<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gas Control Equipment &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/vigilant/gas-control-equipment/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:27:03 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Gas Control Equipment &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AS4428 1 Zone Gas Control 1U Bracket</title>
		<link>http://fireandsafetywa.com.au/product/as4428-1-zone-gas-control-1u-bracket/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/as4428-1-zone-gas-control-1u-bracket/</guid>
				<description><![CDATA[Gas Control modules provide indication and control of 1-4 zones of gas extinguishing F3200 and MX4428]]></description>
								<content:encoded><![CDATA[<p>Gas Control modules provide indication and control of 1-4 zones of gas extinguishing F3200 and MX4428. They are pre-wired modules (requiring appropriate input/output modules). </p>
<p>The modules have a 12 way screw termianl block for easy termination of the field wiring for the local Gas Control Stations,gas discharged pressure switch, warning signs and gas release output.</p>
<p>Dimensions<br />
 &#8211; Height     312 mm<br />
 &#8211; Width       485 mm</p>
]]></content:encoded>
										</item>
		<item>
		<title>AS4428 4 Zone Gas Control 7U Door</title>
		<link>http://fireandsafetywa.com.au/product/as4428-4-zone-gas-control-7u-door/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/as4428-4-zone-gas-control-7u-door/</guid>
				<description><![CDATA[Gas Control Modules provide indication and control of 1-4 zones of gas extinguishing on F3200 and MX4428 CIE. They are pre-wired modules (requiring appropriate input/output modules).]]></description>
								<content:encoded><![CDATA[<p>Gas Control Modules provide indication and control of 1-4 zones of gas extinguishing on F3200 and MX4428 CIE. They are pre-wired modules (requiring appropriate input/output modules). The modules have a 12 way screw terminal block for easy termination of the field wiring for the Local Gas Control Stations, gas discharged pressure switch, warning signs and gas release output. The connection for the Alert/Evacuate warning signs is a 2-wire polarity switched output that supports up to 10 AVI Mk2 units. All outputs  can be supervised (this requires appropriate programming and configuring in the panel).</p>
<p>The gas control modules provide LEDs for each gas zone to indicate:<br />
&#8211; Gas Initiated (red)<br />
&#8211; Manual Release (red)<br />
&#8211; Gas Discharged (blue)<br />
&#8211; Gas Inhibited (yellow)<br />
&#8211; Gas Isolated (yellow)<br />
&#8211; System Inoperative (yellow)</p>
<p>A Gas Discharge Isolate switch that physically isolates both poles of the gas release actuator output is also provided for each gas zone.</p>
]]></content:encoded>
										</item>
		<item>
		<title>Local Gas Control Station Auto c/w Isolate Switch</title>
		<link>http://fireandsafetywa.com.au/product/local-gas-control-station-auto-c-w-isolate-switch/</link>
				<pubDate>Sun, 07 Oct 2018 13:26:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/local-gas-control-station-auto-c-w-isolate-switch/</guid>
				<description><![CDATA[Local Gas Control Stations (LGCS) are used in gaseous fire extinguishing systems to provide local area manual control of a release. The automatic version includes a Gas Inhibit switch, buzzer and LED, whereas the manual version (FP0572) does not.]]></description>
								<content:encoded><![CDATA[<p>Local Gas Control Stations (LGCS) are used in gaseous fire extinguishing systems to provide local area manual control of a release. The automatic version includes a Gas Inhibit switch, buzzer and LED, whereas the manual version (FP0572) does not.</p>
<p>The LGCS is fitted with a resettable no-break plastic frangible element.</p>
<p>Dimensions<br />
 &#8211; Height     192 mm<br />
 &#8211; Width       124 mm<br />
 &#8211; Depth       82 mm</p>
]]></content:encoded>
										</item>
	</channel>
</rss>
