<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Detectors Conventional Intrinsically Safe &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/vigilant/detectors-conventional-intrinsically-safe/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:28:45 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Detectors Conventional Intrinsically Safe &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MR601TEX High Performance Optical Intrinsically Safe</title>
		<link>http://fireandsafetywa.com.au/product/mr601tex-high-performance-optical-intrinsically-safe/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mr601tex-high-performance-optical-intrinsically-safe/</guid>
				<description><![CDATA[The MR601TEX has been developed to overcome  the slower response of the optical detectors to hot burning fires, by increasing the sensitivity of the optical detector when it is associated with a rapid change in temperature.]]></description>
								<content:encoded><![CDATA[<p>The MR601TEX has been developed to overcome  the slower response of the optical detectors to hot burning fires, by increasing the sensitivity of the optical detector when it is associated with a rapid change in temperature. In this way it is intended to become a detector which can cover some of the risks currently covered by ion chamber detectors. Smoke detectors will not detect burning alcohol or other clean-burning liquids which do not generate smoke particles. </p>
<p>Specifications<br />
&#8211; Operating Voltage              16 to 28Vdc<br />
&#8211; Operating Current              110 µA (max.)<br />
&#8211; Alarm Current                      30mA @ 16Vdc<br />
&#8211; Operating Temp                  -20°C to +70°C<br />
&#8211; Relative Humidity                95% (non-cond.)<br />
&#8211; Dimensions                        109 dia x 43 H mm<br />
&#8211; Weight                                  128g<br />
&#8211; ATEX Certificate                  BAS01ATEX11134X.<br />
&#8211; IECEX Certificate                BAS 07.0056X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MD611EX Fixed Temperature Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/md611ex-fixed-temperature-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/md611ex-fixed-temperature-heat-detector/</guid>
				<description><![CDATA[Where environmental conditions rule out the use of smoke detectors, MD601Ex/MD611Ex heat detectors may provide an acceptable, though less sensitive, alternative.]]></description>
								<content:encoded><![CDATA[<p>Where environmental conditions rule out the use of smoke detectors, MD601Ex/MD611Ex heat detectors may provide an acceptable, though less sensitive, alternative. For general use (particularly where the ambient temperature may be low) a ‘Rate-of-Rise’  (ROR) heat sensor is preferred. These detectors react to abnormally high rates of change of temperature and provide the fastest response over a wide range of ambient temperatures. A fixed temperature limit is incorporated in these detectors. In kitchens and  boiler rooms etc, sudden, large changes in temperature are considered ‘normal’. Fixed temp. [static] detectors should be used in this case. </p>
<p>Specifications<br />
&#8211; Operating Voltage              16 to 28Vdc<br />
&#8211; Operating Current              100µA (max.)<br />
&#8211; Alarm Current                      5 to 80mA<br />
&#8211; Operating Temp                 -20°C to +70°C<br />
&#8211; Relative Humidity                95% (non-cond.)<br />
&#8211; Dimensions                        109 dia x 43 H mm<br />
&#8211; Weight                                  116g<br />
&#8211; ATEX Certificate                  BAS01ATEX1134X<br />
&#8211; IECEX Certificate                BAS 07.0056X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MD601EX Rate of Rise Heat Detector</title>
		<link>http://fireandsafetywa.com.au/product/md601ex-rate-of-rise-heat-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/md601ex-rate-of-rise-heat-detector/</guid>
				<description><![CDATA[Where environmental conditions rule out the use of smoke detectors, MD601Ex/MD611Ex heat detectors may provide an acceptable, though less sensitive, alternative.]]></description>
								<content:encoded><![CDATA[<p>Where environmental conditions rule out the use of smoke detectors, MD601Ex/MD611Ex heat detectors may provide an acceptable, though less sensitive, alternative. For general use (particularly where the ambient temperature may be low) a ‘Rate-of-Rise’  (ROR) heat sensor is preferred. These detectors react to abnormally high rates of change of temperature and provide the fastest response over a wide range of ambient temperatures. A fixed temperature limit is incorporated in these detectors. In kitchens and  boiler rooms etc, sudden, large changes in temperature are considered ‘normal’. Fixed temp. [static] detectors should be used in this case. </p>
<p>Specifications<br />
&#8211; Operating Voltage              16 to 28Vdc<br />
&#8211; Operating Current              100µA (max.)<br />
&#8211; Alarm Current                      5 to 80mA<br />
&#8211; Operating Temp                 -20°C to +70°C<br />
&#8211; Relative Humidity                95% (non-cond.)<br />
&#8211; Dimensions                        109 dia x 43 H mm<br />
&#8211; Weight                                  116g<br />
&#8211; ATEX Certificate                  BAS01ATEX1134X<br />
&#8211; IECEX Certificate                BAS 07.0056X</p>
]]></content:encoded>
										</item>
		<item>
		<title>MDU601EX Enhanced Heat and Carbon Monoxide Detector</title>
		<link>http://fireandsafetywa.com.au/product/mdu601ex-enhanced-heat-and-carbon-monoxide-detector/</link>
				<pubDate>Sun, 07 Oct 2018 13:28:29 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/mdu601ex-enhanced-heat-and-carbon-monoxide-detector/</guid>
				<description><![CDATA[The MDU601EX detector combines the features of both the MU601EX detector and the MD601EX detector to provide a combined CO and Rate of Rise Heat Detector where the sensitivity of the CO detector is enhanced in response to a fast rate of change of temperature.]]></description>
								<content:encoded><![CDATA[<p>The MDU601EX detector combines the features of both the MU601EX detector and the MD601EX detector to provide a combined CO and Rate of Rise Heat Detector where the sensitivity of the CO detector is enhanced in response to a fast rate of change of temperature. </p>
<p>Specifications<br />
&#8211; Operating Voltage        16 to 28Vdc<br />
&#8211; Operating Current         70 µA (max.)<br />
&#8211; Alarm Current                30mA @ 15Vdc<br />
&#8211; Operating Temp            -20°C to +70°C<br />
&#8211; Relative Humidity          90% (non-cond.)<br />
&#8211; Dimensions                   109 dia x 43 H mm<br />
&#8211; Weight                             126g<br />
&#8211; ATEX Certificate             BAS01ATEX1134X<br />
&#8211; IECEX Certificate           BAS 07.0056X</p>