<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Detectors &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/vesda/laserfocus/detectors-laserfocus/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:32:43 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Detectors &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>VESDAnet Interface (VN) Card</title>
		<link>http://fireandsafetywa.com.au/product/vesdanet-interface-vn-card/</link>
				<pubDate>Sun, 07 Oct 2018 13:32:38 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/vesdanet-interface-vn-card/</guid>
				<description><![CDATA[The VESDAnet Interface Card (VN Card) is a simple interface card for the range of VESDA VLF by Xtralis aspirating smoke detectors.]]></description>
								<content:encoded><![CDATA[<p>The VESDAnet Interface Card (VN Card) is a simple interface card for the range of VESDA VLF by Xtralis aspirating smoke detectors. The VN Card provides seamless VESDAnet communication from the detector to other VESDAnet devices, including configuration and monitoring tools.</p>
<p>Installing a VESDAnet Interface Card into a VLF detector and connecting to a VESDAnet offers many benefits.  VESDAnet allows sophisticated configuration, monitoring and control from local or remote sites. So rather than a technician having to connect to each<br />
VESDA smoke detector individually (sometimes installed high above floor level), they can communicate with all detectors on the network from a central, convenient, location using a PC.  VESDAnet also allows a system management package (such as Xtralis<br />
VSM4) to monitor and report on the status of all devices connected on VESDAnet, facilitating central supervision, management and control of all VESDA detectors.  By installing a VN Card in a VLF detector, remote displays and remote relays can be added to the VLF.  This extends the capability and flexibility of the VLF detector.</p>
<p>Features<br />
&#8211; Provides seamless VESDAnet fault-tolerant communication<br />
&#8211; Quick and simple to install<br />
&#8211; Minimal configuration required<br />
&#8211; Diagnostic LEDs give visual indication of the card’s status<br />
&#8211; Fully transferrable between Xtralis VESDA VLF detectors</p>
<p>Specifications<br />
Power Consumption:  Consumes less than 1 W from the detector at 24 VDC &#038; 42 mA.<br />
Dimensions (LxWxH):  137 mm (5¼”) x 71 mm (2 13/16”) x 20 mm (13/16”)<br />
Weight:  0.08 kg (0.176 lb)<br />
Terminals:  0.2 &#8211; 2.5 mm2  (30-12 AWG)<br />
Operating Conditions<br />
Tested to:  -10 to 55°C (14 to 131°F)<br />
Detector Ambient:  0 to 40°C (32 to 104°F)<br />
Humidity:  5% to 95% (non-condensing)</p>
]]></content:encoded>
										</item>
		<item>
		<title>VESDA LaserFOCUS Relay Expansion Card</title>
		<link>http://fireandsafetywa.com.au/product/vesda-laserfocus-relay-expansion-card/</link>
				<pubDate>Sun, 07 Oct 2018 13:32:38 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/vesda-laserfocus-relay-expansion-card/</guid>
				<description><![CDATA[The VESDA LaserFOCUS Relay Expansion Card is an interface card for the range of Xtralis VESDA VLF smoke detectors. A Relay Expansion Card explands the range of input and outup communications a VLF can perform.]]></description>
								<content:encoded><![CDATA[<p>The VESDA LaserFOCUS Relay Expansion Card is an interface card for the range of Xtralis VESDA VLF smoke detectors. An LaserFOCUS Relay Expansion Card expands the rangeof input and output communications a VLF detector can perform.</p>
<p>Installing a VLF LaserFOCUS Relay Expansion Card into a VLF detector provides enhanced benefits and a cost-effective solution for customers who need enhanced connectivity, fault detection and monitoring, and annunciation of alarms and faults. The principal benefits include:<br />
&#8211; Improved FACP Connectivity: The VLF is fitted with two (2) alarm relays in its standard form. With an extra two (2) relays, the Multi-function Control Card allows reporting of all four (4) alarm levels on dry relay outputs.<br />
&#8211; Enhanced Annunciation: An MPO (Monitored 24 V Powered Output) is available on the VLF LaserFOCUS Relay Expansion Card.  The MPO provides power to devices such as sirens or strobes, and monitors the line integrity.</p>
<p>Features<br />
&#8211; Provides two (2) additional relays<br />
&#8211; Provides an extra General Purpose Input (GPI) with line monitoring<br />
&#8211; Quick and simple to install<br />
&#8211; Out-of-the-box operation, with minimal configuration required for extra features<br />
&#8211; Diagnostic LEDs give visual indication of the card’s status<br />
&#8211; Fully compatible with Xtralis VESDA VLF smoke detectors</p>
<p>Specifications<br />
Dimensions<br />
Length x Width x Height 110 mm (41/3”) x 70 mm (2 3/4”) x 20 mm (13/16”)<br />
Weight 0.08 kg (0.176 lb)<br />
Terminals 0.2 &#8211; 2.5 mm2 (30-12 AWG)</p>
]]></content:encoded>
										</item>
		<item>
		<title>VLF 3 Relay &#038; 1 Input Multifunction Control Card</title>
		<link>http://fireandsafetywa.com.au/product/vlf-3-relay-1-input-multifunction-control-card/</link>
				<pubDate>Sun, 07 Oct 2018 13:32:38 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/vlf-3-relay-1-input-multifunction-control-card/</guid>
				<description><![CDATA[The VESDA LaserFOCUS Relay Multifuction Control Card is an interface card for the range of Xtralis VESDA VLF smoke detectors.  A MCC expands the range of input and output communications a VLF detector can perform.]]></description>
								<content:encoded><![CDATA[<p>The VESDA LaserFOCUS Relay Multifuction Control Card is an interface card for the range of Xtralis VESDA VLF smoke detectors. </p>
<p>Installing a VLF LaserFOCUS Relay Multifuction Control Card detector provides enhanced benefits and a cost-effective solution for customers who need enhanced connectivity, fault detection and monitoring, and annunciation of alarms and faults. The principal benefits include:<br />
&#8211; Improved FACP Connectivity: The VLF is fitted with two (2) alarm relays in its standard form. With an extra two (2) relays, the Multi-function Control Card allows reporting of all four (4) alarm levels on dry relay outputs.<br />
&#8211; Enhanced Annunciation: An MPO (Monitored 24 V Powered Output) is available on the VLF LaserFOCUS Relay Multifuction Control Card.  The MPO provides power to devices such as sirens or strobes, and monitors the line integrity.<br />
&#8211; Enhanced Control and Fault Detection: With a VLF MCC installed, a VLF has two (2) General Purpose Inputs (GPIs), allowing, for example, one GPI to report on loss of mains power and the other GPI to be used as a reset input.</p>
<p>Features<br />
&#8211; Provides two (2) additional relays<br />
&#8211; Provides an extra General Purpose Input (GPI) with line monitoring<br />
&#8211; Quick and simple to install<br />
&#8211; Out-of-the-box operation, with minimal configuration required for extra features<br />
&#8211; Diagnostic LEDs give visual indication of the card’s status<br />
&#8211; Fully compatible with Xtralis VESDA VLF smoke detectors<br />
&#8211; Selection between 3rd relay or 24 V Monitored Powered Output (MPO)</p>
<p>Specifications<br />
Dimensions<br />
Length x Width x Height 110 mm (41/3”) x 70 mm (2 3/4”) x 20 mm (13/16”)<br />
Weight 0.08 kg (0.176 lb)<br />
Terminals 0.2 &#8211; 2.5 mm2 (30-12 AWG)</p>
]]></content:encoded>
										</item>
		<item>
		<title>VESDA LaserFOCUS VESDAnet Compatible For 500m²</title>
		<link>http://fireandsafetywa.com.au/product/vesda-laserfocus-vesdanet-compatible-for-500m%c2%b2/</link>
				<pubDate>Sun, 07 Oct 2018 13:32:09 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/vesda-laserfocus-vesdanet-compatible-for-500m%c2%b2/</guid>
				<description><![CDATA[The VESDA LaserFOCUS early warning air sampling smoke detector incorporates world leading VESDA very early warning laser based aspirated smoke detection technology.]]></description>
								<content:encoded><![CDATA[<p>The VESDA LaserFOCUS early warning air sampling smoke detector incorporates world leading VESDA very early warning laser based aspirated smoke detection technology. It provides<br />
localized fire risk management solutions for small, critical environments. The VESDA LaserFOCUS VLF-500 monitors areas up to 500 m2 (5000 sq. ft.), dependant on local codes and standards. The VESDA LaserFOCUS complements the existing VESDA detector range and has been designed to provide simple installation and commissioning, absolute smoke detection and reliable and consistent response to smoke events without being affected by false alarms.</p>
<p>The Relays Only model  is used as a single stand-alone smoke detecor and is not connected into VESDAnet.  Programming this detector is by connecting to a PC with a RS232 communication cable to the 9-pin programming socket on the termination card located inside the detector. </p>
<p>The VESDAnet model is used when the detector is to connected into VESDAnet.  This detector can be used as a stand-alone device and not connected into VESDAnet as well.</p>
<p>Specifications<br />
&#8211; Dimensions        256 x 183 x 92 mm<br />
&#8211; Weight                 2kg<br />
&#8211; Area Coverage   250m2</p>
]]></content:encoded>
										</item>
		<item>
		<title>VESDA LaserFOCUS Relays Only</title>
		<link>http://fireandsafetywa.com.au/product/vesda-laserfocus-relays-only/</link>
				<pubDate>Sun, 07 Oct 2018 13:32:09 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/vesda-laserfocus-relays-only/</guid>
				<description><![CDATA[The VESDA LaserFOCUS early warning air sampling smoke detector incorporates world leading VESDA very early warning laser based aspirated smoke detection technology.]]></description>
								<content:encoded><![CDATA[<p>The VESDA LaserFOCUS early warning air sampling smoke detector incorporates world leading VESDA very early warning laser based aspirated smoke detection technology. It provides localized fire risk management solutions for small, critical environments. The VESDA LaserFOCUS VLF-250 monitors areas up to 250 m2 (2500 sq. ft.), dependant on local codes and standards. The VESDA LaserFOCUS complements the existing VESDA detector range and has been designed to provide simple installation and commissioning, absolute smoke detection and reliable and consistent response to smoke events without being affected by false alarms.</p>
<p>The Relays Only model  is used as a single stand-alone smoke detecor and is not connected into VESDAnet.  Programming this detector is by connecting to a PC with a RS232 communication cable to the 9-pin programming socket on the termination card located inside the detector. </p>
<p>The VESDAnet model is used when the detector is to connected into VESDAnet.  This detector can be used as a stand-alone device and not connected into VESDAnet as well.</p>
<p>Specifications<br />
&#8211; Dimensions        256 x 183 x 92 mm<br />
&#8211; Weight                 2kg<br />
&#8211; Area Coverage   250m2</p>