<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Devices MX4428 &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/vigilant/devices-mx4428/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:29:44 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Devices MX4428 &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>QMO850 Quad Monitored Output</title>
		<link>http://fireandsafetywa.com.au/product/qmo850-quad-monitored-output/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/qmo850-quad-monitored-output/</guid>
				<description><![CDATA[The MX Quad Ancillary Modules form a versatile new range of multiple input and output modules for use with MX TECHNOLOGY systems*.]]></description>
								<content:encoded><![CDATA[<p>The MX Quad Ancillary Modules form a versatile new range of multiple input and output modules for use with MX TECHNOLOGY systems*. </p>
<p>&#8211; QIO850 &#8211; Quad Input / Output module – provides four monitored inputs and four relay outputs<br />
&#8211; QMO850 &#8211; Quad Monitored Output module – provides four monitored outputs<br />
&#8211; QRM850 &#8211; Quad Relay Output Module – provides four relay outputs</p>
<p>The modules are ideal for applications such as:<br />
&#8211; AS 1668 fan control interfaces<br />
&#8211; Plant or security outputs, or when large  numbers of inputs and/or outputs are required.</p>
<p>Features common to the Quad Modules are:<br />
&#8211; Built-in MX loop short-circuit isolator with fault indication at the MX1 CIE1 when operated<br />
&#8211; IR link for programming by 850EMT<br />
&#8211; Selectable interrupt operation to speed up response<br />
&#8211; Enclosed in protective plastic housing, with an optional IP66 enclosure available for applications in challenging environments<br />
&#8211; Top-hat DIN rail mounting<br />
&#8211; LED indication of each output state<br />
&#8211; 24V/48V link selectable Auxillary supply for outputs<br />
&#8211; Supervision of Auxillary supply for presence<br />
&#8211; Fault indication of stuck relay contacts &#8211; not operating when switched on.</p>
<p>Specifications<br />
 MX Loop Voltage                     20-40Vdc<br />
Quiescent Current                   1.2mA<br />
Alarm Current                           4.2mA<br />
Relay Output                             2A@30Vdc<br />
Aux. Voltage Input                    20-55Vdc<br />
Dimensions (HWD)                134 x 103 x 49 mm<br />
Weight                                        232g<br />
Ambient Temp.                         –25°C to +70°C<br />
Storage Temp.                          –40°C to +80°C<br />
Relative Humidity                     10% to 95% (n/cond.)<br />
ActivFire Listed                         afp-2320<br />
FPANZ Listed                           pending</p>
<p>*The MX Quad Ancillary Modules are not supported by the MX4428 CIE.</p>
]]></content:encoded>
										</item>
		<item>
		<title>QRM850 Quad Relay Module</title>
		<link>http://fireandsafetywa.com.au/product/qrm850-quad-relay-module/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/qrm850-quad-relay-module/</guid>
				<description><![CDATA[The MX Quad Ancillary Modules form a versatile new range of multiple input and output modules for use with MX TECHNOLOGY systems*.]]></description>
								<content:encoded><![CDATA[<p>The MX Quad Ancillary Modules form a versatile new range of multiple input and output modules for use with MX TECHNOLOGY systems*. </p>
<p>&#8211; QIO850 &#8211; Quad Input / Output module – provides four monitored inputs and four relay outputs<br />
&#8211; QMO850 &#8211; Quad Monitored Output module – provides four monitored outputs<br />
&#8211; QRM850 &#8211; Quad Relay Output Module – provides four relay outputs</p>
<p>The modules are ideal for applications such as:<br />
&#8211; AS 1668 fan control interfaces<br />
&#8211; Plant or security outputs, or when large  numbers of inputs and/or outputs are required.</p>
<p>Features common to the Quad Modules are:<br />
&#8211; Built-in MX loop short-circuit isolator with fault indication at the MX1 CIE1 when operated<br />
&#8211; IR link for programming by 850EMT<br />
&#8211; Selectable interrupt operation to speed up response<br />
&#8211; Enclosed in protective plastic housing, with an optional IP66 enclosure available for applications in challenging environments<br />
&#8211; Top-hat DIN rail mounting<br />
&#8211; LED indication of each output state<br />
&#8211; 24V/48V link selectable Auxillary supply for outputs<br />
&#8211; Supervision of Auxillary supply for presence<br />
&#8211; Fault indication of stuck relay contacts &#8211; not operating when switched on.</p>
<p>Specifications<br />
 MX Loop Voltage                     20-40Vdc<br />
Quiescent Current                   0.58mA<br />
Alarm Current                           3.6mA<br />
Relay Output                             2A@30Vdc<br />
Aux. Voltage Input                    20-55Vdc<br />
Dimensions (HWD)                134 x 103 x 49 mm<br />
Weight                                        232g<br />
Ambient Temp.                         –25°C to +70°C<br />
Storage Temp.                          –40°C to +80°C<br />
Relative Humidity                     10% to 95% (n/cond.)<br />
ActivFire Listed                         afp-2320<br />
FPANZ Listed                           pending</p>
<p>*The MX Quad Ancillary Modules are not supported by the MX4428 CIE.</p>
]]></content:encoded>
										</item>
		<item>
		<title>M520 Ancillary Cover for MX Devices</title>
		<link>http://fireandsafetywa.com.au/product/m520-ancillary-cover-for-mx-devices/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/m520-ancillary-cover-for-mx-devices/</guid>
				<description><![CDATA[MX Module Cover incl PCB cover and screws]]></description>
								<content:encoded><![CDATA[<p>MX Module Cover incl PCB cover and screws</p>
<p>Specifications<br />
&#8211; Dimensions (HWD)                    81 x 148 x 14mm<br />
&#8211; Material                                          PC/ABS</p>
]]></content:encoded>
										</item>
		<item>
		<title>LIM800 Line Isolator Module</title>
		<link>http://fireandsafetywa.com.au/product/lim800-line-isolator-module/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/lim800-line-isolator-module/</guid>
				<description><![CDATA[The LIM800 Line Isolator Module is designed to be used on the MX addressable controller loop circuits]]></description>
								<content:encoded><![CDATA[<p>The LIM800 Line Isolator Module is designed to be used on the MX addressable controller loop circuits. It monitors the line condition and when detecting a short circuit will isolate the affected section whilst allowing the rest of the addressing circuit to function normally. The purpose of the LIM800 Line Isolator Module is to ensure that, on a looped addressable system, no short circuit fault can disable more detection devices than would be lost on a conventional nonaddressable fire circuit.  </p>
<p>Specifications<br />
&#8211; Operating Voltage                 20 to 40Vdc*<br />
&#8211; Current Loading<br />
   &#8211; Input Current                       80µA max. (normal)<br />
                                                    3.5mA max. (tripped)<br />
&#8211; Max. Series Resistance      0.25 Ohm**<br />
&#8211; Ambient Temp                      -25°C to +70°C<br />
&#8211; Relative Humidity                 10% to 95% (n/cond)<br />
&#8211; Dimensions (HWD)             61 x 84 x 25mm<br />
&#8211; ActivFire Listed                      afp-1446<br />
&#8211; FPANZ Listed                         VF/657</p>
<p>*    MX addressable loop voltage.<br />
**  Isolator normal.</p>
]]></content:encoded>
										</item>
		<item>
		<title>MIO800 DIN Rail Mounting Kit</title>
		<link>http://fireandsafetywa.com.au/product/mio800-din-rail-mounting-kit/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mio800-din-rail-mounting-kit/</guid>
				<description><![CDATA[DIN Rail Mountng Kit]]></description>
								<content:encoded><![CDATA[<p>DIN Rail Mounting Kit</p>
<p>Specifications<br />
&#8211; Dimensions (HWD)              78 x113 x 31 mm<br />
&#8211; Material                                    PC/ABS</p>
]]></content:encoded>
										</item>
		<item>
		<title>D800 Ancillary Housing  &#8211; IP65 Enclosure for MX Modules</title>
		<link>http://fireandsafetywa.com.au/product/d800-ancillary-housing-ip65-enclosure-for-mx-modules/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/d800-ancillary-housing-ip65-enclosure-for-mx-modules/</guid>
				<description><![CDATA[The D800 Ancillary Housing provides an IP55 rated enclosure for all MX modules. It incorporates a window to view the module LED.]]></description>
								<content:encoded><![CDATA[<p>The D800 Ancillary Housing provides an IP55 rated enclosure for all MX modules. It incorporates a window to view the module LED.</p>
<p>Specifications<br />
Dimensions (HWD)                140 x120 x70 mm<br />
Material                                      PC/ABS<br />
Ingress Protection                   IP55</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX Module Back Box</title>
		<link>http://fireandsafetywa.com.au/product/mx-module-back-box/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-module-back-box/</guid>
				<description><![CDATA[MX Module Back Box]]></description>
								<content:encoded><![CDATA[<p>Double Gang Back Box</p>
<p>Specifications<br />
Dimensions (HWD)                85 x 146 x 38 mm<br />
Material                                      PC/ABS</p>
]]></content:encoded>
										</item>
		<item>
		<title>MIO800 Multi Input Output Module (can use on 4100ESi)</title>
		<link>http://fireandsafetywa.com.au/product/mio800-multi-input-output-module-can-use-on-4100esi/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mio800-multi-input-output-module-can-use-on-4100esi/</guid>
				<description><![CDATA[The MIO800 Multi-Input Output Module allows multiple input and output connections to be made between external equipment and the MX DIGITAL loop. Three inputs and two outputs are provided.]]></description>
								<content:encoded><![CDATA[<p>The MIO800 Multi-Input Output Module allows multiple input and output connections to be made between external equipment and the MX DIGITAL loop. Three inputs and two outputs are provided. Each input and output can be programmed independently to provide customised functionality. An IP55 rated D800 style housing can be used as the standard enclosure, with the option of a DIN-rail mounting kit for in-cabinet installation.</p>
<p>Specifications<br />
&#8211; Operating Voltage                20 to 40Vdc*<br />
&#8211; Quiescent Current               480µA (max.)<br />
&#8211; Alarm Current                       3mA (max, LED on)<br />
&#8211; Relay Contact                       2A @ 24Vdc (max.)<br />
&#8211; Ambient Temp                      -25 to +70°C<br />
&#8211; Relative Humidity                 10% to 95% (n/cond)<br />
&#8211; Dimensions (HWD)             72 x 110 x 18mm<br />
&#8211; ActivFire Listed                      afp-2320<br />
&#8211; FPANZ Listed                         VF/655</p>
<p>*   MX addressable loop voltage</p>
]]></content:encoded>
										</item>
		<item>
		<title>VIO800 VESDA Interface Module c/w Bracket (can use on 4100ESi )</title>
		<link>http://fireandsafetywa.com.au/product/vio800-vesda-interface-module-c-w-bracket-can-use-on-4100esi/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/vio800-vesda-interface-module-c-w-bracket-can-use-on-4100esi/</guid>
				<description><![CDATA[The VIO800 is an arrangement of the MIO800 Addressable Multi-I/O Module supplied ready to be fitted on to a VESDA LaserPLUS™ or Laser SCANNER]]></description>
								<content:encoded><![CDATA[<p>The VIO800 is an arrangement of the MIO800 Addressable Multi-I/O Module supplied ready to be fitted on to a VESDA LaserPLUS<img src="https://s.w.org/images/core/emoji/12.0.0-1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> or Laser SCANNER .The MIO800’s inputs and outputs are wired to the relay outputs and control inputs of the LaserPLUS or Laser SCANNER to allow compatible MX c.i.e. to monitor and control the VESDA units.</p>
<p>Specifications<br />
&#8211; Operating Voltage                 20 to 40Vdc*<br />
&#8211; Quiescent Current                480µA (max.)<br />
&#8211; Operated Current                  3mA (max, LED on)<br />
&#8211; Relay Contact                        2A @ 24Vdc (max.)<br />
&#8211; Ambient Temp                       -25 to +70°C<br />
&#8211; Relative Humidity                  10% to 95% (n/cond)<br />
&#8211; Dimensions PCB (HWD)     72 x 110 x 18mm<br />
&#8211; ActivFire Listed                       afp-2320<br />
&#8211; FPANZ Listed                         VF/655</p>
<p>* MX addressable loop voltage</p>
]]></content:encoded>
										</item>
		<item>
		<title>Dual Detector Module DDM800 (can use on 4100ESi)</title>
		<link>http://fireandsafetywa.com.au/product/dual-detector-module-ddm800-can-use-on-4100esi/</link>
				<pubDate>Sun, 07 Oct 2018 13:29:25 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/dual-detector-module-ddm800-can-use-on-4100esi/</guid>
				<description><![CDATA[The DDM800 may be used to connect two circuits of conventional 20V detectors and interface them with an MX addressable fire alarm system.]]></description>
								<content:encoded><![CDATA[<p>The DDM800 Detector Module designed to monitor and signal alarms from<br />
&#8211; one or two conventional 2-wire circuits<br />
&#8211; one or two 4-20mA sensors (MX4428 only).</p>
<p>The DDM800 may be used to connect two circuits of conventional 20V detectors and interface them with an MX addressable fire alarm system.  The DDM800 can be loop powered and use the Tyco 614 series detectors, or use an external 24Vdc supply allowing a wide range of detectors to be used and be electrically isolated from the MX loop . In 4-20mA mode the DDM800 can support a single 4-20mA source on each circuit, operating in either current sink or current source mode</p>
<p>Specifications<br />
&#8211; Operating Voltage              20 to 40Vdc*<br />
&#8211; Quiescent Current             1.5mA (LV. mode)<br />
&#8211; Loop Alarm Current           2.8mA (max.)<br />
&#8211; Ambient Temp                    -25°C to +70°C<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Detector Load                     3mA (max per input)<br />
&#8211; Detector ELD                       4k7 Ohm<br />
&#8211; External Supply                   21.9 to 29Vdc**<br />
&#8211; Ext. Current/Circuit             10mA (+ Det. Load)<br />
&#8211; Ext. Alarm Current              52mA***<br />
&#8211; Dimensions (HWD)           61 x 84 x 25mm<br />
&#8211; ActivFire Listed                    afp-1446<br />
&#8211; FPANZ Listed                      VF/666</p>
<p>*      MX addressable loop voltage<br />
**    Voltage restrictions for some detectors<br />
***   External Supply Alarm / Short Circuit</p>
]]></content:encoded>