] detectors should be used in this case. </p>
<p>Specifications<br />
&#8211; Operating Voltage              16 to 28Vdc<br />
&#8211; Operating Current              100µA (max.)<br />
&#8211; Alarm Current                      5 to 80mA<br />
&#8211; Operating Temp                 -20°C to +70°C<br />
&#8211; Relative Humidity                95% (non-cond.)<br />
&#8211; Dimensions                        109 dia x 43 H mm<br />
&#8211; Weight                                  116g<br />
&#8211; ATEX Certificate                  BAS01ATEX1134X<br />
&#8211; IECEX Certificate                BAS 07.0056X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MD601EX Rate of Rise Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/md601ex-rate-of-rise-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/md601ex-rate-of-rise-heat-detector/</guid>
				<description><![CDATA[Where environmental conditions rule out the use of smoke detectors, MD601Ex/MD611Ex heat detectors may provide an acceptable, though less sensitive, alternative.]]></description>
								<content:encoded><![CDATA[<p>Where environmental conditions rule out the use of smoke detectors, MD601Ex/MD611Ex heat detectors may provide an acceptable, though less sensitive, alternative. For general use (particularly where the ambient temperature may be low) a ‘Rate-of-Rise’  (ROR) heat sensor is preferred. These detectors react to abnormally high rates of change of temperature and provide the fastest response over a wide range of ambient temperatures. A fixed temperature limit is incorporated in these detectors. In kitchens and  boiler rooms etc, sudden, large changes in temperature are considered ‘normal’. Fixed temp. [static] detectors should be used in this case. </p>
<p>Specifications<br />
&#8211; Operating Voltage              16 to 28Vdc<br />
&#8211; Operating Current              100µA (max.)<br />
&#8211; Alarm Current                      5 to 80mA<br />
&#8211; Operating Temp                 -20°C to +70°C<br />
&#8211; Relative Humidity                95% (non-cond.)<br />
&#8211; Dimensions                        109 dia x 43 H mm<br />
&#8211; Weight                                  116g<br />
&#8211; ATEX Certificate                  BAS01ATEX1134X<br />
&#8211; IECEX Certificate                BAS 07.0056X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MDU601EX Enhanced Heat and Carbon Monoxide Detector</title>
		<link>http://fireandsafetywa.com.au/product/mdu601ex-enhanced-heat-and-carbon-monoxide-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mdu601ex-enhanced-heat-and-carbon-monoxide-detector/</guid>
				<description><![CDATA[The MDU601EX detector combines the features of both the MU601EX detector and the MD601EX detector to provide a combined CO and Rate of Rise Heat Detector where the sensitivity of the CO detector is enhanced in response to a fast rate of change of temperature.]]></description>
								<content:encoded><![CDATA[<p>The MDU601EX detector combines the features of both the MU601EX detector and the MD601EX detector to provide a combined CO and Rate of Rise Heat Detector where the sensitivity of the CO detector is enhanced in response to a fast rate of change of temperature. </p>
<p>Specifications<br />
&#8211; Operating Voltage        16 to 28Vdc<br />
&#8211; Operating Current         70 µA (max.)<br />
&#8211; Alarm Current                30mA @ 15Vdc<br />
&#8211; Operating Temp            -20°C to +70°C<br />
&#8211; Relative Humidity          90% (non-cond.)<br />
&#8211; Dimensions                   109 dia x 43 H mm<br />
&#8211; Weight                             126g<br />
&#8211; ATEX Certificate             BAS01ATEX1134X<br />
&#8211; IECEX Certificate           BAS 07.0056X</p>