<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Detectors MX Bases &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/vigilant/detectors-mx-bases/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:29:06 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Detectors MX Bases &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>5B 5&#8243; Universal Isolator Mounting Base</title>
		<link>http://fireandsafetywa.com.au/product/5b-5-universal-isolator-mounting-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/5b-5-universal-isolator-mounting-base/</guid>
				<description><![CDATA[5B 5" Universal Isolator Mounting Base]]></description>
								<content:encoded><![CDATA[<p>5B 5&#8243; Universal Isolator Mounting Base</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX Programmable Relay Base</title>
		<link>http://fireandsafetywa.com.au/product/mx-programmable-relay-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-programmable-relay-base/</guid>
				<description><![CDATA[The 814RB Addressable Relay Base provides two sets of changeover volt-free relay contacts capable of switching 1A (resistive) @30Vdc.]]></description>
								<content:encoded><![CDATA[<p>The 814RB Addressable Relay Base provides two sets of changeover volt-free relay contacts capable of switching 1A (resistive) @30Vdc. The relay function is controlled by the MX fire alarm panel via the detector fitted to the 814RB. The 814RB may be mounted to the ceiling, plugged into an M614/5B Universal Base or an 5BI/814IB Isolator Base.</p>
<p>Specifications<br />
&#8211; Operating Voltage                20 to 40Vdc<br />
&#8211; Quiescent Current               50µA (max.)<br />
&#8211; Switching Current                1A @ 30Vdc max.<br />
&#8211; Indoor Applications Only<br />
&#8211; Ambient Temperature         -10°C to +55°C<br />
&#8211; Relative Humidity                 10% to 95% (n/cond)<br />
&#8211; ActivFire Listed with MX detectors<br />
&#8211; FPANZ Listed                        VF/638</p>
]]></content:encoded>
										</item>
		<item>
		<title>MX Mk2 Loop Powered Sounder Base</title>
		<link>http://fireandsafetywa.com.au/product/mx-mk2-loop-powered-sounder-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mx-mk2-loop-powered-sounder-base/</guid>
				<description><![CDATA[The 802SB/901SB Addressable Sounder Bases provide a sounder function on MX addressable systems. Designed for indoor use, they require an associated detector in order to operate, as each base is controlled by its detector.]]></description>
								<content:encoded><![CDATA[<p>The 802SB/901SB Addressable Sounder Bases provide a sounder function on MX addressable systems. Designed for indoor use, they require an associated detector in order to operate, as each base is controlled by its detector. The detector must be locked onto the sounder base using the detector locking device. Removal of the detector or loss of power to the loop will cause the sounder to cease sounding. It must be fixed to a flat ceiling or a suitable electrical backbox with 50mm fixing centres. The loop powered 802SB is identified by a white park clip. Up to fifty1 802SBs per loop may be operated at full volume at any one time. The 901SB requires an external 24Vdc supply and is identified by a blue park clip. The 802SB/901SB supports ISO8201 T3 tones.</p>
<p>Specifications<br />
&#8211; Operating Voltage                20 to 40Vdc<br />
&#8211; Quiescent Current               200µA (max.)<br />
&#8211; Alarm Current                       6.8mA (max. volume)<br />
&#8211; Sound Pressure Level        90dBA (max. volume)<br />
&#8211; Ambient Temp                      -25°C to +70°C<br />
&#8211; Relative Humidity                 10% to 95% (non cond.)<br />
&#8211; Devices per loop                  50 to 200*<br />
&#8211; ActivFire Listed with MX4428 (afp-1446)</p>
<p>* Assuming all 802SBs operate simultaneously: 50 per loop (High volume); 200 (Low). Refer to relevant manual for design limits. Note that the 802/901SB cannot plug into a 5B Base or 5BI Isolator base.</p>
]]></content:encoded>
										</item>
		<item>
		<title>SAM800 Sounder Driver Module</title>
		<link>http://fireandsafetywa.com.au/product/sam800-sounder-driver-module/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/sam800-sounder-driver-module/</guid>
				<description><![CDATA[The Sounder Addressing Beacon SAB801 and Sounder Addressable Module, SAM800 are designed to control an MX loop powered sounder base or relay base for use with compatible MX CIE]]></description>
								<content:encoded><![CDATA[<p>The Sounder Addressing Beacon SAB801 and Sounder Addressable Module, SAM800 are designed to control an MX loop powered sounder base or relay base for use with compatible MX CIE. The SAB801 has an integral high intensity red LED beacon that can be separately controlled to the base. The beacon can be configured to illuminate continuously or flash at 1Hz, although there is no facility to synchronise several SAB801 beacons. The SAB801 and SAM800 supply the address decoding in place of a detector, thus providing a remotely controlled beacon and sounder when used in conjunction with an 802SB.</p>
<p>Specifications<br />
&#8211; Quiescent Current                250µA<br />
&#8211; Alarm Current                        250µA1*<br />
&#8211; Max. device/Loop                  200/250**<br />
&#8211; Flash Rate<br />
&#8211; Dims (Dia.x H mm)              108 x 22<br />
&#8211; Weight                                     70g<br />
&#8211; Ambient Temp.                      -10°C to +55°C<br />
&#8211; Relative Humidity                  10% to 96% (non-cond.)<br />
&#8211; ActivFire Listing                      afp-1446<br />
&#8211; FPANZ Listed                         VF/656</p>
<p>* In addition to associated sounder/relay current.<br />
** Maximum number of devices between 4BI bases is limited to 40 for AS 1670.1-2004 systems.</p>
]]></content:encoded>
										</item>
		<item>
		<title>SAB801 Sounder Address LED Beacon</title>
		<link>http://fireandsafetywa.com.au/product/sab801-sounder-address-led-beacon/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/sab801-sounder-address-led-beacon/</guid>
				<description><![CDATA[The Sounder Addressing Beacon SAB801 and Sounder Addressable Module, SAM800 are designed to control an MX loop powered sounder base or relay base for use with compatible MX CIE]]></description>
								<content:encoded><![CDATA[<p>The Sounder Addressing Beacon SAB801 and Sounder Addressable Module, SAM800 are designed to control an MX loop powered sounder base or relay base for use with compatible MX CIE. The SAB801 has an integral high intensity red LED beacon that can be separately controlled to the base. The beacon can be configured to illuminate continuously or flash at 1Hz, although there is no facility to synchronise several SAB801 beacons. The SAB801 and SAM800 supply the address decoding in place of a detector, thus providing a remotely controlled beacon and sounder when used in conjunction with an 802SB.</p>
<p>Specifications<br />
&#8211; Alarm Current                        325µA1<br />
&#8211; Flash Rate                             Cont or 1Hz<br />
&#8211; Dims (Dia.x H mm)              108 x 32<br />
&#8211; Weight                                     70g<br />
&#8211; Ambient Temp.                      -10°C to +55°C<br />
&#8211; Relative Humidity                  10% to 96% (non-cond.)<br />
&#8211; FPANZ Listed                         VF/420</p>
]]></content:encoded>
										</item>
		<item>
		<title>901SB Sounder Base (Externally Powered)</title>
		<link>http://fireandsafetywa.com.au/product/901sb-sounder-base-externally-powered/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:57 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/901sb-sounder-base-externally-powered/</guid>
				<description><![CDATA[The 901SB Addressable Sounder Bases provide a sounder function on MX addressable systems. Designed for indoor use, they require an associated detector in order to operate, as each base is controlled by its detector.]]></description>
								<content:encoded><![CDATA[<p>The 901SB Addressable Sounder Bases provide a sounder function on MX addressable systems. Designed for indoor use, they require an associated detector in order to operate, as each base is controlled by its detector. The detector must be locked  onto the sounder base using the detector locking device. Removal of the detector or loss of power to the loop will cause the sounder to cease sounding. It must be fixed to a flat ceiling or a suitable electrical backbox with 50mm fixing centres.  The 901SB requires an external 24Vdc supply and is identified by a blue park clip. The 901SB supports ISO8201 T3 tones.</p>
<p>Specifications<br />
&#8211; Operating Voltage                  20 to 40Vdc<br />
&#8211; Quiescent Current                 200µA (max.)<br />
&#8211; Alarm Current                         6.8mA (max. volume)<br />
&#8211; Sound Pressure Level          90dBA (max. volume)<br />
&#8211; Ambient Temp                        -25°C to +70°C<br />
&#8211; Relative Humidity                   10% to 95% (non cond.)<br />
&#8211; Devices per loop                    50 to 200*<br />
&#8211; ActivFire Listed with MX4428 (afp-1446)</p>
<p>*  Assuming all 802SBs operate simultaneously: 50 per loop (High volume); 200 (Low). Refer to relevant manual for design limits. Note that the 802/901SB cannot plug into a 5B Base or 5BI Isolator base</p>
]]></content:encoded>
										</item>
	</channel>
</rss>