<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Simplex &#8211; Fire &amp; Safety WA</title>
	<atom:link href="http://fireandsafetywa.com.au/product-category/fire-detection/simplex/feed/" rel="self" type="application/rss+xml" />
	<link>http://fireandsafetywa.com.au</link>
	<description></description>
	<lastBuildDate>Sun, 07 Oct 2018 13:32:06 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.21</generator>

<image>
	<url>http://fireandsafetywa.com.au/wp-content/uploads/2018/04/cropped-favicon-32x32.png</url>
	<title>Simplex &#8211; Fire &amp; Safety WA</title>
	<link>http://fireandsafetywa.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Addressable MCP Mounting Box</title>
		<link>http://fireandsafetywa.com.au/product/addressable-mcp-mounting-box/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/addressable-mcp-mounting-box/</guid>
				<description><![CDATA[Red surface mounting back box (for indoor callpoints) with terminals fitted.]]></description>
								<content:encoded><![CDATA[<p>Red surface mounting back box (for indoor callpoints) with terminals fitted.</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Roof Space&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-roof-space/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-roof-space/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Concealed Space&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-concealed-space/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-concealed-space/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Cupboard&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-cupboard/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-cupboard/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Room&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-room/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-room/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm Base with Remote LED O/P</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-remote-led-o-p/</guid>
				<description><![CDATA[TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds.]]></description>
								<content:encoded><![CDATA[<p>TrueAlarm detector bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionisation, or heat detectors. Each detector’s output is digitised and transmitted to the system CIE every four seconds. Since TrueAlarm detectors use the same base, different detector types can be easily interchanged to meet specific location requirements, for example, during building construction, or when conditions are temporarily dusty. Instead of covering the smoke  detectors(causing them to be disabled), heat detectors may be installed without reprogramming the CIE. Although the CIE will indicate an incorrect detector type, the heat detector will operate at a default sensitivity maintaining building protection at that location. </p>
<p>The 4098-9789EAP can be used in areas that may experience an increased moisture level, eg under eaves</p>
<p>Specifications<br />
&#8211; Operating Voltage                   24 to 40Vdc*<br />
&#8211; Quiescent Current (max)       400µA<br />
&#8211; Alarm Current (max)               3.2mA<br />
&#8211; Relative Humidity                    10% to 95% (n/cond)<br />
&#8211; Ambient Temperature             0 to +55°C<br />
&#8211; ActivFire Listed                         afp-1225 &#038; 1246</p>
<p>* MAPNET II or IDNet auto select</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `Return Air&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-return-air/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-return-air/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm Base with Sounder</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-base-with-sounder/</guid>
				<description><![CDATA[The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics.]]></description>
								<content:encoded><![CDATA[<p>The 4098-9714EA Photoelectric smoke detector contains a state-of-the-art sensing chamber and analogue communication electronics. Used in  conjunction with the Simplex 4100 panel, the 9714E has a high degree of false alarm immunity thanks to advanced algorithms. The detector mounts on the 4098-9789 addressable base or 4098-9794 sounder base. An optional remote LED can also be fitted.</p>
<p>Specifications<br />
&#8211; Operating Voltage                      24 to 40Vdc*<br />
&#8211; Quiescent Current (max)          100µA<br />
&#8211; Alarm Current-relay active         24mA<br />
&#8211; External Output Drive (max)      5mA<br />
&#8211; Relative Humidity                        10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                -9°C to +50°C<br />
&#8211; Air Velocity                                    0 to 610m/min<br />
&#8211; Sensitivity                                      4 to 6% Obs/m<br />
&#8211; ActivFire Listed                            afp-1225</p>
<p>* MAPNET II or IDNet auto select w/data</p>
]]></content:encoded>
										</item>
		<item>
		<title>SIMPLEX Remote LED Mapnet `In Duct&#8217;</title>
		<link>http://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-in-duct/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/simplex-remote-led-mapnet-in-duct/</guid>
				<description><![CDATA[The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module.]]></description>
								<content:encoded><![CDATA[<p>The 2098-1xxx range of remote indicators provide remote indication of an alarm condition on a detector fixed on a 4098-97xx detector base. These remote indicators are not suitable for connection to any other MAPNET II or IDNet module. They are used where the fire detector is installed in an inaccessible location, and indication of alarm must be provided in an easily accessible area. For example, where the detectors are in roof spaces or cupboards, under the floor, or in hotel rooms, and indication is required in the room or corridor.</p>
<p>Specifications<br />
&#8211; Operating Voltage              1.8Vdc Typ.<br />
                                                 (from 4098-97xx Base)<br />
&#8211; Alarm Current (min.)         1.6mA<br />
&#8211; Alarm Current (max.)         25mA@45°C<br />
                                                 15mA@75°C<br />
&#8211; Luminous Intensity            as per AS2362.25<br />
&#8211; Relative Humidity               10% to 95% (n/cond)<br />
&#8211; Ambient Temperature        -5°C to +75°C</p>
]]></content:encoded>
										</item>
		<item>
		<title>TrueAlarm IDNET Isolator Base</title>
		<link>http://fireandsafetywa.com.au/product/truealarm-idnet-isolator-base/</link>
				<pubDate>Sun, 07 Oct 2018 13:31:41 +0000</pubDate>
		<dc:creator><![CDATA[AJBPIKE]]></dc:creator>
		
		<guid isPermaLink="false">https://fireandsafetywa.com.au/product/truealarm-idnet-isolator-base/</guid>
				<description><![CDATA[The 4098-9793 isolator base accepts Simplex TrueAlarm analog sensors and provides communications isolation to improve installation convenience and increase system integrity.]]></description>
								<content:encoded><![CDATA[<p>The 4098-9793 isolator base accepts Simplex TrueAlarm analog sensors and provides communications isolation to improve installation convenience and increase system integrity. An internal isolation relay allows a compatible c.i.e. to separate shorted  communications wiring from functioning wiring to optimise the available sensors or other IDNet addressable devices. The isolator base’s status is communicated to the FIP,  allowing it to assist in identifying the location of the shorted wiring. During installation, earth faults frequently occur. Finding these faults normally requires extensive wiring disconnection. With the  4098-9793 isolator base, earth faults on the IDNet communications lines can be quickly located to assist in their repair and to restore the system wiring<br />
to normal.</p>
<p>Specifications<br />
&#8211; Operating Voltage                            24 to 40Vdc*<br />
&#8211; Input Voltage                                     18.9 to 32Vdc<br />
&#8211; Current (max.@ 24Vdc)                  500µA<br />
&#8211; Supervisory Resistor (9101)          3k3 Ohm 1W<br />
&#8211; Dimensions (HWD)                         105 x 105 x 35mm<br />
&#8211; Relative Humidity                              10% to 95% (n/cond)<br />
&#8211; Ambient Temperature                       -9°C to +50°C</p>
<p>* IDNet, 1 address per base</p>
]]></content:encoded>
										</item>
	</channel>
</rss>
