	<title>Flame &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/flame/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:30:17 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Flame &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>601FEX Conventional Flame Detector Intrinsically Safe</title>
		<link>http://fireandsafetywa.com.au/product/601fex-conventional-flame-detector-intrinsically-safe/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/601fex-conventional-flame-detector-intrinsically-safe/</guid>
				<description><![CDATA[The 601FEx point type flame detectors are part of the 600 series of non-addressable detectors. The 601FEx is a full featured flame detector for indoor use.]]></description>
								<content:encoded><![CDATA[<p>The 601FEx point type flame detectors are part of the 600 series of non-addressable detectors. The 601FEx is a full featured flame detector for indoor use. It has a high degree of false alarm immunity. The 601FEx and it is designed for connection to a conventional zone of point type fire detectors that may include any mix of detection technologies.  The 601FEx is an intrinsically safe version intended for use in hazardous atmospheres and must be connected via a suitable isolator or shunt diode safety barrier in a certified Intrinsically Safe system.</p>
<p>Specifications<br />
&#8211; Operating Voltage                16 to 28Vdc<br />
&#8211; Operating Current                300 µA (max.)<br />
&#8211; Alarm Current                       30mA @ 15Vdc<br />
&#8211; Operating Temp                   -20°C to +70°C<br />
&#8211; Relative Humidity                 90% (non-cond.)*<br />
&#8211; Dimensions                          108 dia x 22 H mm<br />
&#8211; Weight                                    110g<br />
&#8211; Range                                     0.1m2 n-heptane @ 20m<br />
                                                   0.4m2 n-heptane @ 50m<br />
&#8211; Field of View                          100°<br />
&#8211; ATEX Certificate                    BASEEFA03ATEX0422X<br />
&#8211; ATEX Code                            Ex II 1 G<br />
&#8211; Cenelec Code                      EEx ia IIC T5<br />
&#8211; IECEX Certificate                  BAS 07.0075X</p>
<p>*  90% RH continuous; 99% RH (non-cond.) intermittent operation</p>
]]></content:encoded>
										</item>
		<item>
		<title>S100/S200 Bracket Assembly Stainless Steel for use with S100/S200 Flame Detectors</title>
		<link>http://fireandsafetywa.com.au/product/s100-s200-bracket-assembly-stainless-steel-for-use-with-s100-s200-flame-detectors/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/s100-s200-bracket-assembly-stainless-steel-for-use-with-s100-s200-flame-detectors/</guid>
				<description><![CDATA[Stainlesss Steel breacket assy for with all S100/200 Series detectors]]></description>
								<content:encoded><![CDATA[<p>Stainlesss Steel breacket assy for with all S100/200 Series detectors</p>
]]></content:encoded>
										</item>
		<item>
		<title>T210 Adaptor for use with S200 Series Detectors</title>
		<link>http://fireandsafetywa.com.au/product/t210-adaptor-for-use-with-s200-series-detectors/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/t210-adaptor-for-use-with-s200-series-detectors/</guid>
				<description><![CDATA[T210+ Adaptor for S200 Detectors]]></description>
								<content:encoded><![CDATA[<p>T210+ Adaptor for S200 Detectors</p>
<p>Note that parts 592.001.016 and 592.001.014 are required to rest S200 Series Detectors</p>
]]></content:encoded>
										</item>
		<item>
		<title>T210 Test Source for S200 Series Detectors (Need X704 &#038; X100/X101)</title>
		<link>http://fireandsafetywa.com.au/product/t210-test-source-for-s200-series-detectors-need-x704-x100-x101/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/t210-test-source-for-s200-series-detectors-need-x704-x100-x101/</guid>
				<description><![CDATA[T210+ Test Source for use with SOLO 704 Adaptor Tube B and SOLO100/101 poles]]></description>
								<content:encoded><![CDATA[<p>T210+ Test Source for use with SOLO 704 Adaptor Tube B and SOLO100/101 poles</p>
<p>Note that parts 592.001.016 and 592.001.014 are required to rest S200 Series Detectors</p>