<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MX Hazardous Detectors/Devices &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/vigilant/mx-hazardous-detectors-devices/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:29:59 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>MX Hazardous Detectors/Devices &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MX 801PHEx Intrinsically Safe (I.S) Photoelectric &#038; Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801phex-intrinsically-safe-i-s-photoelectric-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801phex-intrinsically-safe-i-s-photoelectric-heat-detector/</guid>
				<description><![CDATA[The 801PHEx Intrinsically Safe Optical Smoke &#038; Heat Detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the optical smoke and heat elements of the detector.]]></description>
								<content:encoded><![CDATA[<p>The 801PHEx Intrinsically Safe Optical Smoke &#038; Heat Detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the optical smoke and heat elements of the detector. Software within the controller interprets the returned optical and heat values to raise an alarm or other appropriate response according to the type of programmed configuration. </p>
<p>The mode of detector may be:<br />
&#8211; Optical smoke only detector (High/ Normal/Low)<br />
&#8211; HPO smoke detector (sensitivity High, Normal or Low)<br />
&#8211; Heat only rate-of-rise (A1R) detector (no sensitivity selection)<br />
&#8211; Heat fixed temperature 60°C (A2S) (no sensitivity selection)<br />
&#8211; Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60°C (A2S)<br />
&#8211; HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60°C (A2S)</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus. </p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                 18 to 24Vdc<br />
&#8211; Queiscent Current                 400µA (max.)<br />
&#8211; Alarm Current                         3.5mA (max.)<br />
&#8211; Operating Tempearture        -25°C to +70°C<br />
&#8211; Relative Humidity                   10% to 95% (non-cond.)<br />
&#8211; FPANZ Listed                          VF/351<br />
&#8211; IECEX Certificate                    IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX 801CHEx Intrinsically Safe (I.S) Carbon Monoxide &#038; Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801chex-intrinsically-safe-i-s-carbon-monoxide-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801chex-intrinsically-safe-i-s-carbon-monoxide-heat-detector/</guid>
				<description><![CDATA[The 801CHEx Intrinsically Safe Carbon Monoxide plus Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base.]]></description>
								<content:encoded><![CDATA[<p>The 801CHEx Intrinsically Safe Carbon Monoxide plus Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the carbon monoxide and heat elements of the detector. Software within the controller is used to interpret the returned Carbon Monoxide and heat values to raise an alarm or other appropriate response according to the  programmed configuration.</p>
<p>The mode of detector may be:<br />
&#8211; Heat only detector (A1R or A2S) (sensitivity: High, Normal or Low)<br />
&#8211; Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)<br />
&#8211; Compensated Carbon Monoxide detector (sensitivity: High or Normal ) combined with heat (A1R)</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus.</p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                   18 to 24Vdc<br />
&#8211; Queiscent Current                  400µA (max.)<br />
&#8211; Alarm Current                          3.5mA (max.)<br />
&#8211; Operating Tempearture         0°C to +50°C<br />
&#8211; Relative Humidity                   15% to 90% (non-cond.)<br />
&#8211; FPANZ Listed                          VF/352<br />
&#8211; IECEX Certificate                    IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX 801HEx Intrinsically Safe (I.S) Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/mx-801hex-intrinsically-safe-i-s-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-801hex-intrinsically-safe-i-s-heat-detector/</guid>
				<description><![CDATA[The 801HEx Intrinsically Safe Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base]]></description>
								<content:encoded><![CDATA[<p>The 801HEx Intrinsically Safe Heat Detector forms part of the 800Ex Intrinsically Safe Series of MX Addressable Fire Detectors. The detector plugs into a 5BEx base. The detector is designed to transmit to a remote MX fire controller, digital signals which represent the status of the heat element of the detector. Software within the controller is used to interpret the returned heat values to raise an alarm or other appropriate response according to the programmed configuration.</p>
<p>The mode of detector may be:<br />
&#8211; EN54-5 A1R, rate-of-rise normal ambient<br />
&#8211; EN54-5 A2S, fixed 60°C<br />
&#8211; EN54-5 CR, rate-of-rise high ambient</p>
<p>These detectors are designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus.</p>
<p>They are certified:<br />
&#8211; ATEX Code: Ex II 1G<br />
&#8211; IECEX Code: Ex ia IIC T5<br />
&#8211; Cenelec Code: EEx ia IIC T5</p>
<p>Specifications<br />
&#8211; Operating Voltage                     18 to 24Vdc<br />
&#8211; Queiscent Current                    400µA (max.)<br />
&#8211; Alarm Current                            3.5mA (max.)<br />
&#8211; Operating Tempearture           -25°C to +70°C<br />
&#8211; Relative Humidity                      10% to 95% (non-cond.)<br />
&#8211; FPANZ Listed                             VF/216<br />
&#8211; IECEX Certificate                       IECEX BAS 07.0063X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX CP840Ex Intrinsically Safe(I.S) Manual Callpoint</title>
		<link>http://fireandsafetywa.com.au/product/mx-cp840ex-intrinsically-safei-s-manual-callpoint/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:54 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-cp840ex-intrinsically-safei-s-manual-callpoint/</guid>
				<description><![CDATA[The CP840Ex Intrinsically Safe Waterproof Break Glass Manual Call Point is designed to monitor and signal the condition of the switch contact associated with the call point. The callpoint is designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus.]]></description>
								<content:encoded><![CDATA[<p>The CP840Ex Intrinsically Safe Waterproof Break Glass Manual Call Point is designed to monitor and signal the condition of the switch contact associated with the call point. The callpoint is designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus. </p>
<p>It is certified:<br />
&#8211; IECEX Certificate                      BAS 07.0063X<br />
&#8211; ATEX Classification                 Ex II 1 G<br />
&#8211; ATEX Certificate                        BAS01ATEX1394X<br />
&#8211; Cenelec Classification           EEx ia IIC T5</p>
<p>The CP840Ex does not comply with NZS4512.</p>
<p>Specifications<br />
&#8211; Operating Voltage                  18 to 24Vdc<br />
&#8211; Queiscent Current                  300µA (max.)<br />
&#8211; Alarm Current                          5mA (max.)<br />
&#8211; Operating Tempearture         -25°C to +70°C<br />
&#8211; Relative Humidity                   10% to 95% (non-cond.)<br />
&#8211; Dimensions (HWD)               124 x 124 x 59 mm<br />
&#8211; Ingress Protection                  IP67<br />
&#8211; ATEX Certificate                      BAS01ATEX1394X<br />
&#8211; IECEX Certificate                    BAS 07.0063X</p>