<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Base &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/base/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:31:46 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Base &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TrueAlarm Base with Remote LED O/P</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</guid>
				<description><![CDATA[TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds.]]></description>
								<content:encoded><![CDATA[<p>TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds. Since TrueAlarm detectors use the same base, different detector types can be easily interchanged to meet specific location requirements, for example, during building construction, or when conditions are temporarily dusty. Instead of covering the smoke  detectors(causing them to be disabled), heat detectors may be installed without reprogramming the CIE. Although the CIE will indicate an incorrect detector type, the heat detector will operate at a default sensitivity maintaining building protection at that location. </p>
<p>The 4098-9789EAP can be used in areas that may experience an increased moisture level, eg under eaves</p>
<p>Specifications<br />
&#8211; Operating Voltage                   24 to 40Vdc*<br />
&#8211; Quiescent Current (max)       400µA<br />
&#8211; Alarm Current (max)               3.2mA<br />
&#8211; Relative Humidity                    10% to 95% (n/cond)<br />
&#8211; Ambient Temperature             0 to +55°C<br />
&#8211; ActivFire Listed                         afp-1225 &#038; 1246</p>
<p>* MAPNET II or IDNet auto select</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm Base with Sounder</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</guid>
				<description><![CDATA[The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics.]]></description>
								<content:encoded><![CDATA[<p>The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics. Used in  conjunction with the Simplex 4100 panel, the 9714E has a high degree of false alarm immunity thanks to advanced algorithms. The detector mounts on the 4098-9789 addressable base or 4098-9794 sounder base. An optional remote LED can also be fitted.</p>
<p>Specifications<br />
&#8211; Operating Voltage                      24 to 40Vdc*<br />
&#8211; Quiescent Current (max)          100µA<br />
&#8211; Alarm Current-relay active         24mA<br />
&#8211; External Output Drive (max)      5mA<br />
&#8211; Relative Humidity                        10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                -9°C to +50°C<br />
&#8211; Air Velocity                                    0 to 610m/min<br />
&#8211; Sensitivity                                      4 to 6% Obs/m<br />
&#8211; ActivFire Listed                            afp-1225</p>
<p>* MAPNET II or IDNet auto select w/data</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm IDNET Isolator Base</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-idnet-isolator-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-idnet-isolator-base/</guid>
				<description><![CDATA[The 4098-9793 isolator base accepts Simplex TrueAlarm analog sensors and provides communications isolation to improve installation convenience and increase system integrity.]]></description>
								<content:encoded><![CDATA[<p>The 4098-9793 isolator base accepts Simplex TrueAlarm analog sensors and provides communications isolation to improve installation convenience and increase system integrity. An internal isolation relay allows a compatible c.i.e. to separate shorted  communications wiring from functioning wiring to optimise the available sensors or other IDNet addressable devices. The isolator base’s status is communicated to the FIP,  allowing it to assist in identifying the location of the shorted wiring. During installation, earth faults frequently occur. Finding these faults normally requires extensive wiring disconnection. With the  4098-9793 isolator base, earth faults on the IDNet communications lines can be quickly located to assist in their repair and to restore the system wiring<br />
to normal.</p>
<p>Specifications<br />
&#8211; Operating Voltage                            24 to 40Vdc*<br />
&#8211; Input Voltage                                     18.9 to 32Vdc<br />
&#8211; Current (max.@ 24Vdc)                  500µA<br />
&#8211; Supervisory Resistor (9101)          3k3 Ohm 1W<br />
&#8211; Dimensions (HWD)                         105 x 105 x 35mm<br />
&#8211; Relative Humidity                              10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                       -9°C to +50°C</p>
<p>* IDNet, 1 address per base</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX Programmable Relay Base</title>
		<link>http://fireandsafetywa.com.au/product/mx-programmable-relay-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-programmable-relay-base/</guid>
				<description><![CDATA[The 814RB Addressable Relay Base provides two sets of changeover volt-free relay contacts capable of switching 1A (resistive) @30Vdc.]]></description>
								<content:encoded><![CDATA[<p>The 814RB Addressable Relay Base provides two sets of changeover volt-free relay contacts capable of switching 1A (resistive) @30Vdc. The relay function is controlled by the MX fire alarm panel via the detector fitted to the 814RB. The 814RB may be mounted to the ceiling, plugged into an M614/5B Universal Base or an 5BI/814IB Isolator Base.</p>
<p>Specifications<br />
&#8211; Operating Voltage                20 to 40Vdc<br />
&#8211; Quiescent Current               50µA (max.)<br />
&#8211; Switching Current                1A @ 30Vdc max.<br />
&#8211; Indoor Applications Only<br />
&#8211; Ambient Temperature         -10°C to +55°C<br />
&#8211; Relative Humidity                 10% to 95% (n/cond)<br />
&#8211; ActivFire Listed with MX detectors<br />
&#8211; FPANZ Listed                        VF/638</p>
]]></content:encoded>
										</item>
		<item>
		<title>4B Detector Base</title>
		<link>http://fireandsafetywa.com.au/product/4b-detector-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/4b-detector-base/</guid>
				<description><![CDATA[The 4B Universal Base contains no electronics and is suitable for indoor applications of the 614 series conventional (non-addressable), 814 and 850 series analogue addressable detectors. It provides excellent space for cable access and terminations]]></description>
								<content:encoded><![CDATA[<p>The 4B Universal Base contains no electronics and is suitable for indoor applications of the 614 series conventional (non-addressable), 814 and 850 series analogue addressable detectors. It provides excellent space for cable access and terminations. It features remote LED connections and an antitamper facility. The 4B base is designed to snap-fit into the ceiling tile adaptor, or screw fix to the ceiling in the traditional manner. The Euro Mount Adaptor is a shallow (20mm deep) back box for surface mounting  applications. The 4B-6A Adaptor covers ceiling marks revealed when changing from an existing 5” or 6” base.</p>
<p>Specifications<br />
&#8211; Operating Temp.            -25°C to +75°C<br />
&#8211; Relative Humidity           10% to 95% (non cond.)<br />
&#8211; Dimensions (mm)         109 dia x 25H<br />
&#8211; Weight                               64g<br />
&#8211; ActivFire Listed with compatible detectors</p>
]]></content:encoded>
										</item>
		<item>
		<title>4B-C Continuity Base</title>
		<link>http://fireandsafetywa.com.au/product/4b-c-continuity-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/4b-c-continuity-base/</guid>
				<description><![CDATA[The 4B-C Continuity Base is used for most installations involving 850 Series detectors, as it allows the detector’s in-built short circuit isolation function to be in-circuit when the detector is fitted and ensures continuity is maintained when the detector is removed.]]></description>
								<content:encoded><![CDATA[<p>The 4B-C Continuity Base is used for most installations involving 850 Series detectors, as it allows the detector’s in-built short circuit isolation function to be in-circuit when the detector is fitted and ensures continuity is maintained when the detector is removed.</p>
<p>Specifications<br />
&#8211; Ambient Temperature           -25°C to +70°C<br />
&#8211; Relative Humidity                   10% to 95% (n/cond)<br />
&#8211; Dimensions (mm)                 109 dia x 25H<br />
&#8211; Weight                                       64g<br />
&#8211; Indoor Applications Only<br />
&#8211; ActivFire Listed with MX detectors</p>
<p>* Maximum number of devices between 5BI bases is limited to 40 for AS 1670.1-2004 systems.</p>
]]></content:encoded>
										</item>
		<item>
		<title>4B-I Isolator Base</title>
		<link>http://fireandsafetywa.com.au/product/4b-i-isolator-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/4b-i-isolator-base/</guid>
				<description><![CDATA[The 4B-I Isolator Base serves as both a base for an 814 Series MX detector and a protection device against loop short circuits, monitoring the voltage on the MX addressable loop. When a short circuit is detected, the 4B-I isolates the affected section whilst allowing the rest of the addressable loop to function normally.]]></description>
								<content:encoded><![CDATA[<p>The 4B-I Isolator Base serves as both a base for an 814 Series MX detector and a protection device against loop short circuits, monitoring the voltage on the MX addressable loop. When a short circuit is detected, the 4B-I isolates the affected section whilst allowing the rest of the addressable loop to function normally. If a detector fitted to the 4B-I exhibits a short circuit, the 4B-I will isolate both sides of the loop from the faulty device without affecting any other device on the loop. An amber LED indicator on the rim of the base illuminates whenever the short circuit isolator is activated. The 4B-I can accommodate one of the MX detectors, or serve as a base for an 814RB.</p>
<p>Specifications<br />
&#8211; Operating Voltage                    20 to 40Vdc<br />
&#8211; Quiescent Current                   80µA (max.)<br />
&#8211; Tripped Current                        3.5mA (max.)<br />
&#8211; IB Units betwn 4B-I bases     100 (max.)*<br />
&#8211; Indoor Applications Only<br />
&#8211; Ambient Temperature             -25°C to +70°C<br />
&#8211; Relative Humidity                     10% to 95% (n/cond)<br />
&#8211; ActivFire Listed with MX detectors<br />
&#8211; FPANZ Listed                             VF/650</p>
<p>* Maximum number of devices between 4BI bases is limited to 40 for AS 1670.1-2004 systems.</p>
]]></content:encoded>
										</item>
		<item>
		<title>4B-EM 4” Euro Mount Back Box</title>
		<link>http://fireandsafetywa.com.au/product/4b-em-4-euro-mount-back-box/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/4b-em-4-euro-mount-back-box/</guid>
				<description><![CDATA[The 4B Universal Base contains no electronics and is suitable for indoor applications of the 614 series conventional (non-addressable), 814 and 850 series analogue addressable detectors. It provides excellent space for cable access and terminations]]></description>
								<content:encoded><![CDATA[<p>The 4B Universal Base contains no electronics and is suitable for indoor applications of the 614 series conventional (non-addressable), 814 and 850 series analogue addressable detectors. It provides excellent space for cable access and terminations. It features remote LED connections and an antitamper facility. The 4B base is designed to snap-fit into the ceiling tile adaptor, or screw fix to the ceiling in the traditional manner. The Euro Mount Adaptor is a shallow (20mm deep) back box for surface mounting  applications. The 4B-6A Adaptor covers ceiling marks revealed when changing from an existing 5” or 6” base.</p>
<p>Specifications<br />
&#8211; Operating Temp.            -25°C to +75°C<br />
&#8211; Relative Humidity           10% to 95% (non cond.)<br />
&#8211; Dimensions (mm)         109 dia x 25H<br />
&#8211; Weight                               64g<br />
&#8211; ActivFire Listed with compatible detectors</p>
]]></content:encoded>
										</item>
		<item>
		<title>4B-DHM 4” Deck-head Mount</title>
		<link>http://fireandsafetywa.com.au/product/4b-dhm-4-deck-head-mount/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/4b-dhm-4-deck-head-mount/</guid>
				<description><![CDATA[The 4B Universal Base contains no electronics and is suitable for indoor applications of the 614 series conventional (non-addressable), 814 and 850 series analogue addressable detectors. It provides excellent space for cable access and terminations]]></description>
								<content:encoded><![CDATA[<p>The 4B Universal Base contains no electronics and is suitable for indoor applications of the 614 series conventional (non-addressable), 814 and 850 series analogue addressable detectors. It provides excellent space for cable access and terminations. It features remote LED connections and an antitamper facility. The 4B base is designed to snap-fit into the ceiling tile adaptor, or screw fix to the ceiling in the traditional manner. The Euro Mount Adaptor is a shallow (20mm deep) back box for surface mounting  applications. The 4B-6A Adaptor covers ceiling marks revealed when changing from an existing 5” or 6” base.</p>
<p>Specifications<br />
&#8211; Operating Temp.            -25°C to +75°C<br />
&#8211; Relative Humidity           10% to 95% (non cond.)<br />
&#8211; Dimensions (mm)         109 dia x 25H<br />
&#8211; Weight                               64g<br />
&#8211; ActivFire Listed with compatible detectors</p>
]]></content:encoded>
										</item>
		<item>
		<title>5B 5&#8243; Universal Isolator Mounting Base</title>
		<link>http://fireandsafetywa.com.au/product/5b-5-universal-isolator-mounting-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/5b-5-universal-isolator-mounting-base/</guid>
				<description><![CDATA[5B 5" Universal Isolator Mounting Base]]></description>
								<content:encoded><![CDATA[<p>5B 5&#8243; Universal Isolator Mounting Base</p>
]]></content:encoded>
										</item>
	</channel>
</rss>
