<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MAPNET / IDNET Addressable Bases &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/simplex/mapnet-idnet-addressable-bases/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:31:46 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.16</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>MAPNET / IDNET Addressable Bases &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TrueAlarm Base with Remote LED O/P</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</guid>
				<description><![CDATA[TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds.]]></description>
								<content:encoded><![CDATA[<p>TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds. Since TrueAlarm detectors use the same base, different detector types can be easily interchanged to meet specific location requirements, for example, during building construction, or when conditions are temporarily dusty. Instead of covering the smoke  detectors(causing them to be disabled), heat detectors may be installed without reprogramming the CIE. Although the CIE will indicate an incorrect detector type, the heat detector will operate at a default sensitivity maintaining building protection at that location. </p>
<p>The 4098-9789EAP can be used in areas that may experience an increased moisture level, eg under eaves</p>
<p>Specifications<br />
&#8211; Operating Voltage                   24 to 40Vdc*<br />
&#8211; Quiescent Current (max)       400µA<br />
&#8211; Alarm Current (max)               3.2mA<br />
&#8211; Relative Humidity                    10% to 95% (n/cond)<br />
&#8211; Ambient Temperature             0 to +55°C<br />
&#8211; ActivFire Listed                         afp-1225 &#038; 1246</p>
<p>* MAPNET II or IDNet auto select</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm Base with Sounder</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</guid>
				<description><![CDATA[The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics.]]></description>
								<content:encoded><![CDATA[<p>The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics. Used in  conjunction with the Simplex 4100 panel, the 9714E has a high degree of false alarm immunity thanks to advanced algorithms. The detector mounts on the 4098-9789 addressable base or 4098-9794 sounder base. An optional remote LED can also be fitted.</p>
<p>Specifications<br />
&#8211; Operating Voltage                      24 to 40Vdc*<br />
&#8211; Quiescent Current (max)          100µA<br />
&#8211; Alarm Current-relay active         24mA<br />
&#8211; External Output Drive (max)      5mA<br />
&#8211; Relative Humidity                        10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                -9°C to +50°C<br />
&#8211; Air Velocity                                    0 to 610m/min<br />
&#8211; Sensitivity                                      4 to 6% Obs/m<br />
&#8211; ActivFire Listed                            afp-1225</p>
<p>* MAPNET II or IDNet auto select w/data</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm IDNET Isolator Base</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-idnet-isolator-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-idnet-isolator-base/</guid>
				<description><![CDATA[The 4098-9793 isolator base accepts Simplex TrueAlarm analog sensors and provides communications isolation to improve installation convenience and increase system integrity.]]></description>
								<content:encoded><![CDATA[<p>The 4098-9793 isolator base accepts Simplex TrueAlarm analog sensors and provides communications isolation to improve installation convenience and increase system integrity. An internal isolation relay allows a compatible c.i.e. to separate shorted  communications wiring from functioning wiring to optimise the available sensors or other IDNet addressable devices. The isolator base’s status is communicated to the FIP,  allowing it to assist in identifying the location of the shorted wiring. During installation, earth faults frequently occur. Finding these faults normally requires extensive wiring disconnection. With the  4098-9793 isolator base, earth faults on the IDNet communications lines can be quickly located to assist in their repair and to restore the system wiring<br />
to normal.</p>
<p>Specifications<br />
&#8211; Operating Voltage                            24 to 40Vdc*<br />
&#8211; Input Voltage                                     18.9 to 32Vdc<br />
&#8211; Current (max.@ 24Vdc)                  500µA<br />
&#8211; Supervisory Resistor (9101)          3k3 Ohm 1W<br />
&#8211; Dimensions (HWD)                         105 x 105 x 35mm<br />
&#8211; Relative Humidity                              10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                       -9°C to +50°C</p>
<p>* IDNet, 1 address per base</p>