<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Detector &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/detector/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Wed, 02 Mar 2022 02:54:34 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Detector &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TrueAlarm Base with Remote LED O/P</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</guid>
				<description><![CDATA[TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds.]]></description>
								<content:encoded><![CDATA[<p>TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds. Since TrueAlarm detectors use the same base, different detector types can be easily interchanged to meet specific location requirements, for example, during building construction, or when conditions are temporarily dusty. Instead of covering the smoke  detectors(causing them to be disabled), heat detectors may be installed without reprogramming the CIE. Although the CIE will indicate an incorrect detector type, the heat detector will operate at a default sensitivity maintaining building protection at that location. </p>
<p>The 4098-9789EAP can be used in areas that may experience an increased moisture level, eg under eaves</p>
<p>Specifications<br />
&#8211; Operating Voltage                   24 to 40Vdc*<br />
&#8211; Quiescent Current (max)       400µA<br />
&#8211; Alarm Current (max)               3.2mA<br />
&#8211; Relative Humidity                    10% to 95% (n/cond)<br />
&#8211; Ambient Temperature             0 to +55°C<br />
&#8211; ActivFire Listed                         afp-1225 &#038; 1246</p>
<p>* MAPNET II or IDNet auto select</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm Base with Sounder</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</guid>
				<description><![CDATA[The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics.]]></description>
								<content:encoded><![CDATA[<p>The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics. Used in  conjunction with the Simplex 4100 panel, the 9714E has a high degree of false alarm immunity thanks to advanced algorithms. The detector mounts on the 4098-9789 addressable base or 4098-9794 sounder base. An optional remote LED can also be fitted.</p>
<p>Specifications<br />
&#8211; Operating Voltage                      24 to 40Vdc*<br />
&#8211; Quiescent Current (max)          100µA<br />
&#8211; Alarm Current-relay active         24mA<br />
&#8211; External Output Drive (max)      5mA<br />
&#8211; Relative Humidity                        10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                -9°C to +50°C<br />
&#8211; Air Velocity                                    0 to 610m/min<br />
&#8211; Sensitivity                                      4 to 6% Obs/m<br />
&#8211; ActivFire Listed                            afp-1225</p>
<p>* MAPNET II or IDNet auto select w/data</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm IDNET Isolator Base</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-idnet-isolator-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-idnet-isolator-base/</guid>
				<description><![CDATA[The 4098-9793 isolator base accepts Simplex TrueAlarm analog sensors and provides communications isolation to improve installation convenience and increase system integrity.]]></description>
								<content:encoded><![CDATA[<p>The 4098-9793 isolator base accepts Simplex TrueAlarm analog sensors and provides communications isolation to improve installation convenience and increase system integrity. An internal isolation relay allows a compatible c.i.e. to separate shorted  communications wiring from functioning wiring to optimise the available sensors or other IDNet addressable devices. The isolator base’s status is communicated to the FIP,  allowing it to assist in identifying the location of the shorted wiring. During installation, earth faults frequently occur. Finding these faults normally requires extensive wiring disconnection. With the  4098-9793 isolator base, earth faults on the IDNet communications lines can be quickly located to assist in their repair and to restore the system wiring<br />
to normal.</p>
<p>Specifications<br />
&#8211; Operating Voltage                            24 to 40Vdc*<br />
&#8211; Input Voltage                                     18.9 to 32Vdc<br />
&#8211; Current (max.@ 24Vdc)                  500µA<br />
&#8211; Supervisory Resistor (9101)          3k3 Ohm 1W<br />
&#8211; Dimensions (HWD)                         105 x 105 x 35mm<br />
&#8211; Relative Humidity                              10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                       -9°C to +50°C</p>
<p>* IDNet, 1 address per base</p>
]]></content:encoded>
										</item>
		<item>
		<title>Housing Without Relay (includes photo sensor)</title>
		<link>http://fireandsafetywa.com.au/product/housing-without-relay-includes-photo-sensor/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/housing-without-relay-includes-photo-sensor/</guid>
				<description><![CDATA[The TrueAlarm duct sampling unit detects the presence of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct and air is directed to a 4098-9714EA smoke sensor mounted in the housing.]]></description>
								<content:encoded><![CDATA[<p>The TrueAlarm duct sampling unit detects the presence of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct and air is directed to a 4098-9714EA smoke sensor mounted in the housing. These duct housings provide the high reliability performance of TrueAlarm analog sensing featuring  programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation. The TrueAlarm Duct Sampling Unit require only two<br />
wires for both communications and power.</p>
<p>Specifications<br />
&#8211; Operating Voltage                   18 to 40Vdc*<br />
&#8211; LED Current                             600µA**<br />
&#8211; Air Velocity                                1.5 to 20 m/s<br />
&#8211; Relative Humidity                    10% to 95% (n/cond)<br />
&#8211; Operating Temperature         0 to +50°C<br />
4098-9753 with auxiliary relay<br />
&#8211; Relay Coil Voltage                  18 to 32Vdc<br />
&#8211; Quiescent Current                  240µA @ 24Vdc<br />
&#8211; Alarm Current                          32mA @ 24Vdc<br />
&#8211; Contact Rating                        1A @ 28Vdc (pwr limit)<br />
-Contact Rating                         0.5A @ 120VAC (resist)<br />
&#8211; ActivFire Listed                        afp-1354</p>
<p>* MAPNET II<br />
** No impact on alarm current</p>
]]></content:encoded>
										</item>
		<item>
		<title>Adapter between S100 and XM69 Changer</title>
		<link>http://fireandsafetywa.com.au/product/adapter-between-s100-and-xm69-changer/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/adapter-between-s100-and-xm69-changer/</guid>
				<description><![CDATA[SOLO704 Adaptor tube B - adapts SOLO100/101 pole sets for TYCO detector changers and testers]]></description>
								<content:encoded><![CDATA[<p>SOLO704 Adaptor tube B &#8211; adapts SOLO100/101 pole sets for TYCO detector changers and testers</p>
]]></content:encoded>
										</item>
		<item>
		<title>800RT MX Detector Removal Tool</title>
		<link>http://fireandsafetywa.com.au/product/800rt-mx-detector-removal-tool/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/800rt-mx-detector-removal-tool/</guid>
				<description><![CDATA[800RT M600/M800 Detector removal tool. Requires Adaptor B and SOLO 100 pole]]></description>
								<content:encoded><![CDATA[<p>800RT M600/M800 Detector removal tool. Requires Adaptor B and SOLO 100 pole</p>
]]></content:encoded>
										</item>
		<item>
		<title>Solo Test Smoke &#8211; Aerosol Can</title>
		<link>http://fireandsafetywa.com.au/product/solo-test-smoke-aerosol-can/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/solo-test-smoke-aerosol-can/</guid>
				<description><![CDATA[Solo Test Smoke 250ml can]]></description>
								<content:encoded><![CDATA[<p>Solo Test Smoke 250ml can</p>
]]></content:encoded>
										</item>
		<item>
		<title>Brandax VS Smoke Emitter Pack of 5 (3-4 Minute Burn Time)</title>
		<link>http://fireandsafetywa.com.au/product/brandax-vs-smoke-emitter-pack-of-5-3-4-minute-burn-time/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/brandax-vs-smoke-emitter-pack-of-5-3-4-minute-burn-time/</guid>
				<description><![CDATA[Brandax VS Smoke Cartridge, 5 60g cartridges, dia 32x62mm, 55m3 smoke vol, 180-240s burn time]]></description>
								<content:encoded><![CDATA[<p>Brandax VS Smoke Cartridge, 5 60g cartridges, dia 32x62mm, 55m3 smoke vol, 180-240s burn time</p>
]]></content:encoded>
										</item>
		<item>
		<title>Ventilax Smoke Emitter Pack of 5  (4 Minute Burn Time)</title>
		<link>http://fireandsafetywa.com.au/product/ventilax-smoke-emitter-pack-of-5-4-minute-burn-time/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/ventilax-smoke-emitter-pack-of-5-4-minute-burn-time/</guid>
				<description><![CDATA[Ventilax Smoke Cartridge, 5 60g cartridges, dia 18x62mm, 17m3 smoke vol, 180-240s burn time]]></description>
								<content:encoded><![CDATA[<p>Ventilax Smoke Cartridge, 5 60g cartridges, dia 18x62mm, 17m3 smoke vol, 180-240s burn time</p>
]]></content:encoded>
										</item>
		<item>
		<title>Splintex Smoke Match Pack 25 Burn Time 25 Seconds</title>
		<link>http://fireandsafetywa.com.au/product/splintex-smoke-match-pack-25-burn-time-25-seconds/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/splintex-smoke-match-pack-25-burn-time-25-seconds/</guid>
				<description><![CDATA[Splintax Smoke Matches, 25 1g matches, 0.7m3 smoke vol, 25s burn time]]></description>
								<content:encoded><![CDATA[<p>Splintax Smoke Matches, 25 1g matches, 0.7m3 smoke vol, 25s burn time</p>
]]></content:encoded>
										</item>
	</channel>
</rss>
