<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>LaserPlus &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/vesda/laserplus/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Fri, 12 Oct 2018 15:32:18 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>LaserPlus &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>19&#8243; Rack c/w 4 Blanks</title>
		<link>http://fireandsafetywa.com.au/product/19-rack-c-w-4-blanks/</link>
				<pubDate>Sun, 07 Oct 2018 15:26:38 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/19-rack-c-w-4-blanks/</guid>
				<description><![CDATA[To compliment the VESDA range of detectors, displays and programmers in a 19 inch subrack enclosure is available.]]></description>
								<content:encoded><![CDATA[<p>To compliment the VESDA range of detectors, displays and programmers in a 19 inch subrack enclosure is available. The 19 inch rack enclosure is designed to house up to 12 display and/or programmer modules, VESDAnet sockets, or relay only modules<br />
in a wide variety of configurations to suit the particular requirements of a site where centralised control and monitoring of the VESDA system is required. VESDA Aspirating Smoke Detectors (ASD) are available in a wide range of configurations to suit the particular requirements of each site. The system is modular with Display and Programmer Modules located in the most convenient location. The backbone to this modularity is VESDAnet, a fault tolerant RS485 communications loop which links all elements of the VESDA system together.</p>
<p>Mounting Options<br />
Display and Programmer modules can be mounted in a Detector Enclosure, in a Remote Box or in a 19 inch subrack. A Hand-held programmer module is also available for temporary and convenient connection to the VESDA system. Details of these standard mounting options are given in the Detector, Display and Programmer Data sheets.</p>
<p>Relay Signalling<br />
Each Display Module can be configured to drive relays which can be used for reliable (fault tolerant) signalling of Fire and Fault conditions to external systems. Standard Display Modules can drive 7 relays while VESDA VLS Display Modules can be configured to drive 7 or 12 relays. Relay functionality is fully configurable according to site requirements.</p>
<p>19 inch Rack Enclosure<br />
19 inch subracks can be installed in glass fronted enclosures and are mounted on a swing frame for convenient connection of all the cables. Cable entry for 24 VDC power, VESDAnet connection and interfacing to the relays is provided by multiple knock-outs on all four sides of the box. 19 inch subracks and blank panels must be ordered separately. Each enclosure will accommodate up to 3 subracks. If utilising only 1 or 2 racks the VESDA Power Supply (VPS-100-US-xxx) can also be mounted in the enclosure.</p>
<p>Features<br />
&#8211; Dual hinged glass door provides easy access to VESDA modules and termination boards<br />
&#8211; Second door provides access to the termination boards<br />
&#8211; Designed for easy mounting<br />
&#8211; Multiple knock-outs for easy cable entry<br />
&#8211; Holds up to 3 subracks<br />
&#8211; Full size, lockable window and door</p>
<p>Technical Specifications<br />
Construction:<br />
&#8211; NEMA 1 Rating<br />
&#8211; 16 gauge cold roll steel<br />
&#8211; Fully welded and ground<br />
&#8211; Double knockouts<br />
&#8211; Continuous hinges with stainless steel pins<br />
&#8211; Full size window kit – lockable<br />
&#8211; Door – lockable (keyed alike with window)<br />
Mounting: Key hole mounting<br />
Finish: 2-part polyurethane – bake on textured finish<br />
Color: Light grey<br />
Locks: Keyed alike Chicago locks<br />
Blanking Plates:<br />
&#8211; 14 gauge cold roll steel<br />
&#8211; Light grey matching color<br />
&#8211; Single plate – 19 x 51/4 &#8221;<br />
&#8211; Double plate – 19 x 101/2&#8243;<br />
&#8211; Enclosure requires 4 10/32&#8243; screws for mounting 19 inch rack and/or blanking plates</p>
]]></content:encoded>
										</item>
		<item>
		<title>Remote Box with Blank Plate, 12 Relay Card, Driver</title>
		<link>http://fireandsafetywa.com.au/product/remote-box-with-blank-plate-12-relay-card-driver/</link>
				<pubDate>Sun, 07 Oct 2018 13:34:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/remote-box-with-blank-plate-12-relay-card-driver/</guid>
				<description><![CDATA[VESDA Remote Display modules provide real-time indication of the status of a VESDA detector.]]></description>
								<content:encoded><![CDATA[<p>VESDA Remote Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display, a 2 digit numeric display, an audible sounder, clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.  The Display Module can be mounted into a detector unit, a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.  There are various versions of the display module depending on the type of detector and the relay configuration required. The VESDA VLS display has a fourth mode for the Numerical Display which shows the First Alarm Sector (FAS), this being the number of the sector (pipe) that has detected smoke.  For the VESDA VLC the Fire 2 LED is omitted.</p>
<p>Smoke Indication<br />
Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.  The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 1/20 of the Fire 1 smoke threshold level.  To the left of the bar graph are the Fire 1, Action and Alert smoke threshold indicators.  At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to<br />
triggering the next level of alarm.</p>
<p>Status Lights<br />
High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.  Similarly, any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information.  The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified, rectified and the system reset.</p>
<p>Numeric Display<br />
A 2 digit numerical readout has a number of modes that are indicated by up to four LEDs:<br />
&#8211; The current smoke level in % obscuration/m (% obscuration/ft)<br />
&#8211; Fire 1 threshold in % obscuration/m (% obscuration/ft). This is the sensitivity of the detector.<br />
&#8211; The VESDA zone number<br />
&#8211; First Alarm Sector on the VLS display &#8211; the numeric readout shows the sector (pipe) number that has detected smoke.</p>
<p>Push Button Keys<br />
Four large tactile push button keys enable users to reset, isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of it&#8217;s functions.  A lamp test routine is initiated by pressing the Mode key for two seconds.  A Manual Scan can be initiated on the VLS by holding the Silence button for 2 seconds.  </p>
<p>Features:<br />
&#8211; Provides Immediate Status Reporting for a Single VESDA Zone<br />
&#8211; Allows Zone Control of Assigned VESDA Detector<br />
&#8211; High Intensity Alarm LEDs<br />
&#8211; Remote Relay Option<br />
&#8211; 20-Segment Vertical Bar Graph Display<br />
&#8211; Alarm Threshold Indicators<br />
&#8211; Built-In Sounder for Audible Warning<br />
&#8211; Comprehensive Fault Reporting<br />
&#8211; Multi-mode Numeric Display (defaults to smoke obscuration)<br />
&#8211; Recessed Mounting Option</p>
<p>Specifications<br />
Operating Voltage (When used in detector unit, remote unit, or 19&#8243; rack): 18 to 30Vdc<br />
Operating Temp: 0 to 39° C<br />
Relative Humidity: 10 to 95% (non-cond.)</p>
<p>Module Only<br />
Dimensions (HWD): 130x105x30mm<br />
Operating Current: 60mA<br />
Alarm Current: 80mA @24Vdc</p>
<p>Mounted in Remote Box &#8211;<br />
Dimensions (WHD): 140 mm x 150 mm x 85 mm (5.5 in x 5.9 in x 3.4 in)<br />
Operating Current: 90mA<br />
Alarm Current: 110mA @24Vdc</p>
<p>Includes blank plate with a remote mounting box.<br />
7 Relays version for VLS</p>
]]></content:encoded>
										</item>
		<item>
		<title>VSM4 and PSM4 Connection Token (21-100) per token</title>
		<link>http://fireandsafetywa.com.au/product/vsm4-and-psm4-connection-token-21-100-per-token/</link>
				<pubDate>Sun, 07 Oct 2018 13:34:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/vsm4-and-psm4-connection-token-21-100-per-token/</guid>
				<description><![CDATA[Xtralis VSM4 provides full and comprehensive integration of your ASD system, including the VSM4 and PSM4 Connection Token (21-100) per token]]></description>
								<content:encoded><![CDATA[<p>Xtralis VSM4 provides full and comprehensive integration of your VESDA and ICAM smoke and gas detection systems.<br />
VSM4 and PSM4 Connection Token (21-100) per token</p>
]]></content:encoded>
										</item>
		<item>
		<title>Remote Box with VESDA LaserFOCUS, 7 Relays</title>
		<link>http://fireandsafetywa.com.au/product/remote-box-with-vesda-laserfocus-7-relays/</link>
				<pubDate>Sun, 07 Oct 2018 13:34:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/remote-box-with-vesda-laserfocus-7-relays/</guid>
				<description><![CDATA[VESDA Remote Display modules provide real-time indication of the status of a VESDA detector.]]></description>
								<content:encoded><![CDATA[<p>VESDA Remote Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display, a 2 digit numeric display, an audible sounder, clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.  The Display Module can be mounted into a detector unit, a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.  There are various versions of the display module depending on the type of detector and the relay configuration required. The VESDA VLS display has a fourth mode for the Numerical Display which shows the First Alarm Sector (FAS), this being the number of the sector (pipe) that has detected smoke.  For the VESDA VLC the Fire 2 LED is omitted.</p>
<p>Smoke Indication<br />
Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.  The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 1/20 of the Fire 1 smoke threshold level.  To the left of the bar graph are the Fire 1, Action and Alert smoke threshold indicators.  At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to<br />
triggering the next level of alarm.</p>
<p>Status Lights<br />
High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.  Similarly, any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information.  The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified, rectified and the system reset.</p>
<p>Numeric Display<br />
A 2 digit numerical readout has a number of modes that are indicated by up to four LEDs:<br />
&#8211; The current smoke level in % obscuration/m (% obscuration/ft)<br />
&#8211; Fire 1 threshold in % obscuration/m (% obscuration/ft). This is the sensitivity of the detector.<br />
&#8211; The VESDA zone number<br />
&#8211; First Alarm Sector on the VLS display &#8211; the numeric readout shows the sector (pipe) number that has detected smoke.</p>
<p>Push Button Keys<br />
Four large tactile push button keys enable users to reset, isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of it&#8217;s functions.  A lamp test routine is initiated by pressing the Mode key for two seconds.  A Manual Scan can be initiated on the VLS by holding the Silence button for 2 seconds.  </p>
<p>Features:<br />
&#8211; Provides Immediate Status Reporting for a Single VESDA Zone<br />
&#8211; Allows Zone Control of Assigned VESDA Detector<br />
&#8211; High Intensity Alarm LEDs<br />
&#8211; Remote Relay Option<br />
&#8211; 20-Segment Vertical Bar Graph Display<br />
&#8211; Alarm Threshold Indicators<br />
&#8211; Built-In Sounder for Audible Warning<br />
&#8211; Comprehensive Fault Reporting<br />
&#8211; Multi-mode Numeric Display (defaults to smoke obscuration)<br />
&#8211; Recessed Mounting Option</p>
<p>Specifications<br />
Operating Voltage (When used in detector unit, remote unit, or 19&#8243; rack): 18 to 30Vdc<br />
Operating Temp: 0 to 39° C<br />
Relative Humidity: 10 to 95% (non-cond.)</p>
<p>Module Only<br />
Dimensions (HWD): 130x105x30mm<br />
Operating Current: 60mA<br />
Alarm Current: 80mA @24Vdc</p>
<p>Mounted in Remote Box &#8211;<br />
Dimensions (WHD): 140 mm x 150 mm x 85 mm (5.5 in x 5.9 in x 3.4 in)<br />
Operating Current: 90mA<br />
Alarm Current: 110mA @24Vdc</p>
<p>The VRT-V00 is a VESDA LaserFOCUS Display with a remote termination card. 7 Relays.</p>
]]></content:encoded>
										</item>
		<item>
		<title>VSM4 Remote Notification Email / SMS support Per PC</title>
		<link>http://fireandsafetywa.com.au/product/vsm4-remote-notification-email-sms-support-per-pc/</link>
				<pubDate>Sun, 07 Oct 2018 13:34:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/vsm4-remote-notification-email-sms-support-per-pc/</guid>
				<description><![CDATA[Xtralis VSM4 provides full and comprehensive integration of your ASD system, including the VMS4 Remote Notification Email / SMS Support per PC]]></description>
								<content:encoded><![CDATA[<p>Xtralis VSM4 provides full and comprehensive integration of your VESDA and ICAM smoke and gas detection systems.<br />
VMS4 Remote Notification Email / SMS Support per PC</p>
]]></content:encoded>
										</item>
		<item>
		<title>Remote Box with Blank Plate, DRP, 7 Relays</title>
		<link>http://fireandsafetywa.com.au/product/remote-box-with-blank-plate-drp-7-relays/</link>
				<pubDate>Sun, 07 Oct 2018 13:34:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/remote-box-with-blank-plate-drp-7-relays/</guid>
				<description><![CDATA[VESDA Remote Display modules provide real-time indication of the status of a VESDA detector.]]></description>
								<content:encoded><![CDATA[<p>VESDA Remote Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display, a 2 digit numeric display, an audible sounder, clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.  The Display Module can be mounted into a detector unit, a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.  There are various versions of the display module depending on the type of detector and the relay configuration required. The VESDA VLS display has a fourth mode for the Numerical Display which shows the First Alarm Sector (FAS), this being the number of the sector (pipe) that has detected smoke.  For the VESDA VLC the Fire 2 LED is omitted.</p>
<p>Smoke Indication<br />
Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.  The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 1/20 of the Fire 1 smoke threshold level.  To the left of the bar graph are the Fire 1, Action and Alert smoke threshold indicators.  At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to<br />
triggering the next level of alarm.</p>
<p>Status Lights<br />
High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.  Similarly, any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information.  The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified, rectified and the system reset.</p>
<p>Numeric Display<br />
A 2 digit numerical readout has a number of modes that are indicated by up to four LEDs:<br />
&#8211; The current smoke level in % obscuration/m (% obscuration/ft)<br />
&#8211; Fire 1 threshold in % obscuration/m (% obscuration/ft). This is the sensitivity of the detector.<br />
&#8211; The VESDA zone number<br />
&#8211; First Alarm Sector on the VLS display &#8211; the numeric readout shows the sector (pipe) number that has detected smoke.</p>
<p>Push Button Keys<br />
Four large tactile push button keys enable users to reset, isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of it&#8217;s functions.  A lamp test routine is initiated by pressing the Mode key for two seconds.  A Manual Scan can be initiated on the VLS by holding the Silence button for 2 seconds.  </p>
<p>Features:<br />
&#8211; Provides Immediate Status Reporting for a Single VESDA Zone<br />
&#8211; Allows Zone Control of Assigned VESDA Detector<br />
&#8211; High Intensity Alarm LEDs<br />
&#8211; Remote Relay Option<br />
&#8211; 20-Segment Vertical Bar Graph Display<br />
&#8211; Alarm Threshold Indicators<br />
&#8211; Built-In Sounder for Audible Warning<br />
&#8211; Comprehensive Fault Reporting<br />
&#8211; Multi-mode Numeric Display (defaults to smoke obscuration)<br />
&#8211; Recessed Mounting Option</p>
<p>Specifications<br />
Operating Voltage (When used in detector unit, remote unit, or 19&#8243; rack): 18 to 30Vdc<br />
Operating Temp: 0 to 39° C<br />
Relative Humidity: 10 to 95% (non-cond.)</p>
<p>Module Only<br />
Dimensions (HWD): 130x105x30mm<br />
Operating Current: 60mA<br />
Alarm Current: 80mA @24Vdc</p>
<p>Mounted in Remote Box &#8211;<br />
Dimensions (WHD): 140 mm x 150 mm x 85 mm (5.5 in x 5.9 in x 3.4 in)<br />
Operating Current: 90mA<br />
Alarm Current: 110mA @24Vdc</p>
<p>THe VRT-E00 is a VESDA LaserSCANNER with a remote termination card including 7 Relays.<br />
7 Relays version for VLS</p>
]]></content:encoded>
										</item>
		<item>
		<title>Remote Box with LaserCompact Display, 7 Relays</title>
		<link>http://fireandsafetywa.com.au/product/remote-box-with-lasercompact-display-7-relays/</link>
				<pubDate>Sun, 07 Oct 2018 13:34:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/remote-box-with-lasercompact-display-7-relays/</guid>
				<description><![CDATA[VESDA Remote Display modules provide real-time indication of the status of a VESDA detector.]]></description>
								<content:encoded><![CDATA[<p>VESDA Remote Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display, a 2 digit numeric display, an audible sounder, clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.  The Display Module can be mounted into a detector unit, a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.  There are various versions of the display module depending on the type of detector and the relay configuration required. The VESDA VLS display has a fourth mode for the Numerical Display which shows the First Alarm Sector (FAS), this being the number of the sector (pipe) that has detected smoke.  For the VESDA VLC the Fire 2 LED is omitted.</p>
<p>Smoke Indication<br />
Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.  The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 1/20 of the Fire 1 smoke threshold level.  To the left of the bar graph are the Fire 1, Action and Alert smoke threshold indicators.  At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to<br />
triggering the next level of alarm.</p>
<p>Status Lights<br />
High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.  Similarly, any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information.  The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified, rectified and the system reset.</p>
<p>Numeric Display<br />
A 2 digit numerical readout has a number of modes that are indicated by up to four LEDs:<br />
&#8211; The current smoke level in % obscuration/m (% obscuration/ft)<br />
&#8211; Fire 1 threshold in % obscuration/m (% obscuration/ft). This is the sensitivity of the detector.<br />
&#8211; The VESDA zone number<br />
&#8211; First Alarm Sector on the VLS display &#8211; the numeric readout shows the sector (pipe) number that has detected smoke.</p>
<p>Push Button Keys<br />
Four large tactile push button keys enable users to reset, isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of it&#8217;s functions.  A lamp test routine is initiated by pressing the Mode key for two seconds.  A Manual Scan can be initiated on the VLS by holding the Silence button for 2 seconds.  </p>
<p>Features:<br />
&#8211; Provides Immediate Status Reporting for a Single VESDA Zone<br />
&#8211; Allows Zone Control of Assigned VESDA Detector<br />
&#8211; High Intensity Alarm LEDs<br />
&#8211; Remote Relay Option<br />
&#8211; 20-Segment Vertical Bar Graph Display<br />
&#8211; Alarm Threshold Indicators<br />
&#8211; Built-In Sounder for Audible Warning<br />
&#8211; Comprehensive Fault Reporting<br />
&#8211; Multi-mode Numeric Display (defaults to smoke obscuration)<br />
&#8211; Recessed Mounting Option</p>
<p>Specifications<br />
Operating Voltage (When used in detector unit, remote unit, or 19&#8243; rack): 18 to 30Vdc<br />
Operating Temp: 0 to 39° C<br />
Relative Humidity: 10 to 95% (non-cond.)</p>
<p>Module Only<br />
Dimensions (HWD): 130x105x30mm<br />
Operating Current: 60mA<br />
Alarm Current: 80mA @24Vdc</p>
<p>Mounted in Remote Box &#8211;<br />
Dimensions (WHD): 140 mm x 150 mm x 85 mm (5.5 in x 5.9 in x 3.4 in)<br />
Operating Current: 90mA<br />
Alarm Current: 110mA @24Vdc</p>
<p>The CRT-J00 is a VESDA VLC Display with a remote termination card. 7 Relays.</p>
]]></content:encoded>
										</item>
		<item>
		<title>Remote Box with VESDA VLI Display, 7 Relays</title>
		<link>http://fireandsafetywa.com.au/product/remote-box-with-vesda-vli-display-7-relays/</link>
				<pubDate>Sun, 07 Oct 2018 13:34:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/remote-box-with-vesda-vli-display-7-relays/</guid>
				<description><![CDATA[VESDA Remote Display modules provide real-time indication of the status of a VESDA detector.]]></description>
								<content:encoded><![CDATA[<p>VESDA Remote Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display, a 2 digit numeric display, an audible sounder, clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.  The Display Module can be mounted into a detector unit, a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.  There are various versions of the display module depending on the type of detector and the relay configuration required. The VESDA VLS display has a fourth mode for the Numerical Display which shows the First Alarm Sector (FAS), this being the number of the sector (pipe) that has detected smoke.  For the VESDA VLC the Fire 2 LED is omitted.</p>
<p>Smoke Indication<br />
Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.  The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 1/20 of the Fire 1 smoke threshold level.  To the left of the bar graph are the Fire 1, Action and Alert smoke threshold indicators.  At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to<br />
triggering the next level of alarm.</p>
<p>Status Lights<br />
High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.  Similarly, any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information.  The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified, rectified and the system reset.</p>
<p>Numeric Display<br />
A 2 digit numerical readout has a number of modes that are indicated by up to four LEDs:<br />
&#8211; The current smoke level in % obscuration/m (% obscuration/ft)<br />
&#8211; Fire 1 threshold in % obscuration/m (% obscuration/ft). This is the sensitivity of the detector.<br />
&#8211; The VESDA zone number<br />
&#8211; First Alarm Sector on the VLS display &#8211; the numeric readout shows the sector (pipe) number that has detected smoke.</p>
<p>Push Button Keys<br />
Four large tactile push button keys enable users to reset, isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of it&#8217;s functions.  A lamp test routine is initiated by pressing the Mode key for two seconds.  A Manual Scan can be initiated on the VLS by holding the Silence button for 2 seconds.  </p>
<p>Features:<br />
&#8211; Provides Immediate Status Reporting for a Single VESDA Zone<br />
&#8211; Allows Zone Control of Assigned VESDA Detector<br />
&#8211; High Intensity Alarm LEDs<br />
&#8211; Remote Relay Option<br />
&#8211; 20-Segment Vertical Bar Graph Display<br />
&#8211; Alarm Threshold Indicators<br />
&#8211; Built-In Sounder for Audible Warning<br />
&#8211; Comprehensive Fault Reporting<br />
&#8211; Multi-mode Numeric Display (defaults to smoke obscuration)<br />
&#8211; Recessed Mounting Option</p>
<p>Specifications<br />
Operating Voltage (When used in detector unit, remote unit, or 19&#8243; rack): 18 to 30Vdc<br />
Operating Temp: 0 to 39° C<br />
Relative Humidity: 10 to 95% (non-cond.)</p>
<p>Module Only<br />
Dimensions (HWD): 130x105x30mm<br />
Operating Current: 60mA<br />
Alarm Current: 80mA @24Vdc</p>
<p>Mounted in Remote Box &#8211;<br />
Dimensions (WHD): 140 mm x 150 mm x 85 mm (5.5 in x 5.9 in x 3.4 in)<br />
Operating Current: 90mA<br />
Alarm Current: 110mA @24Vdc</p>
<p>The VRT-Q00 is a VESDA LaserINDUSTRIAL display with a remote termination card. 7 Relays.</p>
]]></content:encoded>
										</item>
		<item>
		<title>Remote Box with VESDA VLI Display No Relays</title>
		<link>http://fireandsafetywa.com.au/product/remote-box-with-vesda-vli-display-no-relays/</link>
				<pubDate>Sun, 07 Oct 2018 13:34:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/remote-box-with-vesda-vli-display-no-relays/</guid>
				<description><![CDATA[VESDA Remote Display modules provide real-time indication of the status of a VESDA detector.]]></description>
								<content:encoded><![CDATA[<p>VESDA Remote Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display, a 2 digit numeric display, an audible sounder, clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.  The Display Module can be mounted into a detector unit, a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.  There are various versions of the display module depending on the type of detector and the relay configuration required. The VESDA VLS display has a fourth mode for the Numerical Display which shows the First Alarm Sector (FAS), this being the number of the sector (pipe) that has detected smoke.  For the VESDA VLC the Fire 2 LED is omitted.</p>
<p>Smoke Indication<br />
Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.  The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 1/20 of the Fire 1 smoke threshold level.  To the left of the bar graph are the Fire 1, Action and Alert smoke threshold indicators.  At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to<br />
triggering the next level of alarm.</p>
<p>Status Lights<br />
High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.  Similarly, any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information.  The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified, rectified and the system reset.</p>
<p>Numeric Display<br />
A 2 digit numerical readout has a number of modes that are indicated by up to four LEDs:<br />
&#8211; The current smoke level in % obscuration/m (% obscuration/ft)<br />
&#8211; Fire 1 threshold in % obscuration/m (% obscuration/ft). This is the sensitivity of the detector.<br />
&#8211; The VESDA zone number<br />
&#8211; First Alarm Sector on the VLS display &#8211; the numeric readout shows the sector (pipe) number that has detected smoke.</p>
<p>Push Button Keys<br />
Four large tactile push button keys enable users to reset, isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of it&#8217;s functions.  A lamp test routine is initiated by pressing the Mode key for two seconds.  A Manual Scan can be initiated on the VLS by holding the Silence button for 2 seconds.  </p>
<p>Features:<br />
&#8211; Provides Immediate Status Reporting for a Single VESDA Zone<br />
&#8211; Allows Zone Control of Assigned VESDA Detector<br />
&#8211; High Intensity Alarm LEDs<br />
&#8211; Remote Relay Option<br />
&#8211; 20-Segment Vertical Bar Graph Display<br />
&#8211; Alarm Threshold Indicators<br />
&#8211; Built-In Sounder for Audible Warning<br />
&#8211; Comprehensive Fault Reporting<br />
&#8211; Multi-mode Numeric Display (defaults to smoke obscuration)<br />
&#8211; Recessed Mounting Option</p>
<p>Specifications<br />
Operating Voltage (When used in detector unit, remote unit, or 19&#8243; rack): 18 to 30Vdc<br />
Operating Temp: 0 to 39° C<br />
Relative Humidity: 10 to 95% (non-cond.)</p>
<p>Module Only<br />
Dimensions (HWD): 130x105x30mm<br />
Operating Current: 60mA<br />
Alarm Current: 80mA @24Vdc</p>
<p>Mounted in Remote Box &#8211;<br />
Dimensions (WHD): 140 mm x 150 mm x 85 mm (5.5 in x 5.9 in x 3.4 in)<br />
Operating Current: 90mA<br />
Alarm Current: 110mA @24Vdc</p>
<p>The VRT-T00 is a VESDA LaserINDUSTRIAL display with a remote termination card. No Relays.</p>
]]></content:encoded>
										</item>
		<item>
		<title>LaserPLUS Handheld Programmer c/w Cable</title>
		<link>http://fireandsafetywa.com.au/product/laserplus-handheld-programmer-c-w-cable/</link>
				<pubDate>Sun, 07 Oct 2018 13:34:42 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/laserplus-handheld-programmer-c-w-cable/</guid>
				<description><![CDATA[The LaserPLUS Handheld Programmer including a lead for temporary connection of a programmer to a network via a VESDAnet socket.]]></description>
								<content:encoded><![CDATA[<p>The LaserPLUS Handheld Programmer Module allows direct access to all VESDAnet devices on a VESDA smoke detection system.  It allows configuration and status reporting of detectos, displays and interfaces and is required when installing, commissioning and maintaining a VESDA network.  By incorporating a user friendly menu, navigation through the comprehensive features of VESDAnet is convenient and simple.</p>
<p>The VESDA LCD hand held Programmer including a lead for temporary connection of a programmer to a network via a VESDAnet socket.</p>
<p>Specifications<br />
Dimensions: 105x135x60mm<br />
Screen Display Size: 70x37mm<br />
Supply Voltage: 18 &#8211; 30Vdc<br />
Power (W) @24VDC: 1.68<br />
Current (mA) @24VDC: 70mA</p>