<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>4100 &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-tag/4100/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sat, 13 Oct 2018 09:49:25 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>4100 &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>4100ES Panel</title>
		<link>http://fireandsafetywa.com.au/product/4100es-panel/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/4100es-panel/</guid>
				<description><![CDATA[The 4100ESi compact is a preassembled single loop fire alarm control panel available off the shelf and comes equipped with he following: 1 x CPU and 4100ESi colour touch screen LCD controller with 2 Gig onboard memory card and Ethernet port 1 x 10 Amp power supply which has 5 amps available for external use [&#8230;]]]></description>
								<content:encoded><![CDATA[<p>The 4100ESi compact is a preassembled single loop fire alarm control panel available off the shelf and comes equipped with he following:<br />
1 x CPU and 4100ESi colour touch screen LCD controller with 2 Gig onboard memory card and Ethernet port<br />
1 x 10 Amp power supply which has 5 amps available for external use<br />
1 x Remote unit interface board (RUI) designed to connect LCD anunciator or remote transponder units (RTUs)<br />
1 x MX 250 device addressable loop<br />
3 x 24V outputs<br />
3 x NACs these are programmable to supply a monitored 24V output<br />
1 x AUX relay output &#8211; 2 Amp rated clean contract programmable relay<br />
3 x Brigade relay outputs<br />
Space for brigade interface (not included please choose option required)<br />
Space to house 1 x 50W tone generator and microphone</p>
]]></content:encoded>
										</item>
		<item>
		<title>Serial LCD Annunciator (4100 FIP only)</title>
		<link>http://fireandsafetywa.com.au/product/serial-lcd-annunciator-4100-fip-only/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/serial-lcd-annunciator-4100-fip-only/</guid>
				<description><![CDATA[The Simplex 4603-9101 LCD annunciator provides remote annunciation and control using an 80 character, back-lit, alphanumeric, LCD readout. Information is presented in clear, descriptive English language]]></description>
								<content:encoded><![CDATA[<p>The Simplex 4603-9101 LCD annunciator provides remote annunciation and control using an 80 character, back-lit, alphanumeric, LCD readout. Information is presented in clear, descriptive English language and includes: point status (alarm, trouble, etc.), alarm type (smoke detector, manual station, etc.), number of system alarms, supervisory conditions, and troubles, and a custom location label. Communications require a single twisted, shielded pair that supports other styles of Simplex serial annunciators on the  same wire pair. Alarm, Supervisory, and Trouble conditions are also indicated by dedicated LEDs and a tone-alert. Each condition has a dedicated acknowledge push-button switch that silences the tone-alert but leaves the LED on until all conditions in that category are restored to normal. Switch operation is either globally or individually acknowledgeable, determined by the control panel operation. Repeated operation of the appropriate acknowledge switch will scroll the LCD display showing activity in the sequence of occurrence. The tone-alert also sounds to indicate the operation of any of the push-button switches</p>
<p>Specifications<br />
&#8211; Operating Voltage              24Vdc, Loop Supplied<br />
&#8211; Operating Current               170 mA<br />
&#8211; Operating Temp                  0 to 49°C<br />
&#8211; Relative Humidity                10% to 90% (non-cond)<br />
&#8211; Standard Trim                      Steel, Painted Beige<br />
&#8211; Optional Trim                        Brushed Aluminium 4603-9111<br />
&#8211; Trim Dimensions(HW)       114 x 300 mm</p>
]]></content:encoded>
										</item>
		<item>
		<title>Simplex BACpac BACnet Portal with Ethernet Interface</title>
		<link>http://fireandsafetywa.com.au/product/simplex-bacpac-bacnet-portal-with-ethernet-interface/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-bacpac-bacnet-portal-with-ethernet-interface/</guid>
				<description><![CDATA[The 4100-6069 BACpac Ethernet module provides a supplementary communications interface that converts computer terminal information from a compatible Simplex CIE into the building automation protocol of BACnet.]]></description>
								<content:encoded><![CDATA[<p>The 4100-6069 BACpac Ethernet module provides a supplementary communications interface that converts computer terminal information from a compatible Simplex CIE into the building automation protocol of BACnet. With this module, status information from the CIE can be provided to other components of the building automation network with the detail and information format required. This allows the other systems to properly respond to fire alarm system activity in addition to the primary fire alarm response that is under the control of the CIE. </p>
<p>Specifications<br />
&#8211; Input Power                            123mA@24Vdc (c.i.e.)<br />
&#8211; Data Input from CIE              RS232 ASCII<br />
&#8211; Data Output                            BACnet IP<br />
&#8211; Operating Temperature       0°C to +45°C<br />
&#8211; Reletive Humdity                   10% to 93% (non/cond)<br />
&#8211; Dimensions (mm)                2654x51x105 (HWD)</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueStart2 test tool, comes with 24V power pack battery charger, test leads, instructions and carry bag</title>
		<link>http://fireandsafetywa.com.au/product/truestart2-test-tool-comes-with-24v-power-pack-battery-charger-test-leads-instructions-and-carry-bag/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:13 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truestart2-test-tool-comes-with-24v-power-pack-battery-charger-test-leads-instructions-and-carry-bag/</guid>
				<description><![CDATA[The Simplex TrueSTART II Test Tool is a portable battery-operated test instrument, designed to enable contractors or technicians to quickly verify that all IDNet wiring and peripheral devices are installed correctly and operating properly]]></description>
								<content:encoded><![CDATA[<p>The Simplex TrueSTART II Test Tool is a portable battery-operated test instrument, designed to enable contractors or technicians to quickly verify that all IDNet wiring and peripheral devices are installed correctly and operating properly, even before they are  connected to the 4100 fire alarm control panel. The TrueSTART II instrument uses advanced software technology to scan hundreds of addressable fire alarm system devices and pinpoint potential problems, such as ground faults, shorted wiring, or incorrect or duplicate addressing.</p>
<p>Specifications<br />
&#8211; Operating Voltage              24 to 40Vdc<br />
&#8211; Battery Life (approx.)          6 hours of testing<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        0 to +55°C</p>
]]></content:encoded>