<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IDNET &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/idnet/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Wed, 26 Mar 2025 08:44:47 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.21</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>IDNET &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>IDNet Relay IAM with Unsupervised Input  (Uses RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/idnet-relay-iam-with-unsupervised-input-uses-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/idnet-relay-iam-with-unsupervised-input-uses-raco232-lid/</guid>
				<description><![CDATA[The 4090-9119 allows a 4100ES IDNet communication channel to monitor an unsupervised input contact with one point and control an output relay with the other point, yet occupy a single address]]></description>
								<content:encoded><![CDATA[<p>The 4090-9119 allows a 4100ES IDNet communication channel to monitor an unsupervised input contact with one point and control an output relay with the other point, yet occupy a single address. The input circuit and relay operation are controlled independently and may be disabled separately. Module power is supplied from the IDNet communications channel eliminating the need for separate power wiring. The address is set by DIP switch under the re-sealable label.</p>
<p>Specifications<br />
&#8211; Comms Power                           24 to 40Vdc w/data*<br />
&#8211; Relay Contact Ratings SPDT<br />
    Non power limited                    0.5A @120VAC**<br />
                                                         0.25A@120VAC***<br />
     Power limited                           2A@30Vdc**<br />
                                                         1A@30Vdc***<br />
&#8211; Input                                              N/O, dry contacts<br />
&#8211; Dimensions (HWD)                   105 x 105 x 35 mm<br />
&#8211; Ambient Temperature               0 to +49°C<br />
&#8211; Relative Humidity                       10% to 95% (n/c)</p>
<p>*      IDNet communications with data<br />
**    Resistive Load<br />
***   Inductive Load<br />
Note: Loop powered 2 wire device</p>
]]></content:encoded>
										</item>
		<item>
		<title>IDNet 6 Point I/O Module (4 I/Ps + 2 relay O/Ps) (Uses RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/idnet-6-point-i-o-module-4-i-ps-2-relay-o-ps-uses-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/idnet-6-point-i-o-module-4-i-ps-2-relay-o-ps-uses-raco232-lid/</guid>
				<description><![CDATA[The 4090-9120 allows 4100ES IDNet communication channel to monitor four T-sense input circuits and control two output relays from a single module requiring a single address.]]></description>
								<content:encoded><![CDATA[<p>The 4090-9120 allows 4100ES IDNet communication channel to monitor four T-sense input circuits and control two output relays from a single module requiring a single address. Power is supplied by a separate 24Vdc connection to a listed fire alarm power  supply. The input circuits and output relay operation are controlled independently and may be disabled separately. Point association is determined at the 4100ES host panel. At the 4100ES, the device address is designated as a single hardware location. Each of the four input circuits monitors for continuity to an end-of-line resistor and can differentiate between a short circuit contact closure and a current limited contact closure. Two input supervision resistors are required per T-sense input.</p>
<p>Specifications<br />
&#8211; Comms Power                       24 to 40Vdc w/data*<br />
&#8211; Operating Voltage                  18 to 32Vdc<br />
&#8211; Operating Current                  30mA@24Vdc<br />
&#8211; Relay Contact Ratings SPDT<br />
   Non-power limited                 0.5A @120VA**<br />
                                                      0.25A@120VAC***<br />
&#8211; Power limited                           2A@30Vdc**<br />
                                                      1A@30Vdc***<br />
&#8211; Supervision Resistor              6k8 Ohm 0.5W<br />
&#8211; Current Limited Operation     1k8/4k7 0.5W<br />
&#8211; Input                                            N/O, dry contacts<br />
&#8211; LED Output                                24Vdc (external PSU)<br />
&#8211; Dimensions (HWD)                 105 x 105 x 35 mm<br />
&#8211; Ambient Temperature             0 to +49°C<br />
&#8211; Relative Humidity                     10% to 90% (n/c)</p>
<p>*     IDNet communications with data<br />
**   Resistive Load<br />
***  Inductive Load<br />
Note: 4 wire device; requires separate 24Vdc and IDNet communication loop</p>
]]></content:encoded>
										</item>
		<item>
		<title>Addressable MCP Mounting Box</title>
		<link>http://fireandsafetywa.com.au/product/addressable-mcp-mounting-box/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/addressable-mcp-mounting-box/</guid>
				<description><![CDATA[Red surface mounting back box (for indoor callpoints) with terminals fitted.]]></description>
								<content:encoded><![CDATA[<p>Red surface mounting back box (for indoor callpoints) with terminals fitted.</p>
]]></content:encoded>
										</item>
		<item>
		<title>IDNet Monitor ZAM (Use RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/idnet-monitor-zam-use-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/idnet-monitor-zam-use-raco232-lid/</guid>
				<description><![CDATA[The 4090-9101 Zone Adaptor Module Monitor ZAM allows a 2-wire circuit of collective smoke or heat detectors to be interfaced on to the IDNet loop]]></description>
								<content:encoded><![CDATA[<p>The 4090-9101 Zone Adaptor Module Monitor ZAM allows a 2-wire circuit of collective smoke or heat detectors to be interfaced on to the IDNet loop. Up to 20 collective heat and smoke detectors can be monitored by a 4090-9101 Monitor ZAM. The address is set by DIP switch under the resealable label. Note the 4090-9101 requires a separate 24Vdc power supply to power the collective circuit.</p>
<p>Specifications<br />
&#8211; Comms Power                  24 to 40Vdc w/data*<br />
&#8211; Operating Voltage            18.9 to 32Vdc<br />
&#8211; ZAM Current @ 24Vd **<br />
    &#8211; Quiescent                       16mA max.<br />
    &#8211; Alarm                               72mA max.<br />
&#8211; Supervision Resistor       3k3 Ohm 1W<br />
&#8211; Dimensions (HWD)          105 x 105 x 35mm<br />
&#8211; Ambient Temperature       0 to +49°C<br />
&#8211; Relative Humidity               10% to 93% (n/c)</p>
<p>*     IDNet Communications with data<br />
**   Actual current value is determined by total device requirements</p>
]]></content:encoded>
										</item>
		<item>
		<title>IDNet Relay Output IAM  (RIAM) (Uses RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/idnet-relay-output-iam-riam-uses-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/idnet-relay-output-iam-riam-uses-raco232-lid/</guid>
				<description><![CDATA[The 4090-9002 Relay IAM allows the CIE to control a remotely located Form “C” Relay contact using IDNet addressable communications for both data and module power]]></description>
								<content:encoded><![CDATA[<p>The 4090-9002 Relay IAM allows the CIE to control a remotely located Form “C” Relay contact using IDNet addressable communications for both data and module power. Typical applications are for switching local power for control functions such as magnetic door holders, or control of HVAC components, pressurisation fans, dampers, etc.. Relay contact status is also communicated to the CIE. The address is set by DIP switch under the resealable label.</p>
<p>Specifications<br />
&#8211; Comms Power                          24 to 40Vdc w/data*<br />
&#8211; Relay Contact Ratings SPDT<br />
                                                        0.5A @120VAC**<br />
                                                        2A@24Vdc***<br />
                                                        1A@24Vdc***<br />
&#8211; Current Limited Op                   1k8/4k7 0.5W<br />
&#8211; Dimensions (HWD)                  105 x 105 x 35mm<br />
&#8211; Ambient Temperature               0 to +49°C<br />
&#8211; Relative Humidity                       10% to 93% (n/c)</p>
<p>*      IDNet communications with data<br />
**    Transient suppressed load<br />
***   Inductive load<br />
Note: Loop powered 2 wire device</p>
]]></content:encoded>
										</item>
		<item>
		<title>IDnet Addressable Signal IAM (Uses RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/idnet-addressable-signal-iam-uses-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/idnet-addressable-signal-iam-uses-raco232-lid/</guid>
				<description><![CDATA[This IDNet addressable device provides a supervised,addressable interface to conventional warning devices such as sounders or strobes.]]></description>
								<content:encoded><![CDATA[<p>This IDNet addressable device provides a supervised,addressable interface to conventional warning devices such as sounders or strobes. The Signal IAM requires a supervised power supply or compatible signal input for powering the externally connected<br />
loads.</p>
<p>&#8211; Provides a single switched branch with supervision<br />
&#8211; Contact is fused at 0.5A for 30V DC or 70V AC.<br />
   Uses standard 20 x 5mm cartridge fuse<br />
&#8211; EOLR is 10k.<br />
&#8211; DC loads must be diode isolated<br />
&#8211; Supervision cannot be disabled<br />
&#8211; The supply side and the internal fuse are not supervised by the Signal IAM<br />
&#8211; Signal IAM is not suitable for switching 100V audio signals</p>
<p>Specifications<br />
&#8211; Operating Voltage            24Vdc, Loop Supplied<br />
&#8211; Operating Current            170 mA<br />
&#8211; Operating Temp                0 to 49°C<br />
&#8211; Relative Humidity             10% to 93% (non-cond)<br />
&#8211; Dimensions                      102 x 105 x 32 mm</p>
]]></content:encoded>
										</item>
		<item>
		<title>IDnet Encapsulated IAM  (Uses RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/idnet-encapsulated-iam-uses-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/idnet-encapsulated-iam-uses-raco232-lid/</guid>
				<description><![CDATA[This IDNet addressable device is an encapsulated version of 4090-9001. It has both power and communications supplied by a two-wire IDNet circuit.]]></description>
								<content:encoded><![CDATA[<p>This IDNet addressable device is an encapsulated version of 4090-9001. It has both power and communications supplied by a two-wire IDNet circuit. It provides location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor.</p>
<p>Specifications<br />
&#8211; Operating Voltage               24 to 40Vdc*<br />
&#8211; Operating Current               170 mA<br />
&#8211; End-of-Line Resistor          6k8 Ohm 0.5W<br />
&#8211; Operating Temp                  0 to 49°C<br />
&#8211; Relative Humidity                10% to 93% (non-cond)<br />
&#8211; Dimensions                          40 x 40 x 14 mm</p>
<p>*  IDNet, 1 address per unit</p>
]]></content:encoded>
										</item>
		<item>
		<title>Addressable IDNet Isolator (Uses RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/addressable-idnet-isolator-uses-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/addressable-idnet-isolator-uses-raco232-lid/</guid>
				<description><![CDATA[The 4090-9116 Isolator provides IDNet communications isolation, improving installation convenience and system integrity.]]></description>
								<content:encoded><![CDATA[<p>The 4090-9116 Isolator provides IDNet communications isolation, improving installation convenience and system integrity. Isolation is automatically activated when an output short circuit is detected and the condition is reported to the CIE. Circuit isolation can also be selected manually from the 4100ES CIE to enable partial loop testing. If the output wiring is acceptable, the isolator will connect  the rest of the circuit. If the output wiring is shorted, the isolator remains isolated. The address is set by DIP switch under the re-sealable label.</p>
<p>Specifications<br />
&#8211; Comms Power                 24 to 40Vdc w/data*<br />
&#8211; Dimensions (HWD)        105 x 105 x 35 mm<br />
&#8211; Ambient Temperature     0 to +49°C<br />
-Relative Humidity              10% to 90% (n/c)</p>
<p>*   IDNet communications with data</p>
]]></content:encoded>
										</item>
		<item>
		<title>IDNet Relay IAM with T-Sense Input (Uses RACO232 &#038; Lid)</title>
		<link>http://fireandsafetywa.com.au/product/idnet-relay-iam-with-t-sense-input-uses-raco232-lid/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/idnet-relay-iam-with-t-sense-input-uses-raco232-lid/</guid>
				<description><![CDATA[The 4090-9118 Relay IAM with T-Sense allows a 4100ES IDNet communication channel to monitor two input contact closures with one point and control an output relay with the other point, yet occupy a single loop address.]]></description>
								<content:encoded><![CDATA[<p>The 4090-9118 Relay IAM with T-Sense allows a 4100ES IDNet communication channel to monitor two input contact closures with one point and control an output relay with the other point, yet occupy a single loop address. Power is supplied from the IDNet communications channel, eliminating the need for separate power wiring. The input circuit and relay operation are controlled independently and may be disabled separately. Applications include water flow and tamper switch monitoring and control and damper position monitoring and control</p>
<p>Specifications<br />
&#8211; Comms Power                          24 to 40Vdc w/data *<br />
&#8211; Relay Contact Ratings SPDT<br />
                                                        0.5A @120VAC**<br />
                                                        0.25A@120VAC***<br />
                                                        2A@30Vdc**<br />
                                                        1A@30Vdc***<br />
&#8211; Input                                             N/O, dry contacts<br />
&#8211; Current Limited Operation      1k8/4k7 0.5W<br />
&#8211; Dimensions (HWD)                  105 x 105 x 35 mm<br />
&#8211; Ambient Temperature              0 to +49°C<br />
&#8211; Relative Humidity                      10% to 90% (n/c)</p>
<p>*      IDNet communications with data<br />
**    Resistive Load<br />
***   Inductive Load<br />
Note: Loop powered 2 wire device</p>
]]></content:encoded>
										</item>
	</channel>
</rss>
