<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Detectors Conventional Smoke &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/vigilant/detectors-conventional-smoke/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Tue, 02 Aug 2022 04:48:14 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Detectors Conventional Smoke &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TYCO 614CH Conventional Carbon Monoxide Detector</title>
		<link>http://fireandsafetywa.com.au/product/tyco-614ch-conventional-carbon-monoxide-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/tyco-614ch-conventional-carbon-monoxide-detector/</guid>
				<description><![CDATA[The 614CH fire detector provides very early warning of slow smouldering fires. The CO fire detector is well suited to many applications where heat detection is insufficient but smoke detection causes unwanted alarms. As CO travels more freely than smoke, the positioning of CO fire detectors is more flexible]]></description>
								<content:encoded><![CDATA[<p>The 614CH fire detector provides very early warning of slow smouldering fires. The CO fire detector is well suited to many applications where heat detection is insufficient but smoke detection causes unwanted alarms.  As CO travels more freely than smoke, the positioning of CO fire detectors is more flexible.</p>
<p>This feature is particularly useful in large complex structures such as atria and warehouses, where positioning of smoke detectors is difficult. The 614CH has an additional mode of operation as a Class A1R  combined rate-of-rise and 60°C fixed temperature heat detector to supplement the CO detector mode to permit the detector to react to a wider range of fire types. </p>
<p>Although the 614CH has a rated service life of 10 years, in orderc for the 614CH to provide the intended level of fire detection, the detector should be checked for calibration 5 years after installation (or 5 years after re-installation following service) or within 7 years of the date of manufacture.</p>
<p>Specifications<br />
&#8211; Operating Voltage                   10 to 33Vdc<br />
&#8211; Quiescent Current                   55µA (max.)<br />
&#8211; Alarm Current                           3.2 to 67mA (50°C)*<br />
&#8211; Alarm State Voltage                 2.5 to 7.4Vdc<br />
&#8211; Alarm Threshold                      38ppm CO<br />
&#8211; Ext. Powered Load (max.)      50mA, 28Vdc<br />
&#8211; Remote Indicator                     E500 Mk2 Series<br />
&#8211; Relative Humidity                    15 to 90% (n/cond)<br />
&#8211; Ambient Temp                          0 to +50°C<br />
&#8211; Dimensions (incl. base)        127 dia x 54H (mm)<br />
&#8211; Weight                                        200g with base<br />
&#8211; FPANZ Listed                            VF/345</p>
<p>*1. 3.2mA min. for LED visibility. Max. current must be externally limited</p>
]]></content:encoded>
										</item>
		<item>
		<title>TYCO 614P Conventional Photo Optical Detector</title>
		<link>http://fireandsafetywa.com.au/product/tyco-614p-conventional-photo-optical-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/tyco-614p-conventional-photo-optical-detector/</guid>
				<description><![CDATA[The 614P is capable of detecting the visible smoke produced by materials which smoulder or burn slowly, i.e. soft furnishings, plastic foam etc. or ‘smoke’ produced by overheated but unburnt PVC.]]></description>
								<content:encoded><![CDATA[<p>The 614P is capable of detecting the visible smoke produced by materials which smoulder or burn slowly, i.e. soft furnishings, plastic foam etc. or ‘smoke’ produced by overheated but unburnt PVC. These detectors are particularly suitable for general applications and areas where cable overheating may occur; electrical services areas. The novel design of the asymmetrical sampling chamber and signal processing techniques stop unwanted alarms caused by very small insects. Smoke entering the sampling chamber scatters the infrared light pulses onto a photodiode. These pulses are converted to an electrical signal that is compared against a preset alarm level.</p>
<p>Specifications<br />
&#8211; Operating Voltage 10 to 33Vdc<br />
&#8211; Quiescent Current 60µA<br />
&#8211; Alarm Current (max.)* 0.7 to 67mA (55°C)<br />
0.7 to 60mA (70°C)<br />
&#8211; Alarm State Voltage 2.5 to 7.4V<br />
&#8211; Ext. Powered Load (max.) 50mA. 28Vdc<br />
&#8211; Sensitivity (AS7240.7-2004) 4%Obs/m<br />
&#8211; Remote Indicator E500 Mk2 Series<br />
&#8211; Relative Humidity 10% to 95% (n/cond)<br />
&#8211; Ambient Temperature -20°C to +70°C<br />
&#8211; Dimensions (incl. base) 127 dia x 54H (mm)<br />
&#8211; Weight 188g with base<br />
&#8211; ActivFire Listed afp-1715<br />
&#8211; FPANZ Listed VF/344</p>
<p>*Max. current must be externally limited</p>