<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Heat &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/heat/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:36:22 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Heat &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Sampling Point Heat Activated</title>
		<link>http://fireandsafetywa.com.au/product/sampling-point-heat-activated/</link>
				<pubDate>Sun, 07 Oct 2018 13:36:05 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/sampling-point-heat-activated/</guid>
				<description><![CDATA[This product is a Heat Activated Sampling Point.]]></description>
								<content:encoded><![CDATA[<p>Sample points are ideal for use when there is a false ceiling and the pipwork is in the concealed space.  When there are areas in which smoke is present from time to time being small kitchenettes or breakout areas, Heat Activated Sampling Points (HASP) are ideal to apply.<br />
By utilising a HASP, no air is drawn through the sampling hole as there is a small amount of special sealent.  This sealant has been designed to melt at approximately 60° Celsius.  Eache HASP is connected back to the main sampling pipe via capilary tubes and fittings as per a normal sample point.<br />
This product is a Heat Activated Sampling Point.</p>
]]></content:encoded>
										</item>
		<item>
		<title>Heat Sensor &#8211; TrueAlarm</title>
		<link>http://fireandsafetywa.com.au/product/heat-sensor-truealarm/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/heat-sensor-truealarm/</guid>
				<description><![CDATA[TrueAlarm heat detectors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing]]></description>
								<content:encoded><![CDATA[<p>TrueAlarm heat detectors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the detector accurately and quickly measures the local temperature for analysis at the c.i.e. Rate-ofrise temperature detection is selectable for either 8.3°C or 11.1°C per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 57.2°C or 68°C. In a slow developing fire, the  temperature may not increase rapidly enough to operate the rate-of-rise  feature, however an alarm will be initiated when the temperature reaches its rated fixed temp. setting.<br />
Specifications<br />
&#8211; Operating Voltage                              24 to 40Vdc*<br />
&#8211; Quiescent Current (max)                  400µA<br />
&#8211; Alarm Current (max)                          10mA<br />
&#8211; External Output Drive (max)             5mA<br />
&#8211; Relative Humidity                              10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                       0 to +50°C<br />
&#8211; ActivFire Listed                                   afp-1202</p>
<p>* MAPNET II or IDNet auto select</p>
]]></content:encoded>
										</item>
		<item>
		<title>Photo / Heat Multi Sensor &#8211; TrueAlarm</title>
		<link>http://fireandsafetywa.com.au/product/photo-heat-multi-sensor-truealarm/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/photo-heat-multi-sensor-truealarm/</guid>
				<description><![CDATA[TrueAlarm multi-sensor 4098-9754EA combines the TrueAlarm photoelectric smoke sensor with a fast-acting and accurate TrueAlarm thermal sensor to provide both features in a single sensor/base assembly.]]></description>
								<content:encoded><![CDATA[<p>TrueAlarm multi-sensor 4098-9754EA combines the TrueAlarm photoelectric smoke sensor with a fast-acting and accurate TrueAlarm thermal sensor to provide both features in a single sensor/base assembly. Analog information from each sensor is digitally communicated to the control panel where it is analysed. Photoelectric sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor’s present value against its average value. Thermal<br />
data is processed to look for absolute or rate-of-rise temperature as desired. Monitoring each photoelectric sensor’s average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging. The result is a significant reduction in false or nuisance alarms caused by shifts in sensitivity</p>
<p>Specifications<br />
4098-9754E<br />
&#8211; Operating Voltage (MAPNET II)          24 to 40Vdc<br />
&#8211; Operating Current (MAPNET II)          500µA (max)<br />
&#8211; Relative Humidity                                  10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                          0 to +50°C<br />
&#8211; Sensitivity (at c.i.e.)                               4 and 5%Obs/m<br />
with 4098-9795E<br />
&#8211; Alarm Current (sounder on)                17mA @ 24Vdc<br />
&#8211; Sounder Power (external)                    18 to 32Vdc<br />
&#8211; Sound Pressure Level                          88dBA @ 3m<br />
 -ActivFire Listed (MAPNET)                    afp-1361</p>
<p>*MAPNET II or IDNet auto select w/data</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX 801PHEx Intrinsically Safe (I.S) Photoelectric &#038; Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801phex-intrinsically-safe-i-s-photoelectric-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801phex-intrinsically-safe-i-s-photoelectric-heat-detector/</guid>
				<description><![CDATA[The 801PHEx Intrinsically Safe Optical Smoke &#038; Heat Detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the optical smoke and heat elements of the detector.]]></description>
								<content:encoded><![CDATA[<p>The 801PHEx Intrinsically Safe Optical Smoke &#038; Heat Detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the optical smoke and heat elements of the detector. Software within the controller interprets the returned optical and heat values to raise an alarm or other appropriate response according to the type of programmed configuration. </p>
<p>The mode of detector may be:<br />
&#8211; Optical smoke only detector (High/ Normal/Low)<br />
&#8211; HPO smoke detector (sensitivity High, Normal or Low)<br />
&#8211; Heat only rate-of-rise (A1R) detector (no sensitivity selection)<br />
&#8211; Heat fixed temperature 60°C (A2S) (no sensitivity selection)<br />
&#8211; Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60°C (A2S)<br />
&#8211; HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60°C (A2S)</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus. </p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                 18 to 24Vdc<br />
&#8211; Queiscent Current                 400µA (max.)<br />
&#8211; Alarm Current                         3.5mA (max.)<br />
&#8211; Operating Tempearture        -25°C to +70°C<br />
&#8211; Relative Humidity                   10% to 95% (non-cond.)<br />
&#8211; FPANZ Listed                          VF/351<br />
&#8211; IECEX Certificate                    IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX 801CHEx Intrinsically Safe (I.S) Carbon Monoxide &#038; Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801chex-intrinsically-safe-i-s-carbon-monoxide-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801chex-intrinsically-safe-i-s-carbon-monoxide-heat-detector/</guid>
				<description><![CDATA[The 801CHEx Intrinsically Safe Carbon Monoxide plus Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base.]]></description>
								<content:encoded><![CDATA[<p>The 801CHEx Intrinsically Safe Carbon Monoxide plus Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the carbon monoxide and heat elements of the detector. Software within the controller is used to interpret the returned Carbon Monoxide and heat values to raise an alarm or other appropriate response according to the  programmed configuration.</p>
<p>The mode of detector may be:<br />
&#8211; Heat only detector (A1R or A2S) (sensitivity: High, Normal or Low)<br />
&#8211; Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)<br />
&#8211; Compensated Carbon Monoxide detector (sensitivity: High or Normal ) combined with heat (A1R)</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus.</p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                   18 to 24Vdc<br />
&#8211; Queiscent Current                  400µA (max.)<br />
&#8211; Alarm Current                          3.5mA (max.)<br />
&#8211; Operating Tempearture         0°C to +50°C<br />
&#8211; Relative Humidity                   15% to 90% (non-cond.)<br />
&#8211; FPANZ Listed                          VF/352<br />
&#8211; IECEX Certificate                    IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX 801HEx Intrinsically Safe (I.S) Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801hex-intrinsically-safe-i-s-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801hex-intrinsically-safe-i-s-heat-detector/</guid>
				<description><![CDATA[The 801HEx Intrinsically Safe Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base]]></description>
								<content:encoded><![CDATA[<p>The 801HEx Intrinsically Safe Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the heat element of the detector. Software within the controller is used to interpret the returned heat values to raise an alarm or other appropriate response according to the programmed configuration.</p>
<p>The mode of detector may be:<br />
&#8211; EN54-5 A1R, rate-of-rise normal ambient<br />
&#8211; EN54-5 A2S, fixed 60°C<br />
&#8211; EN54-5 CR, rate-of-rise high ambient</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus.</p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                     18 to 24Vdc<br />
&#8211; Queiscent Current                    400µA (max.)<br />
&#8211; Alarm Current                            3.5mA (max.)<br />
&#8211; Operating Tempearture           -25°C to +70°C<br />
&#8211; Relative Humidity                      10% to 95% (non-cond.)<br />
&#8211; FPANZ Listed                             VF/216<br />
&#8211; IECEX Certificate                       IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>814CH MX Carbon Monoxide/Heat Detector c/w coating Thermistor (UK)</title>
		<link>http://fireandsafetywa.com.au/product/814ch-mx-carbon-monoxide-heat-detector-c-w-coating-thermistor-uk/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/814ch-mx-carbon-monoxide-heat-detector-c-w-coating-thermistor-uk/</guid>
				<description><![CDATA[The 814CH is a state-of-the-art combined CO and heat detector that allows a full set of detection modes to be implemented in the MX fire alarm panels to suit most fire detection applications. The 814CH is particularly well suited to areas and applications where smoke detector positioning is difficult or where smoke detectors are prone to false alarm.]]></description>
								<content:encoded><![CDATA[<p>The 814CH is a state-of-the-art combined CO and heat detector that allows a full set of detection modes to be implemented in the MX fire alarm panels to suit most fire detection applications. The 814CH is particularly well suited to areas and applications where smoke detector positioning is difficult or where smoke detectors are prone to false alarm. The 814CH uses a reliable electrochemical cell for the detection of CO. The integrated heat sensor monitors rate-of-rise and fixed temperature and has been tested as a stand alone heat detector. </p>
<p>The 814CH can operate in a wide variety of applications where combined risks mean that heat or CO detection alone would be insufficient. The 814CH has all the features of MX VIRTUAL detectors including self verification, temperature and CO level indication and superior service functions.</p>
<p>Specifications<br />
&#8211; Operating Voltage                20 to 40Vdc<br />
&#8211; Quiescent Current               275µA (typ.)<br />
&#8211; Alarm Current                       10mA with LED on<br />
&#8211; Remote Indicator                 Tyco E500 Mk2<br />
&#8211; Relative Humidity                 15% to 90% (n/cond)<br />
&#8211; Ambient Temperature         0°C to +50°C*<br />
&#8211; Dimensions                         109 dia x 43 h mm<br />
&#8211; Weight                                    88g<br />
&#8211; FPANZ Listed                        VF/337</p>
<p>* The 814CH may be operated between 0 and -20°C for short periods but with reduced performance</p>
]]></content:encoded>
										</item>
		<item>
		<title>814PH MX Photo &#038; Heat Multi Detector c/w coating Thermistor (UK)</title>
		<link>http://fireandsafetywa.com.au/product/814ph-mx-photo-heat-multi-detector-c-w-coating-thermistor-uk/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/814ph-mx-photo-heat-multi-detector-c-w-coating-thermistor-uk/</guid>
				<description><![CDATA[The 814P is a state-of-the-art smoke detector using a photoelectric sensor which, in conjunction with the MX fire indicator panel (CIE), suits most fire detection applications including smoke management systems. The smoke sensors incorporate a unique]]></description>
								<content:encoded><![CDATA[<p>The 814P is a state-of-the-art smoke detector using a photoelectric sensor which, in conjunction with the MX fire indicator panel (CIE), suits most fire detection applications including smoke management systems. The smoke sensors incorporate a unique<br />
“mousehole” design optical chamber with superior signal to noise ratio providing high resilience to dust and dirt which means reduced service costs. A unique chamber cover actually draws slow moving smoke into the chamber to provide a more responsive detector.</p>
<p>The 814PH adds a heat sensor which allows a full set of detection modes to be implemented in the MX CIE. The heat sensor monitors temperature and has been tested as a detector in its own right. The 814P &#038; 814PH have all the features of MX VIRTUAL detectors including self verification, temperature and smoke level indication and superior service functions.</p>
<p>Specifications<br />
&#8211; Operating Voltage           20 to 40Vdc<br />
&#8211; Quiescent Current          275µA (typ.)<br />
&#8211; Alarm Current                  10mA with LED on<br />
&#8211; Remote Indicator            Tyco E500 Mk2<br />
&#8211; Relative Humidity            10% to 95% (n/cond)<br />
&#8211; Ambient Temp.                &#8211; 25°C to +70°C<br />
&#8211; Dimensions                     109 dia x 43h mm<br />
&#8211; Weight                               76g<br />
&#8211; ActivFire Listed                afp-1424<br />
&#8211; FPANZ Listed                  VF/335</p>
]]></content:encoded>
										</item>
		<item>
		<title>850PH MX Addr Photo Heat Detector c/w Isolator</title>
		<link>http://fireandsafetywa.com.au/product/850ph-mx-addr-photo-heat-detector-c-w-isolator/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/850ph-mx-addr-photo-heat-detector-c-w-isolator/</guid>
				<description><![CDATA[With its ability to detect a wide range of fires from flaming to smouldering types, the 850PH combined smoke and heat multi-sensor detector is the preferred choice for a range of applications including industrial, retail and office environments.]]></description>
								<content:encoded><![CDATA[<p>With its ability to detect a wide range of fires from flaming to smouldering types, the 850PH combined smoke and heat multi-sensor detector is the preferred choice for a range of applications including industrial, retail and office environments. It can operate in a  number of approved modes and sensitivities that can be dynamically selected to suit different environmental conditions. The heat sensor monitors rate-of-rise and fixed temperature and has been tested as a fire detector in its own right.</p>
<p>Specifications<br />
&#8211; Operating Voltage                     20 to 40Vdc<br />
&#8211; Quiescent Current                    330µA (typ.)<br />
&#8211; Ambient Temperature              -25°C to +70°C<br />
&#8211; Relative Humidity                     10% to 95% (non-cond)<br />
&#8211; Dimensions                              109 dia x 43h mm<br />
&#8211; Weight                                         76g<br />
&#8211; ActivFire Listed                             afp-2930<br />
&#8211; FPANZ Listed                               VF/363</p>
]]></content:encoded>
										</item>
		<item>
		<title>850H MX Addr Heat Detector c/w Isolator</title>
		<link>http://fireandsafetywa.com.au/product/850h-mx-addr-heat-detector-c-w-isolator/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/850h-mx-addr-heat-detector-c-w-isolator/</guid>
				<description><![CDATA[The 850H is a flexible cost-effective addressable heat detector with most of the features of MX VIRTUAL detectors. The 850H reports the temperature to the MX fire alarm panel which allows various detection modes]]></description>
								<content:encoded><![CDATA[<p>The 850H is a flexible cost-effective addressable heat detector with most of the features of MX VIRTUAL detectors. The 850H reports the temperature to the MX fire alarm panel which allows various detection modes. The 850H uses a high quality thermistor with very low thermal mass. This allows the detector to function as a heat detector as well as providing a fast and accurate temperature display.</p>
<p>Specifications<br />
&#8211; Operating Voltage                20 to 40Vdc<br />
&#8211; Quiescent Current               290µA (typ.)<br />
&#8211; Ambient Temperature         -25°C to +70°C<br />
&#8211; Relative Humidity                 10% to 95% (non-cond.)<br />
&#8211; Dimensions                          109 dia x 43h mm<br />
&#8211; Weight                                     81g<br />
&#8211; ActivFire Listed                      afp-2927<br />
&#8211; FPANZ Listed                        VF/218</p>